Literature DB >> 32845385

A Novel Non-contact Self-Injection-Locked Radar for Vital Sign Sensing and Body Movement Monitoring in COVID-19 Isolation Ward.

Cheng-Yu Tsai1,2, Nai-Chien Chang3, Hsiu-Chen Fang3, Ying-Che Chen4, Su-Shin Lee5,6,7.   

Abstract

BACKGROUND: The outbreak of Coronavirus disease (COVID-19) pandemic has become the most serious global health issue. Isolation policy in hospitals is one of the most crucial protocols to prevent nosocomial infection of COVID-19. It is important to monitor and assess the physical conditions of the patients in isolation.
METHODS: Our institution has installed the novel non-contact wireless sensor for vital sign sensing and body movement monitoring for patients in COVID-19 isolation ward.
RESULTS: We have collected and compared data between the radar record with the nurse's handover record of two patients, one recorded for 13 days and the other recorded for 5 days. The P value by Fisher's exact test were 0.139 (temperature, P > 0.05) and 0.292 (heart beat rate, P > 0.05) respectively.
CONCLUSIONS: This is the first report about the application experience of this equipment. Therefore we attempted to share the experience and try to apply this equipment in COVID-19 patients in future to offer the more reliable and safe policy.

Entities:  

Keywords:  Coronavirus disease; Self-injection-locked radar; Vital sign sensing

Mesh:

Year:  2020        PMID: 32845385      PMCID: PMC7447692          DOI: 10.1007/s10916-020-01637-z

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


Background

As Coronavirus disease 2019 (COVID-19) spreads across the world, the COVID-19 pandemic has become the most serious global health issue and caused huge impacts on healthcare systems. Since COVID-19 is extremely transmissible, the clinical features are non-specific and cannot be easily distinguished from other causes of severe community-acquired pneumonia. [1] The healthcare industry is suffering from the surge of COVID-19, and carrying the risks of being overwhelmed by the pandemic. For example, there is a potential risk of nosocomial transmission due to the viable virus remained on personal protective equipment (PPE) used by the healthcare staff. Zamora et al. has reported a substantial risk of self-contamination when doffing PPE. [2] In addition, since there is a higher risk of being infected or in quarantine caused by the exposure to COVID-19 from improper protections, hospital staff’s morale is highly affected. Therefore, we shall utilize the new technology to protect the healthcare staff as well as maintaining proper health care service quality to the publics. In this report, we introduce a non-contact self-injection-locked radar (SIL Radar Technology INC., Kaohsiung, Taiwan). The SIL Oscillator’s output signal is received and demodulated by a remote frequency discriminator to obtain the pulse rate information. [3] It can provide the information for vital signs and large body movements of the patient. This instrument has been used on COVID-19 patients as an auxiliary monitor system in the isolation ward.

Methods

The non-contact wireless sensor has been fixed on the ceiling of the ward. It detects and records the vital signs of the patient every five seconds automatically without physical contacts between the patient and healthcare staff. There have been several engineering research articles of the device presented by the inventors. The technologies of self-injection-locked radar and infrared light are used in non-contact detection of vital signs, included body temperature, heart rate, respiratory rate and body positioning [3-7]. As more information is collected, the software of this device is able to conduct an auto-calibration to extract the displacement information, which enhances the measurement accuracy of body temperature, heart rate and respiratory rate. [5]

Results

We have collected and compared data between the radar record with the nurse’s handover record of two patients, one recorded for 13 days and the other recorded for 5 days. The P value by Fisher’s exact test were 0.139 (temperature, P > 0.05) and 0.292 (heart beat rate, P > 0.05) respectively. In addition, the device can detect the human face and body movement to identify actual positions of the patient, such as lying on the bed or falling down on the floor in the ward. [8] The device has performed aforementioned function via remote wireless controlling system automatically, and 24 h a day uninterruptedly to ensure the comfort and privacy of the patient.

Discussions

During the COVID-19 pandemic, the emotional stress of the healthcare staff in the isolation ward is enormous. Contactless assessment of the important physiological parameters can reduce the risk of transmission of COVID-19 virus, and also boost the morale of the team members. The camera based vital sign sensors have been developed for the past 20 years. The majority of these contactless devices are infrared thermography with a Red-Green-Blue (RGB) digital camera. The applications of these sensors are monitoring of neonates in neonatal intensive care units, monitoring of heart rate during regional anesthesia, during dialysis and in the post-anesthesia care units. [9] Since the RGB camera records the facial features of the patient, there may be violations of privacy. Due to the same issue, the device can’t be installed in the toilet or shower room. On the other hand, the self-injection-locked radar uses the wideband oscillators and extracts accurate vital signs from the received Doppler-shifted signal. There is no high-resolution image captured, and the privacy issue is minimized. (Fig. 1).
Fig. 1

The thermography without high resolution image of patient can protect the privacy of the patient. The heart rate and respiratory rate are listed on the right side

The thermography without high resolution image of patient can protect the privacy of the patient. The heart rate and respiratory rate are listed on the right side In our hospital, we have setup a self-injection-locked radar on the ceiling of the ward and its bathroom to monitor patient’s vital signs. (Fig. 2) The device has been used to collect the heart rate and body temperature of the isolated patient from COVID-19. The data is consistent with the nursing handover record. The P value by Fisher’s exact test are temperature, P > 0.05 and heart rate, P > 0.05 respectively. There is no statistics difference between these two sets of data. For patients in the isolation ward, the healthcare staff has to care them under PPE. However, in the report of Wang et al., the virus nucleic acid can be tested in multiple surface areas in the patient’s room. [10] Therefore, utilizing the contactless radar technology allows the healthcare staff to check the heart rate and temperature of the patient from the nursing station (a clean zone) anytime. The nursing staffs no longer need to rush into the rooms to check the patients’ vital signs if patients fall asleep. The continuously heart rate data can help medical staffs to rule out bradycardia situation of the patient. This can decrease the infection and transmission risk for the healthcare staff.
Fig. 2

One self-injection-locked radar locates on the ceiling of the water closet to monitor patient vital sign in this private area

One self-injection-locked radar locates on the ceiling of the water closet to monitor patient vital sign in this private area Furthermore, the device can detect the actual position of isolated patients via sensing movements of the human face and body. Since cough and shortness of breath are very important symptoms of COVID-19, we also could use the self-injection-locked radar to detect the real-time movement of cough and any respiratory movement. This function can save time for the healthcare staff since there is no need to physically check on patients frequently. Another benefit is the reduced waste of PPE. The wireless feature will also provide another advantage for long period of isolation; the patient won’t be “cabled” with the EKG wires. Patients under long-term isolation normally suffer from uncomfortable mental stress. The wireless device can provide comfort and privacy for them. The device is programmed with Artificial Intelligence (AI) self-learning function. This function can detect the abnormal physical data trend, such as the pause or deceleration of respiratory rate. As aforementioned advantages and features, we are here to share the experiences and extend the usage of this device for COVID-19 patients under isolation.

Conclusions

This is the first report about the application experience of this equipment. Therefore we attempted to share the experience and try to apply this equipment in COVID-19 patients in future to offer the more reliable and safe policy. (XLSX 12 kb) (PDF 2140 kb)
  5 in total

1.  Contamination: a comparison of 2 personal protective systems.

Authors:  Jorge E Zamora; John Murdoch; Brian Simchison; Andrew G Day
Journal:  CMAJ       Date:  2006-08-01       Impact factor: 8.262

Review 2.  Wrist Pulse Rate Monitor Using Self-Injection-Locked Radar Technology.

Authors:  Fu-Kang Wang; Mu-Cyun Tang; Sheng-Chao Su; Tzyy-Sheng Horng
Journal:  Biosensors (Basel)       Date:  2016-10-26

Review 3.  A Broader Look: Camera-Based Vital Sign Estimation across the Spectrum.

Authors:  Christoph Hoog Antink; Simon Lyra; Michael Paul; Xinchi Yu; Steffen Leonhardt
Journal:  Yearb Med Inform       Date:  2019-08-16

Review 4.  Intensive care management of coronavirus disease 2019 (COVID-19): challenges and recommendations.

Authors:  Jason Phua; Li Weng; Lowell Ling; Moritoki Egi; Chae-Man Lim; Jigeeshu Vasishtha Divatia; Babu Raja Shrestha; Yaseen M Arabi; Jensen Ng; Charles D Gomersall; Masaji Nishimura; Younsuck Koh; Bin Du
Journal:  Lancet Respir Med       Date:  2020-04-06       Impact factor: 30.700

5.  Environmental virus surveillance in the isolation ward of COVID-19.

Authors:  H Wang; P Mo; G Li; P Chen; J Liu; H Wang; F Wang; Y Zhang; Q Zhao
Journal:  J Hosp Infect       Date:  2020-04-15       Impact factor: 3.926

  5 in total
  2 in total

Review 1.  An Overview of Thermal Infrared Imaging-Based Screenings during Pandemic Emergencies.

Authors:  David Perpetuini; Chiara Filippini; Daniela Cardone; Arcangelo Merla
Journal:  Int J Environ Res Public Health       Date:  2021-03-22       Impact factor: 3.390

Review 2.  Machine learning empowered COVID-19 patient monitoring using non-contact sensing: An extensive review.

Authors:  Umer Saeed; Syed Yaseen Shah; Jawad Ahmad; Muhammad Ali Imran; Qammer H Abbasi; Syed Aziz Shah
Journal:  J Pharm Anal       Date:  2022-01-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.