| Literature DB >> 32841686 |
Tianxiang Ge1, Ye Lu2, Shufa Zheng3, Lixin Zhuo4, Ling Yu5, Zuowei Ni1, Yanan Zhou1, Lingmei Ni1, Tingting Qu6, Zifeng Zhong7.
Abstract
BACKGROUND: Coronavirus disease 2019 has spread globally and been a public health emergency worldwide. It is important to reduce the risk of healthcare associated infections among the healthcare workers and patients. This study aimed to investigate the contamination of environment in isolation wards and sewage, and assess the quality of routine disinfection procedures in our hospital.Entities:
Keywords: Isolation wards; SARS-CoV-2; Sewage; Surfaces
Mesh:
Year: 2020 PMID: 32841686 PMCID: PMC7443056 DOI: 10.1016/j.ajic.2020.08.028
Source DB: PubMed Journal: Am J Infect Control ISSN: 0196-6553 Impact factor: 2.918
Fig 1Room layout in isolation wards and location of positive surface samples for SARS-CoV-2 detection.
X: location of positive surface samples for SARS-CoV-2 detection.
SARS-cov-2 detections in the surface samples collected from the isolation wards in the interval between routine disinfection procedures
| Areas | Sampling sites | Total number of samples | Positive number of samples | Cycle threshold value |
|---|---|---|---|---|
| Contaminated area | Beepers | 2 | 0 | |
| Flush button of the toilet bowl | 17 | 1 | 36.53 | |
| Hand-basin | 9 | 1 | 36.83 | |
| Bedrails | 2 | 0 | ||
| Bedside tables | 16 | 0 | ||
| Door handles | 9 | 0 | ||
| Telephones | 2 | 0 | ||
| Medical equipment | 7 | 0 | ||
| Desktops | 5 | 0 | ||
| Medical refuse transfer trolley | 6 | 0 | ||
| Nurse station | 10 | 0 | ||
| Chairs | 3 | 0 | ||
| Computer mouses | 3 | 0 | ||
| Nursing trolley | 5 | 0 | ||
| Semi-contaminated area | Computer mouses | 2 | 0 | |
| Keyboards | 2 | 0 | ||
| Clean area | Elevator hall | 2 | 0 | |
| Elevators | 3 | 0 |
SARS-cov-2 detections in the sewage samples collected from preprocessing disinfection equipment and final disinfection pool
| Sites | Total number of samples | Positive numbers of samples | Cycle threshold value |
|---|---|---|---|
| Inlets of preprocessing disinfection equipment | 14 | 6 | 35.97, 37.80, 28.78, 30.58, 29.37, 35.93 |
| Outlets of preprocessing disinfection pool | 14 | 4 | 27.72, 33.55, 34.35, 34.58 |
| Final pool of sewage disinfection | 13 | 0 |
SARS-cov-2 detections in the surface samples collected from the examination rooms after the terminal disinfection
| Sites | Total number of samples | Positive numbers of samples |
|---|---|---|
| Endoscopy room | 4 | 0 |
| Computed tomography room | 6 | 0 |
| Electroencephalogram Examination room | 5 | 0 |
| Magnetic resonance imaging room | 2 | 0 |