Literature DB >> 32837690

Using air curtains to reduce short-range infection risk in consulting ward: A numerical investigation.

Jin Ye1,2, Hua Qian1,2, Jianchao Ma1,2, Rong Zhou3,4, Xiaohong Zheng1,2,5.   

Abstract

Air curtains is promising in reducing the short-range infection risk in hospitals. To quantitatively evaluate its performance, this paper explores air curtains equipped on normal consulting desk to avoid doctor's direct exposure to the patient exhaled pollutants. A numerical investigation is conducted to evaluate the effects of supply air velocity and angle on cutting off performance. Simulation results show that the average mass fraction of exhaled pollutants decreases significantly (70%-90%) in the consulting ward, indicating satisfying performance of air curtains. Increasing supply air velocity is demonstrated to be conducive in forming full air curtains, whereas an excessively high supply air velocity may be of adverse effects by entraining exhaled flow. Besides, the supply air angle is also critical due to its coupling with supply air velocity. It is found that larger angle (0°-40°) is better where velocity is less than 3 m/s, otherwise a small angle (20°) is preferable where velocity is larger than 3 m/s. Exhaled flow could be well suppressed at the supply air angle 20° but moves over air curtains at 40°. This study can provide effective and intuitive guidance in applying air curtains in consulting wards. Electronic Supplementary Material ESM: Supplementary material is available in the online version of this article at 10.1007/s12273-020-0649-7. The ESM files include the animation of patient exhaled droplets from the droplet birth at 0 s to 5 s under the supply air angle 0°, 20°, 40°, at supply air velocity 3 m/s. © Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2020.

Entities:  

Keywords:  air curtains; consulting ward; cutting off performance; numerical investigation

Year:  2020        PMID: 32837690      PMCID: PMC7317245          DOI: 10.1007/s12273-020-0649-7

Source DB:  PubMed          Journal:  Build Simul        ISSN: 1996-3599            Impact factor:   4.008


Supplementary material, approximately 24.0 MB. Supplementary material, approximately 23.8 MB. Supplementary material, approximately 23.3 MB.
  15 in total

1.  The epidemiology of the common cold. I.

Authors:  O M LIDWELL; R E WILLIAMS
Journal:  J Hyg (Lond)       Date:  1961-09

Review 2.  Airborne transmission of disease in hospitals.

Authors:  I Eames; J W Tang; Y Li; P Wilson
Journal:  J R Soc Interface       Date:  2009-10-14       Impact factor: 4.118

3.  Direct or indirect exposure of exhaled contaminants in stratified environments using an integral model of an expiratory jet.

Authors:  Fan Liu; Chongyang Zhang; Hua Qian; Xiaohong Zheng; Peter V Nielsen
Journal:  Indoor Air       Date:  2019-05-23       Impact factor: 5.770

4.  A randomized clinical trial of three options for N95 respirators and medical masks in health workers.

Authors:  C Raina MacIntyre; Quanyi Wang; Holly Seale; Peng Yang; Weixian Shi; Zhanhai Gao; Bayzid Rahman; Yi Zhang; Xiaoli Wang; Anthony T Newall; Anita Heywood; Dominic E Dwyer
Journal:  Am J Respir Crit Care Med       Date:  2013-05-01       Impact factor: 21.405

5.  The global burden of respiratory disease.

Authors:  Thomas Ferkol; Dean Schraufnagel
Journal:  Ann Am Thorac Soc       Date:  2014-03

6.  Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong.

Authors:  Y Li; X Huang; I T S Yu; T W Wong; H Qian
Journal:  Indoor Air       Date:  2005-04       Impact factor: 5.770

7.  A schlieren optical study of the human cough with and without wearing masks for aerosol infection control.

Authors:  Julian W Tang; Thomas J Liebner; Brent A Craven; Gary S Settles
Journal:  J R Soc Interface       Date:  2009-10-08       Impact factor: 4.118

8.  How far droplets can move in indoor environments--revisiting the Wells evaporation-falling curve.

Authors:  X Xie; Y Li; A T Y Chwang; P L Ho; W H Seto
Journal:  Indoor Air       Date:  2007-06       Impact factor: 5.770

9.  A cluster randomised trial of cloth masks compared with medical masks in healthcare workers.

Authors:  C Raina MacIntyre; Holly Seale; Tham Chi Dung; Nguyen Tran Hien; Phan Thi Nga; Abrar Ahmad Chughtai; Bayzidur Rahman; Dominic E Dwyer; Quanyi Wang
Journal:  BMJ Open       Date:  2015-04-22       Impact factor: 2.692

10.  Cluster randomised controlled trial to examine medical mask use as source control for people with respiratory illness.

Authors:  Chandini Raina MacIntyre; Yi Zhang; Abrar Ahmad Chughtai; Holly Seale; Daitao Zhang; Yanhui Chu; Haiyan Zhang; Bayzidur Rahman; Quanyi Wang
Journal:  BMJ Open       Date:  2016-12-30       Impact factor: 2.692

View more
  2 in total

1.  Combined Heat, Air, Moisture and Pollutant Simulations (CHAMPS) research for building and urban energy efficiency and environmental quality analysis.

Authors:  Zhi Gao; Weihui Liang; Shanshan Shi; Jianshun Zhang
Journal:  Build Simul       Date:  2021-01-21       Impact factor: 3.751

2.  Robustness of ventilation systems in the control of walking-induced indoor fluctuations: Method development and case study.

Authors:  Jianlin Ren; Junjie He; Xiangfei Kong; Hongwan Li
Journal:  Build Simul       Date:  2022-02-18       Impact factor: 4.008

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.