An experimental framework to capture the flow dynamics of droplets expelled by a sneeze.

Prateek Bahl1, Charitha M de Silva1, Abrar Ahmad Chughtai2, C Raina MacIntyre3, Con Doolan1.   

Abstract

ABSTRACT: Respiratory activities such as sneezing generate pathogen laden droplets that can deposit in the respiratory tract of a susceptible host to initiate infection. The extent of spread of these droplets determines the safe distance between a patient and health care worker. Here, we have presented a method to visualize the droplets expelled by a sneeze using light-sheet illumination. This method of visualization provides images that clearly resolve the velocities of droplets with minimal overlapping trajectories, towards understanding their flow dynamics. Furthermore, we present the image processing techniques required to perform accurate Particle Tracking Velocimetry to understand the motion of expelled droplets. Flow fields are presented from applying this methodology over multiple sneezes which reveal that less than 1% of droplets expelled travel at velocities greater than 10 m/s and almost 80% of droplets travel at velocities less than 5 m/s. Furthermore, we observe that some droplets are generated by ligament breakup outside the mouth and some are generated within the respiratory tract. © Springer-Verlag GmbH Germany, part of Springer Nature 2020.

Entities:  

Year:  2020        PMID: 32834458      PMCID: PMC7368616          DOI: 10.1007/s00348-020-03008-3

Source DB:  PubMed          Journal:  Exp Fluids        ISSN: 0723-4864            Impact factor:   2.480


Introduction

Coughing and sneezing are often considered as aerosol generating actions. Sneezing is characterized by a sudden involuntary expulsion of respiratory and salivary fluid along with air, from the mouth and nose, due to irritation of the mucus membrane. Sneezes expel pathogen-laden droplets of respiratory and salivary fluid that can deposit in the respiratory tract of susceptible hosts in the near-vicinity, and that may initiate the infection. Although both coughing and sneezing are sudden expulsions of air and respiratory tract fluid, studies have shown that they have certain characteristics. Specifically, initial studies by Duguid (1944) and Jennison (1942) showed that peak velocity of droplets expelled during a sneeze is significantly higher than that generated during cough and the number of droplets expelled during a sneeze are also much higher than those produced during coughing. A more recent study by Scharfman et al. (2016) showed that even the mechanism of droplet formation differs between a cough and a sneeze. As a consequence of these properties, sneezing could be a major contributor to ‘droplet’ transmission as defined by World Health Organization (2014), which is believed to occur when a person is within 1 m from someone who has respiratory symptoms (e.g., coughing or sneezing). However, most prior research on infection transmission has been focused on coughing with sneezing receiving much less attention comparatively (Zhu et al. 2006; Gupta et al. 2009; Vansciver et al. 2011; Lee et al. 2019). A reason for this bias could be the frequency of coughing, which could be up to 15 times higher in certain diseases (Loudon and Brown 1967; Dick et al. 1987). Moreover, it is also harder to induce a controlled sneeze as compared to cough for experimental studies. The infection control guidelines for the prevention of respiratory transmission makes an assumption on the safe distance between patient and health care worker based on the extent of spread of droplets expelled during respiratory events such as coughing and sneezing, and 1–2 m distance is considered safe to prevent from ‘droplet’ transmission. A recent review by Bahl et al. (2020) found that the evidence for this safe distance is very sparse. Moreover, for coronavirus disease 2019 (COVID-19) pandemic the spatial separation limit for donning Personal Protective Equipment (PPE), as defined by WHO is just 1 m (World Health Organization 2020). Therefore, understanding the dynamics of respiratory events is key to guiding infection control policy and practice in the healthcare setting, including the use of PPE to provide a barrier against large droplets and aerosols (MacIntyre et al. 2014). Modelling studies by Xie et al. (2007) and Parienta et al. (2011) have shown that the properties of the expiratory fluid and the velocity of expiration, plays a major role in determining the extent of droplet spread. Hence, a precise measurement of the velocity of expelled droplets is essential to better understand the transmission of infection. A few studies have tried to study the flow dynamics of sneezes using various techniques. Nishimura et al. (2013) used volumetric illumination and a high-speed imaging system to capture sneeze flow at 300 fps. The study employed Particle Image Velocimetry to analyse the flow and found the initial velocity to be greater than 6 m/s. It was also concluded that the reach of a sneeze is almost three times that of cough however, this study was limited to a single subject. Tang et al. (2013) collected data from 6 subjects using shadow-graph imaging at a frame rate of 2000 fps and reported a maximum velocity of 4.5 m/s. Bourouiba et al. (2014) provided a theoretical model, which was developed using high-speed sneeze visualization, analogous water tank experiments and a particle-laden cloud model, to predict the extent of pathogen spread. It was concluded that the turbulent cloud expelled during a sneeze can extend the reach of pathogen laden droplets. Scharfman et al. (2016) used high-speed cameras to capture close-range droplets using diffused white backlighting and concluded that droplets predominantly form at the exit of the mouth by a sequence of fragmentation processes. It was also concluded that the viscoelasticity of expiratory fluid is a major factor in determining the size distribution of large droplets. The maximum velocity of droplets reported in this study was 14 m/s and a velocity of up to 35 m/s was reported for ligaments, which subsequently breaks to form large droplets. A recent visualization of sneeze cloud by Bourouiba (2020) showed that turbulent gas cloud with pathogen laden droplets can travel up to 8 m away from the subject. Since droplet precaution guidelines for infection control rely on the extent of droplet spread (Siegel et al. 2007), and appears to assume no difference between droplets expelled by a cough and sneeze, it is important to understand the dynamics of individual droplets. We note that most of the published literature on sneeze flow dynamics uses volume illumination for flow visualization, coupled with a single camera. However, with volume illumination, there is an overlap of droplet trajectories, and the movement of particles along the camera axis can lead to difficulty in precisely detecting the velocity of individual particles. Other works include measurements by Scharfman (2016) which used a multi-camera arrangement together with back illumination. For single camera measurements, light sheet illumination allows to precisely locate particles in a slice of the flow-field which are not masked by the presence of particles along the camera axis. Studies by Zhu et al. (2006) and Vansciver et al. (2011) used laser sheets for Particle Image Velocimetry (PIV) to understand cough flow by making a chamber with PIV setup in which volunteers cough through an opening. Since in the case of sneezing, head movement is involved, and it is much more difficult to control a sneeze, this kind of approach is not possible to visualize sneeze flow. Accordingly, in this study, we present a set of experiments employing light sheet illumination to capture individual droplets with minimal overlapping along the axis of the camera. The images captured are then processed using Particle Tracking Velocimetry techniques to obtain precise individual droplet motion. In Sect. 2, we describe the experimental methods to capture the sneeze flow using light sheet illumination and a high-speed camera. The image processing required for the study is explained in Sect. 3. Sections 4 and 5 present the analysis of the results. We note, to complete the study approval was obtained from the University of New South Wales Human Research Ethics Committee [HC180830]. All the participants were healthy and non-smokers and provided written consent before participating in the study.

Experiments

Experimental setup used to capture droplets expelled during a sneeze. a Schematic showing top view of the setup. b A picture of the experimental setup showing the vertical light sheet (xy plane) used in the present study Droplets expelled during a sneeze were captured by employing a high-speed camera and light sheet illumination. The use of light sheet illumination and high-speed motion capture was important to resolve the details of individual droplets expelled during a sneeze. To this end, a vertical (xy) plane was illuminated using a halogen light source (see Sect. 2.1 for further details). The head of the subject was positioned in front of a black backdrop and it was aligned in such a way that subject was facing the light source and the light plane was illuminating the middle of the face (Fig. 1). Once the head was positioned the subject used a tissue paper to simulate the mucus membrane of the nasal cavity to induce a sneeze, which was captured using a high-speed camera.
Fig. 1

Experimental setup used to capture droplets expelled during a sneeze. a Schematic showing top view of the setup. b A picture of the experimental setup showing the vertical light sheet (xy plane) used in the present study

Light sheet illumination

For the present study, a light sheet is employed to illuminate the flow of a sneeze in a vertical (xy) slice. Since a single camera is used for 2D measurements, illuminating a slice of flow eliminates the averaging of the particle motion in the direction perpendicular to the light sheet when compared to volume illumination. This results in clearly resolved particle trajectories that are suitable for particle tracking. We note due to safety concerns the use of a laser sheet to visualize sneeze flow is not possible, hence, the use of an alternate light source to make a light sheet is essential for this study. To this end, a halogen spotlight with a nominal beam divergence angle of was used. To form a light sheet, a 5 mm wide and 80 mm long slit made out of aluminium sheet was fixed in front of the light source and an aspheric condenser lens with a diameter of 80 mm and a focal length of 59 mm was positioned at a distance of 59 mm from the slit to collimate the diverging light beam. Thereafter, a  mm plano-concave cylindrical lens with a focal length of 38 mm was used to diverge the beam in the vertical direction. This configuration provided a horizontal divergence angle of (see Fig. 1), which was sufficient to capture the droplets and minimize the haze due to expelled aerosols. With this arrangement, we achieved a sheet thickness of 25 ± 2 mm in the field of view captured.

High-speed motion capture

The duration of a sneeze is approximately 150–200 ms (Bourouiba et al. 2014; Scharfman et al. 2016) hence it is essential to use high-speed video to resolve the droplet motion. Accordingly, a high-speed monochrome camera (nac MEMRECAM HX-7s) was used to record high-speed videos of sneezes at a resolution of pixels and a frame rate of 1500 frames-per-sec (fps). However, at the desired exposure time at 1500 fps, the intensity level from a single light source was deemed insufficient to resolve the droplets if the camera is perpendicular to the light sheet due to the mie-scattering properties of the particles (Tropea et al. 2007). To overcome this, the camera was positioned at an angle from the direction of the light sheet. We note, recording videos at an angle introduces perspective distortion, hence, the camera was positioned at an angle of as a balance between adequate light scattering and the level of perspective distortion. Another drawback of using the camera at an angle is the inclination of the focal plane with respect to the image plane, which resulted in droplets going out of focus. Hence, we employed an f-stop of f4 to ensure all particulates remain in focus.

Image processing and analysis

Stabilizing movement of head movement. Top row shows the sneeze developing in time and the red marker shows the mid-point of the tracked feature. Bottom row shows the sneeze development after fixing the mid-point of the tracked feature To perform particle tracking, the image sequences were first passed through a sequence of pre-processing steps. In the present study, this was performed in multiple steps. First, we removed the background noise through a background subtraction from all the images in the sequence. Next, the perspective distortion that was introduced through the angled view of the camera was corrected (detailed in Sect. 3.1). Finally, to isolate the motion of the expelled droplets, the motion of the subject’s head was removed by applying a 2-axis stabilization (detailed in Sect. 3.2). We note, after this process some minimal movement in the face was still present due to muscle-flexing. This was eliminated by applying a dynamic mask to all the images as part of post-processing of the data sets (detailed in Sect. 3.4).

Removing perspective distortion

To obtain a precise conversion from pixel coordinates to real coordinates, a calibration target with dots and a dot spacing of 5 mm was employed. Furthermore, this removed any perspective distortion in the images. Specifically, prior to capturing data, an image of the calibration target, placed in the focal range of the camera and aligned with the light sheet was taken. A transform was then created for this calibration image to remove the perspective distortion. This transformation was then applied to all the images in the sequence (De Silva et al. 2012).

Stabilizing head movement

Stabilizing the movement of the head is essential to isolate the motion to the expelled droplets in the image sequence and to determine the absolute velocity of expelled droplets alone. For stabilizing head movement, a feature in all the images of the image sequence was tracked (see Fig. 2). This was done using a template matching algorithm that utilised 2D normalized cross-correlation (Lewis 1995). This procedure was chosen as it is less sensitive to variations in lighting.
Fig. 2

Stabilizing movement of head movement. Top row shows the sneeze developing in time and the red marker shows the mid-point of the tracked feature. Bottom row shows the sneeze development after fixing the mid-point of the tracked feature

Once the feature tracking was completed successfully the midpoint of the tracked feature was forced to be fixed at a particular location across all the images. This was done by dynamically shifting the whole image array based on the vertical and horizontal displacement of the tracked feature. Thereafter, images were cropped based on the field of view available in the image at the final location of the head. The output of this process is shown in Fig. 2. The first image sequence (top row) shows the midpoint of the tracked feature using normalized cross-correlation (marked with a red marker). And the second image (bottom row) sequence shows the tracked feature at a fixed position to stabilize the movement of the head.

Particle tracking velocimetry

After pre-processing the images, Particle Tracking Velocimetry (PTV) was performed on the image sequence to understand the flow dynamics of expelled droplets. Lavision® Davis 8.4 was used to process the data. Specifically, due to the high seeding density in certain regions of the image, the procedure first performs a Particle Image Velocity (PIV) pass on the image sequence to obtain a velocity field estimate and then tracks individual particles using PTV algorithm (Cowen and Monismith 1997). The interrogation window used for PIV step starts with an initial interrogation window size of pixels and final size of pixels with an overlap of 75%. For the PTV step, a particle size range between 6 pixels to 40 pixels was employed. This larger range was chosen to cover the range of droplet sizes present in the image sequence of the sneeze flow. The PTV algorithm tracks each particle independently and the interrogation window size is only used for an initial displacement estimate through PIV, which is then refined in the particle tracking algorithm. The hybrid approach used for particle tracking provides high accuracy with a maximum estimation error of ±0.5 pixels (Cowen and Monismith 1997).

Dynamic masking

A dynamic mask was employed in order to remove erroneous velocity data in the near-vicinity of the subject’s face. To this end, a facial contour of the subject was detected and any velocity data outside the area of interest was discarded (Fig. 3).
Fig. 3

Example of facial contour detected to generate a mask for removing erroneous velocity vectors. Red line shows the mask applied on a single frame of the image sequence

Example of facial contour detected to generate a mask for removing erroneous velocity vectors. Red line shows the mask applied on a single frame of the image sequence To find the facial contour, every image in the sequence was first pre-processed using pixel intensity manipulation to accentuate the edge of the face. Thereafter, a 2D convolution was performed on the image using and gradient filters to obtain horizontal and vertical gradients. Once the gradients were calculated a Fuzzy Interface System (FIS) was created for edge detection with horizontal and vertical image gradients as input (MATLAB 2019). Specifically, one Gaussian membership function was defined for each input and two triangular membership functions were defined for the output. The FIS system makes the pixel white in the output image if the image gradient in both horizontal and vertical directions was zero. If there was any non-zero gradient, horizontal or vertical, at the pixel location then it meant that pixel is on the edge and the output was black. This process was performed for each row of pixels in the image to find the facial contour. Once facial contour was determined, each pixel row was analysed to get a unique edge location. This spatial information of edge location in each image was then combined in a single file which acts as a dynamic mask for that particular image sequence.

Examination of sneeze flow-fields

Variation in expelled droplets of 3 different sneezes. Snapshots shown are at 150 ms after the onset of sneeze. Here, a and c are snapshots of different sneeze sequence from same individual Small droplets expelled from the mouth at 85–87 ms and at 185–187 ms for sneeze 2 Probability distribution of velocity vectors obtained by particle tracking for the complete duration and field of view of sneeze 1, sneeze 2 and sneeze 3 Development of Sneeze. The image sequence shows multiple snapshots of sneeze 2 separated by an interval of 40 ms Velocity vectors of expelled droplets for sneeze 2 100 ms after the onset of sneeze To characterise the flow-field of the sneeze, the aforementioned methodology was applied to a set of sneezes captured. Although the sample size was limited to 2 subjects, significant differences were observed between sneezes, even from the same subject, in terms of droplet velocity and duration of the sneeze. Furthermore, the number of expelled droplets observed also varied significantly, which highlights the importance of examining a large set of sneezes towards fully characterising the behaviour of sneeze flow. To visualize these differences, 3 independent sneezes are presented in Fig. 4. Here, sneeze 1, in Fig. 4a and sneeze 3, in Fig. 4c are from the same subject yet still exhibit differences in terms of droplets expelled and the duration of a sneeze. Specifically, more droplets can be observed in sneeze 1 when compared to sneeze 3. Another phenomenon we observed in sneeze 1 is the presence of ligaments close to mouth which appears to breaks into individual droplets with time. This could be due to various hydrodynamic instabilities, as highlighted by Scharfman et al. (2016), where they observed similar phenomena through flow visualisation experiments. Sneeze 2, in Fig. 4b is from a different subject and it can be observed that there is presence of ligaments near the mouth exit, however, most detected small droplets appear to be expelled directly out of the mouth (Fig. 5). Which implies that although large droplets are formed at the exit of the mouth by ligament breakup, small droplets are formed within the respiratory tract. Another important observation is that although ligaments are present in both sneeze 1 and sneeze 2 in the latter we observe a rapid conversion of ligaments to droplets. This could be due to variation in airflow and viscoelasticity of salivary fluid of different sneezes (Fig. 4).
Fig. 4

Variation in expelled droplets of 3 different sneezes. Snapshots shown are at 150 ms after the onset of sneeze. Here, a and c are snapshots of different sneeze sequence from same individual

Fig. 5

Small droplets expelled from the mouth at 85–87 ms and at 185–187 ms for sneeze 2

Figure 6 shows the distribution of velocity vectors for all three sneezes and it can be observed that sneeze 1 and sneeze 2 exhibit more vectors in the range of 5–10 m/s as compared to sneeze 3. In sneeze 3, most of the vectors are in the range of 0–5 m/s. These differences in velocity vector distributions, specifically in sneeze 3 could be due to the variation in the droplets captured in the slice of flow, as the droplets visible in sneeze 3 are much less compared to other 2 sneezes, which can be observed in Fig. 4. We note that ligaments are treated as single large particles in the particle tracking approach used and the velocity vectors associated with ligaments are also included in the distribution shown in Fig. 6.
Fig. 6

Probability distribution of velocity vectors obtained by particle tracking for the complete duration and field of view of sneeze 1, sneeze 2 and sneeze 3

The set of images in Fig. 7 shows the development of sneeze 2 in time. The onset of the sneeze is determined by visually detecting the start of airflow from the mouth or nose of the subject. In this case, the sneeze lasted for approximately 190 ms and the maximum observed velocity of particles expelled is approximately 14 m/s.
Fig. 7

Development of Sneeze. The image sequence shows multiple snapshots of sneeze 2 separated by an interval of 40 ms

We note that although the methodology employed resolved droplet dynamics only over a vertical (xy) slice of the sneeze flow it still highlights the variability among different sneezes. Specifically, a typical sneeze lasted for approximately 180–200 ms and the maximum droplet velocity observed ranged from 12–15 m/s but, the number of droplets expelled varied a lot as can be observed in Fig. 4. This can significantly influence the extent of spread of expelled droplets which is the basis of droplet infection control guidelines (World Health Organization 2020). It should be noted that the variation in expelled droplets could be partially due to the fact that only a slice of flow was illuminated, or the mouth of some subjects could be drier and produced fewer droplets. Nevertheless, it is also possible that the number of droplets expelled varies substantially between different sneezes, and hence, future works with larger sample size are required to explore this further. Moreover, the actual droplet count is also likely to depend on the level of illumination available which dictates the smallest droplets that can be detected. Mean velocity, standard deviation, and sneeze duration among 3 different sneezes shown in Fig. 4 Probability distribution of particle velocity vectors of sneeze 2 at three different locations from the mouth exit Table 1 shows the mean velocity, standard deviation, and sneeze duration among the three different sneezes. In addition to this, the 99th percentile droplet velocity for Sneeze 1, Sneeze 2, and Sneeze 3 are 9.69 m/s, 9.26 m/s, and 8.66 m/s, respectively. And 80th percentile droplet velocity for Sneeze 1, Sneeze 2, and Sneeze 3 are 5.36 m/s, 4.78 m/s, and 4.77 m/s, respectively. This implies that less than 1% of the droplets expelled travel at velocities greater than 10 m/s and almost 80% of the droplets travel at velocities slower than 5 m/s. The maximum velocities of droplets observed are in the range of 12–15 m/s, which is higher than the values reported by Nishimura et al. (2013) and Tang et al. (2013). These values are similar to the maximum droplet velocity reported by Scharfman et al. (2016) but, significantly less than the ligament velocity reported in that study. These values are also lower than those assumed by Xie et al. (2007) for modelling. The maximum estimation error in particle tracking algorithm is ±0.5 pixels hence, the error in the velocity estimates would be less than ±0.1 m/s. To statistically determine the best conditions for modelling velocity of droplets expelled during a sneeze, further work over a significantly larger sample size would be necessary and will be the subject of a future study.
Table 1

Mean velocity, standard deviation, and sneeze duration among 3 different sneezes shown in Fig. 4

Sneeze no.Mean velocity (m/s)Std. deviation (m/s)Duration (s)
013.81.90.196
023.32.00.190
033.01.80.184
Figure 8 shows the velocity vectors of droplets expelled in sneeze 2. To quantify the expelled droplet flow-field, Fig. 9 shows the probability distribution of droplet velocity vectors at three different distances from the mouth. These locations were chosen to span our field of view and to get a quantitative measure of the velocity distribution as a function of stream-wise distance. Our field of view for the sneeze was restricted to 30 cm due to the head movement of the subject so, 3 points were chosen—one close to mouth, one in the middle of the field of view, and one close to the end. The results reveal an initial increase in velocity vectors of magnitude greater than 5 m/s at a distance of 10–15 cm from mouth exit. Since small droplets expelled generally move with the airflow (Hinds 1999), this increase in high velocity vectors implies that either there is an increase in number of large droplets or the droplets are accelerating initially. The increase in number of droplets could be explained by the fact that a series of ligament breakup happens at the mouth exit as shown by Scharfman et al. (2016).
Fig. 8

Velocity vectors of expelled droplets for sneeze 2 100 ms after the onset of sneeze

Fig. 9

Probability distribution of particle velocity vectors of sneeze 2 at three different locations from the mouth exit

Summary and outlook

This study presents an experimental framework to visualize individual distinct droplets expelled during a sneeze which utilises particle tracking velocimetry to understand the droplet motion more precisely. The visualization technique used allows to locate particles without overlap along the camera axis and leads to precise droplet velocity measurements. Our findings highlight the variation in the velocity distribution of droplets expelled in different sneezes and points toward the possibility of a large variation in the number of droplets expelled, both among the sneezes by same individual and between different individuals. We observed the formation of droplets by breakup of ligaments at the mouth exit and expulsion of small particles directly from the respiratory tract. These findings highlight the shortcoming of studies trying to characterize sneeze flow and size distribution of expelled droplets with small sample size. There is also a possibility of differences in the viscoelasticity of expiratory fluid of different individuals as we observed rapid ligament to droplet conversion in sneeze 2. This is an important factor in determining the size distribution of large droplets and the extent of their spread hence, future studies on this aspect with large datasets are also important to better understand the size distribution of the droplets generated. This study only used healthy subjects, and the composition of expiratory fluid may be different in individuals with respiratory infections. It will be valuable to study the difference in viscoelasticity and subsequently the droplet count between healthy and infected subjects, and how infection may affect a sneeze. A limitation of visualising a planar slice of the sneeze flow is the exclusion of a significant number of droplets from the captured image sequence. As we are visualising a planar slice to accurately determine the flow speeds associated with expelled droplets, the droplets out of the plane are excluded from the analysis. In summary, this study presents a methodology to accurately quantify the velocity field associated with droplet motion in sneezes. The technique is thereafter validated through applying it to multiple sneezes captured to highlight its potential, and in doing so we also observed the marked differences between the sneezes captured. These variations observed in sneeze characteristics highlights that it is essential to have a large sample size to fully characterise the droplet trajectories towards estimating and modelling the extent of spread for a general sneeze, which will be addressed in a future work that will employ a substantially larger sample size.
  12 in total

1.  The size and the duration of air-carriage of respiratory droplets and droplet-nuclei.

Authors:  J P Duguid
Journal:  J Hyg (Lond)       Date:  1946-09

2.  2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care Settings.

Authors:  Jane D Siegel; Emily Rhinehart; Marguerite Jackson; Linda Chiarello
Journal:  Am J Infect Control       Date:  2007-12       Impact factor: 2.918

3.  Aerosol transmission of rhinovirus colds.

Authors:  E C Dick; L C Jennings; K A Mink; C D Wartgow; S L Inhorn
Journal:  J Infect Dis       Date:  1987-09       Impact factor: 5.226

4.  Cough frequency in patients with respiratory disease.

Authors:  R G Loudon; L C Brown
Journal:  Am Rev Respir Dis       Date:  1967-12

5.  Flow dynamics and characterization of a cough.

Authors:  J K Gupta; C-H Lin; Q Chen
Journal:  Indoor Air       Date:  2009-07-31       Impact factor: 5.770

6.  How far droplets can move in indoor environments--revisiting the Wells evaporation-falling curve.

Authors:  X Xie; Y Li; A T Y Chwang; P L Ho; W H Seto
Journal:  Indoor Air       Date:  2007-06       Impact factor: 5.770

7.  A new methodology for studying dynamics of aerosol particles in sneeze and cough using a digital high-vision, high-speed video system and vector analyses.

Authors:  Hidekazu Nishimura; Soichiro Sakata; Akikazu Kaga
Journal:  PLoS One       Date:  2013-11-27       Impact factor: 3.240

8.  Airflow dynamics of human jets: sneezing and breathing - potential sources of infectious aerosols.

Authors:  Julian W Tang; Andre D Nicolle; Christian A Klettner; Jovan Pantelic; Liangde Wang; Amin Bin Suhaimi; Ashlynn Y L Tan; Garrett W X Ong; Ruikun Su; Chandra Sekhar; David D W Cheong; Kwok Wai Tham
Journal:  PLoS One       Date:  2013-04-01       Impact factor: 3.240

9.  Visualization of sneeze ejecta: steps of fluid fragmentation leading to respiratory droplets.

Authors:  B E Scharfman; A H Techet; J W M Bush; L Bourouiba
Journal:  Exp Fluids       Date:  2016-01-20       Impact factor: 2.480

Review 10.  Airborne or Droplet Precautions for Health Workers Treating Coronavirus Disease 2019?

Authors:  Prateek Bahl; Con Doolan; Charitha de Silva; Abrar Ahmad Chughtai; Lydia Bourouiba; C Raina MacIntyre
Journal:  J Infect Dis       Date:  2022-05-04       Impact factor: 7.759

View more
  15 in total

1.  Computational investigation of prolonged airborne dispersion of novel coronavirus-laden droplets.

Authors:  Masashi Yamakawa; Atsuhide Kitagawa; Kiyota Ogura; Yongmann M Chung; Minsuok Kim
Journal:  J Aerosol Sci       Date:  2021-02-08       Impact factor: 3.433

2.  Can face masks offer protection from airborne sneeze and cough droplets in close-up, face-to-face human interactions?-A quantitative study.

Authors:  Javed Akhtar; Abner Luna Garcia; Leonardo Saenz; Sarada Kuravi; Fangjun Shu; Krishna Kota
Journal:  Phys Fluids (1994)       Date:  2020-12-01       Impact factor: 3.521

3.  Detecting COVID-19 from Breath: A Game Changer for a Big Challenge.

Authors:  Giorgia Giovannini; Hossam Haick; Denis Garoli
Journal:  ACS Sens       Date:  2021-04-07       Impact factor: 7.711

4.  Transport and evaporation of virus-containing droplets exhaled by men and women in typical cough events.

Authors:  Stefano Olivieri; Mattia Cavaiola; Andrea Mazzino; Marco E Rosti
Journal:  Meccanica       Date:  2022-01-12       Impact factor: 2.538

5.  Particle-Size-Dependent Filtration Efficiency, Breathability, and Flow Resistance of Face Coverings and Common Household Fabrics Used for Face Masks During the COVID-19 Pandemic.

Authors:  Olukayode James Ayodeji; Terrell A Hilliard; Seshadri Ramkumar
Journal:  Int J Environ Res       Date:  2022-01-10       Impact factor: 3.229

6.  The feasibility of masks and face shields designed by 3D printing makers; some considerations of their use against the COVID-19.

Authors:  R S Monzamodeth; N I Román-Roldán; B Hernández-Morales; I Puente; O Flores; F Castillo; B Campillo
Journal:  Mater Today Proc       Date:  2021-12-31

Review 7.  A review on the transmission of COVID-19 based on cough/sneeze/breath flows.

Authors:  Mouhammad El Hassan; Hassan Assoum; Nikolay Bukharin; Huda Al Otaibi; Md Mofijur; Anas Sakout
Journal:  Eur Phys J Plus       Date:  2021-12-10       Impact factor: 3.911

8.  Breakup morphology of expelled respiratory liquid: From the perspective of hydrodynamic instabilities.

Authors:  M Vadivukkarasan; K Dhivyaraja; Mahesh V Panchagnula
Journal:  Phys Fluids (1994)       Date:  2020-09-01       Impact factor: 3.521

9.  Investigation of theoretical scaling laws using large eddy simulations for airborne spreading of viral contagion from sneezing and coughing.

Authors:  K Liu; M Allahyari; J Salinas; N Zgheib; S Balachandar
Journal:  Phys Fluids (1994)       Date:  2021-06-29       Impact factor: 3.521

10.  Effects of the filter microstructure and ambient air condition on the aerodynamic dispersion of sneezing droplets: A multiscale and multiphysics simulation study.

Authors:  Kyeongeun Lee; Jungtaek Oh; Dongwhan Kim; Jinbok Yoo; Gun Jin Yun; Jooyoun Kim
Journal:  Phys Fluids (1994)       Date:  2021-06-24       Impact factor: 3.521

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.