Literature DB >> 32822709

Behavior of the muscle quality index and isometric strength in elderly women.

Daniel Jerez-Mayorga1, Pedro Delgado-Floody2, Leonardo Intelangelo3, Christian Campos-Jara4, Leonidas Arias-Poblete4, Juan García-Verazaluce5, Amador Garcia-Ramos6, Luis Javier Chirosa7.   

Abstract

This study aimed (I) to compare the muscle quality index (MQI) and the isometric hip strength between younger and older women, and (II) to determine the relationship of the MQI with the sit-to-stand test (STS) and isometric hip strength in younger and older women. Twenty-eight elderly women (age= 66.2 ± 5.6 years) and twenty younger women (21.2 ± 2.2 years) participated in the study. The following dependent variables were measured: MQI, STS, body composition, and the peak isometric strength of the hip (PF) which was also normalized using three different methods (PF/Body Mass, PF/Fat-Free Mass, and PF/Body Mass0,335). Older women presented a lower PF in hip flexion, extension and external rotation regardless of the method of normalization (p < 0.001), but the PF of hip abductors and internal rotators was higher for older women (p < 0.05). No significant differences were found in the MQI between older and younger women (p = 0.443). The MQI was negatively correlated with the time in the STS in older women (r = -0.706, p < 0.001) and younger women (r = -0.729, p < 0.001), while the correlations of MQI with isometric hip strength were weaker in older women (r range: -0.082 - 0.556) and younger women (r range: -0.020 - 0.309). MQI is a clinical and practical tool to assess the muscular power of the lower extremities.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Functional electromechanical dynamometer; Muscle quality; Resistance exercise; Sit-to-stand test

Mesh:

Year:  2020        PMID: 32822709     DOI: 10.1016/j.physbeh.2020.113145

Source DB:  PubMed          Journal:  Physiol Behav        ISSN: 0031-9384


  4 in total

1.  Muscle Quality of Knee Extensors Based on Several Types of Force in Multiple Sclerosis Patients with Varying Degrees of Disability.

Authors:  Kora Portilla-Cueto; Carlos Medina-Pérez; Ena Monserrat Romero-Pérez; Gabriel Núñez-Othón; Mario A Horta-Gim; José Antonio de Paz
Journal:  Medicina (Kaunas)       Date:  2022-02-19       Impact factor: 2.430

2.  30 s sit-to-stand power is positively associated with chest muscle thickness in COVID-19 survivors.

Authors:  Rodrigo Núñez-Cortés; Carlos Cruz-Montecinos; Francisco Martinez-Arnau; Rodrigo Torres-Castro; Esteban Zamora-Risco; Sofía Pérez-Alenda; Lars L Andersen; Joaquín Calatayud; Estanislao Arana
Journal:  Chron Respir Dis       Date:  2022 Jan-Dec       Impact factor: 3.115

3.  Test-Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults.

Authors:  Daniel Jerez-Mayorga; Álvaro Huerta-Ojeda; Luis Javier Chirosa-Ríos; Francisco Guede-Rojas; Iris Paola Guzmán-Guzmán; Leonardo Intelangelo; Claudia Miranda-Fuentes; Pedro Delgado-Floody
Journal:  Int J Environ Res Public Health       Date:  2021-06-25       Impact factor: 3.390

4.  Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players.

Authors:  Antonio Jesús Sánchez-Sánchez; Daniel Jerez-Mayorga; Luis Javier Chirosa-Ríos; Ignacio Jesús Chirosa-Ríos; Agustín José García-Vega
Journal:  PeerJ       Date:  2021-07-14       Impact factor: 2.984

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.