Antonio Jesús Sánchez-Sánchez1, Daniel Jerez-Mayorga2, Luis Javier Chirosa-Ríos1, Ignacio Jesús Chirosa-Ríos1, Agustín José García-Vega1.
Abstract
BACKGROUND: The use of a functional electromechanical dynamometer (FEMD) has been proposed as a valid and effective tool to evaluate specific movement patterns. The aim of this study was to determine the reliability of FEMD on swing eccentric hamstring exercise (SEHE) measures in soccer players.Entities:
Keywords: Dynamometer; Eccentric; Hamstring; Isokinetic; Lower extremity; Soccer players
Year: 2021 PMID: 34316399 PMCID: PMC8286058 DOI: 10.7717/peerj.11743
Source DB: PubMed Journal: PeerJ ISSN: 2167-8359 Impact factor: 2.984
Figure 1Swing eccentric hamstring exercise protocol.
(A) Start position, (B) initial contact stance phase, (C) take off stance phase, (D) initial swing phase, (E) middle-swing phase, (F) terminal-swing phase and start position.
Test-retest reliability of the FEMD using different isokinetic velocities during SEHE.
| Condition | Session 1 | Session 2 | F(1,18) | ES (95% CI) | CV (95% CI) | SEM (95% CI) | ICC (95% CI) | ||
|---|---|---|---|---|---|---|---|---|---|
| Average load | 20 (cm/s) | 336.2 ± 42.3 | 350.8 ± 47.5 | 0.032 | 5.35 | 0.32 [−0.58 to 1.23] | 5.67 [4.28–8.38] | 19.47 [14.71–28.80] | 0.83 [0.61–0.93] |
| 40 (cm/s) | 388.2 ± 43.7 | 402.2 ± 39.3 | 0.001 | 15.05 | 0.34 [−0.57 to 1.24] | 2.80 [2.12–4.14] | 11.07 [8.31–6.37] | 0.94 [0.84–0.99] | |
| 60 (cm/s) | 412.9 ± 58.0 | 429.3 ± 61.5 | 0.067 | 3.77 | 0.27 [−0.63 to 1.18] | 6.17 [4.66–9.13] | 25.99 [19.64–38.44] | 0.83 [0.61–0.93] | |
| Maximum load | 20 (cm/s) | 490.2 ± 75.6 | 510.5 ± 69.3 | 0.015 | 7.19 | 0.28 [−0.62 to 1.18] | 4.66 [3.52–6.89] | 23.32 [17.62–34.50] | 0.91 [0.78–0.96] |
| 40 (cm/s) | 544.3 ± 87.9 | 569.8 ± 78.1 | 0.022 | 6.17 | 0.31 [−0.60 to 1.21] | 5.68 [4.29–8.39] | 31.62 [23.90–46.77] | 0.87 [0.69–0.95] | |
| 60 (cm/s) | 597.6 ± 101.3 | 624.7 ± 92.1 | 0.030 | 5.48 | 0.28 [−0.62 to 1.18] | 5.85 [4.42–8.65] | 35.76 [27.02–52.90] | 0.88 [0.71–0.95] |
Notes:
Values given as mean ± standard deviation.
P < 0.005
p, p-value; F, F-value; ES, Cohen’s d effect size; CV, coefficient of variation; SEM, standard error of measurement; ICC, intra-class correlation coefficient; 95% CI, 95% confidence interval; N, newton.