Wen-Nan Huang1, Mao-Song Zhuang1, Tsun-Jen Cheng1, Shih-Huai Hsiao1,2,3.
Abstract
Reducing nosocomial transmission within health care facilities is important, but the number of negative-pressure airborne infection isolation rooms for SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) is limited. It is a daunting challenge to cope with a surge of suspected infectious patients in hospitals. We installed air exhaust fans on the windows to change the pressure direction within the wards rapidly. The best location for the fans was 90 cm from the floor and 90 cm from the edge of bed whether the indoor air conditioners were on or off. The noise level should be <60 dB(A) as per government regulations. General wards can be transformed into makeshift negative-pressure rooms easily and effectively within 24 hours, which is really the simple, fast, and effective way for the transformation being applied.Entities:
Keywords: COVID-19; airborne infection isolation rooms; health care–associated infections; negative pressure; nosocomial transmission
Mesh:
Year: 2020 PMID: 32795092 PMCID: PMC7521007 DOI: 10.1177/1010539520947874
Source DB: PubMed Journal: Asia Pac J Public Health ISSN: 1010-5395 Impact factor: 1.399
Testing Results in Makeshift Quarantine Observation Wards After Installation of Exhaust Fans.
| Ward | Total indoor volume (m2) | Technical specifications of exhaust fans | Installation location | Indoor AC | Airflow direction in corridor to ward[ | Airflow condition at bedside | Level of noise (dBA) | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Height above ground (cm) | Minimum distance to bed edge (cm) | On/off | Air volume (CMM) | To fans | From bedside to fans | Background | Patients lying on the bed[ | ||||
| 6C | 47.2 | Model LH-148/3 blades/dimension: diameter 30 cm/air volume unknown/level of noise: unknown/56 W | 180 | 120 | On | 17 | +++ | — | — | 51.2 | 55.8 |
| 6C | 47.2 | 180 | 120 | Off | 0 | +++ | — | — | 51.2 | 54.6 | |
| 6C | 47.2 | 90 | 120 | On | 17 | +++ | + | — | 51.2 | 56.4 | |
| 6C | 47.2 | 90 | 120 | Off | 0 | +++ | + | — | 51.2 | 55.3 | |
| 6C | 47.2 | 90 | 100 | On | 17 | +++ | + | + | 51.2 | 56.4 | |
| 6C | 47.2 | 90 | 90 | On | 17 | +++ | + | + | 51.2 | 58.2* | |
| 6C | 47.2 | 90 | 70 | On | 17 | +++ | ++ | + | 51.2 | 61.5 | |
| 6C | 47.2 | 90 | 60 | On | 17 | +++ | +++ | ++ | 51.2 | 63.2 | |
| 6C | 55.4 | Model JFB-14H/3 blades/dimension: diameter 55 cm/air volume: 55 CMM/level of noise:52dB(A)/35 W | 180 | 120 | On | 17 | +++ | — | — | 53.5 | 56.3 |
| 6C | 55.4 | 180 | 120 | Off | 0 | +++ | — | — | 53.5 | 56.4 | |
| 6C | 55.4 | 90 | 120 | On | 17 | +++ | — | + | 53.5 | 57 | |
| 6C | 55.4 | 90 | 120 | Off | 0 | +++ | — | + | 53.5 | 56.2 | |
| 6C | 55.4 | 90 | 110 | On | 17 | +++ | + | + | 53.5 | 55.1 | |
| 6C | 55.4 | 90 | 100 | On | 17 | +++ | ++ | ++ | 53.5 | 55.4 | |
| 6C | 55.4 | 90 | 90 | On | 17 | +++ | +++ | ++ | 53.5 | 54.7 | |
+++, visible smooth flow; ++, visible little smooth flow; +, visible little smooth flow but slow.
dB(A)-Leq24 is measured by a decibel meter, which is certificated by the Office of Occupational Safety and Health Administration, Taiwan.