Noah J Adams1, David L Johnson, Robert A Lynch. 1. Department of Occupational and Environmental Health, University of Oklahoma College of Public Health, Oklahoma City, OK 73126, USA.
Abstract
BACKGROUND: Airborne infectious isolation rooms (AIIRs) are maintained at a negative pressure relative to surrounding areas to prevent migration of potentially infectious droplet nuclei. Current US design standards require a pressure differential of only 2.5 Pascals (Pa), compared with 15 Pa in some other countries. The purpose of this work was to compare containment efficiency in a properly designed anteroom-equipped hospital AIIR at differential pressures ranging from 2.5 to 20 Pa under conditions of no provider traffic and simulated high provider traffic. METHODS: Fluorescent microspheres were released into the AIIR to simulate infectious droplet nuclei. Airborne concentrations were measured inside the AIIR, in the anteroom, and at the corridor-anteroom door both with and without care provider movement through the AIIR under differential pressure conditions of 2.5, 11, and 20 Pa. Particles were collected by air sampling onto filters, with enumeration via fluorescent microscopy. RESULTS: Reduced containment effectiveness during provider traffic was observed, consistent with previous studies. Containment increased with increasingly negative pressure differential and decreased with increasing provider traffic. CONCLUSIONS: Provider traffic adversely affected containment. Containment improved with an increasing pressure differential. The anteroom plays an important role in limiting net particle escape, especially during provider movement through the space.
BACKGROUND: Airborne infectious isolation rooms (AIIRs) are maintained at a negative pressure relative to surrounding areas to prevent migration of potentially infectious droplet nuclei. Current US design standards require a pressure differential of only 2.5 Pascals (Pa), compared with 15 Pa in some other countries. The purpose of this work was to compare containment efficiency in a properly designed anteroom-equipped hospital AIIR at differential pressures ranging from 2.5 to 20 Pa under conditions of no provider traffic and simulated high provider traffic. METHODS: Fluorescent microspheres were released into the AIIR to simulate infectious droplet nuclei. Airborne concentrations were measured inside the AIIR, in the anteroom, and at the corridor-anteroom door both with and without care provider movement through the AIIR under differential pressure conditions of 2.5, 11, and 20 Pa. Particles were collected by air sampling onto filters, with enumeration via fluorescent microscopy. RESULTS: Reduced containment effectiveness during provider traffic was observed, consistent with previous studies. Containment increased with increasingly negative pressure differential and decreased with increasing provider traffic. CONCLUSIONS: Provider traffic adversely affected containment. Containment improved with an increasing pressure differential. The anteroom plays an important role in limiting net particle escape, especially during provider movement through the space.
Authors: Julian W Tang; Andre Nicolle; Jovan Pantelic; Christian A Klettner; Ruikun Su; Petri Kalliomaki; Pekka Saarinen; Hannu Koskela; Kari Reijula; Panu Mustakallio; David K W Cheong; Chandra Sekhar; Kwok Wai Tham Journal: PLoS One Date: 2013-06-24 Impact factor: 3.240
Authors: Elham Andalib; Masoumeh Faghani; Seyyed Mahdi Zia Ziabari; Mohammad Shenagari; Hamid Salehiniya; Mohammad Hossein Keivanlou; Zahra Rafat Journal: Front Public Health Date: 2022-04-26
Authors: Caroline Lopes Ciofi-Silva; Lisbeth Lima Hansen; Alda Graciele Claudio Dos Santos Almeida; Julia Yaeko Kawagoe; Maria Clara Padoveze; Kazuko Uchikawa Graziano Journal: Rev Lat Am Enfermagem Date: 2016-09-01
Authors: Shelly L Miller; Nicholas Clements; Steven A Elliott; Shobha S Subhash; Aaron Eagan; Lewis J Radonovich Journal: Am J Infect Control Date: 2017-03-20 Impact factor: 2.918
Authors: Shobha S Subhash; Gio Baracco; Kevin P Fennelly; Michael Hodgson; Lewis J Radonovich Journal: Am J Infect Control Date: 2012-10-02 Impact factor: 2.918
Authors: Francis J Offermann; Aaron Eagan; Aidan C Offermann; Shobha S Subhash; Shelly L Miller; Lewis J Radonovich Journal: Build Environ Date: 2016-06-25 Impact factor: 6.456