Literature DB >> 3276645

Accurate analysis of blood vessel sizes and stenotic lesions using stereoscopic DSA system.

L E Fencil1, K Doi, K R Hoffman.   

Abstract

We have developed a technique to determine accurately the magnification factor and three-dimensional orientation of a vessel segment from a stereoscopic pair of digital subtraction angiograms (DSA). Our DSA system includes a stereoscopic x-ray tube with a 25-mm focal spot shift. The magnification and orientation of a selected vessel segment are determined from the distance and direction of the focal spot shift and the stereoscopic discrepancy in image positions for that segment. Our results indicate that the accuracies of determining the magnification and orientation are less than 1% and approximately 5 degrees, respectively. After the magnification and orientation are determined accurately, an iterative deconvolution technique for the measurement of vessel image size is applied to the selected vessel segment. This iterative deconvolution technique provides the best estimate of vessel image size by taking into account the unsharpness of the digital system. With this technique, the vessel image size can be determined to an accuracy of approximately 1.0 mm, which corresponds to one third the pixel size of our DSA system. Information derived from stereoscopic analysis and iterative deconvolution thus allows accurate calculation of actual vascular dimensions from DSA images.

Entities:  

Mesh:

Year:  1988        PMID: 3276645     DOI: 10.1097/00004424-198801000-00008

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

Review 1.  Potential usefulness of digital imaging in clinical diagnostic radiology: computer-aided diagnosis.

Authors:  K Doi; M L Giger; R M Nishikawa; K R Hoffmann; H MacMahon; R A Schmidt
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

2.  In-vivo validation of videodensitometric coronary cross-sectional area measurement using dual-energy digital subtraction angiography.

Authors:  S Molloi; A Ersahin; J Hicks; J Wallis
Journal:  Int J Card Imaging       Date:  1995-12

3.  Assessment of vasoreactivity using videodensitometry coronary angiography.

Authors:  Sabee Molloi; Gholam R Berenji; Trien T Dang; Ghassan Kassab
Journal:  Int J Cardiovasc Imaging       Date:  2003-08       Impact factor: 2.357

4.  A quantitative evaluation of the three dimensional reconstruction of patients' coronary arteries.

Authors:  J L Klein; J G Hoff; J W Peifer; R Folks; C D Cooke; S B King; E V Garcia
Journal:  Int J Card Imaging       Date:  1998-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.