Literature DB >> 32763967

Value of FEops HEARTguide patient-specific computational simulations in the planning of left atrial appendage closure with the Amplatzer Amulet closure device: rationale and design of the PREDICT-LAA study.

Philippe Garot1, Xavier Iriart2, Adel Aminian3, Joelle Kefer4, Xavier Freixa5, Ignacio Cruz-Gonzalez6, Sergio Berti7, Liesbeth Rosseel8, Reda Ibrahim9, Kasper Korsholm10, Jacob Odenstedt11, Jens-Erik Nielsen-Kudsk10, Jaqueline Saw12, Lars Sondergaard13, Ole De Backer14.   

Abstract

BACKGROUND: Optimal preprocedural planning is essential to ensure successful device closure of the left atrial appendage (LAA).
DESIGN: The PREDICT-LAA study is a prospective, international, multicentre, randomised controlled trial (ClinicalTrials.gov NCT04180605). Two hundred patients eligible for LAA closure with an Amplatzer Amulet device (Abbott, USA) will be enrolled in the study. Patients will be allocated to a computational simulation arm (experimental) or standard treatment arm (control) using a 1:1 randomisation. For patients randomised to the computational simulation arm, preprocedural planning will be based on the analysis of cardiac computed tomography (CCT)-based patient-specific computational simulations (FEops HEARTguide, Ghent, Belgium) in order to predict optimal device size and position. For patients in the control arm, preprocedural planning will be based on local practice including CCT analysis. The LAA closure procedure and postprocedural antithrombotic therapy will follow local practice in both arms. The primary endpoint of the study is incomplete LAA closure and device-related thrombus as assessed at 3 months postprocedural CCT. Secondary endpoints encompass procedural efficiency (number of devices used, number of repositioning, procedural time, radiation exposure, contrast dye), procedure-related complications within 7 days postprocedure and a composite of all-cause death and thromboembolic events at 12 months.
CONCLUSION: The objective of the PREDICT-LAA study is to test the hypothesis that a preprocedural planning for LAA closure with the Amplatzer Amulet device based on patient-specific computational simulations can result in a more efficient procedure, optimised procedural outcomes and better clinical outcomes as compared with a standard preprocedural planning. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Registry (NCT04180605). © Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  CT scanning; atrial fibrillation; device closure; stroke

Mesh:

Year:  2020        PMID: 32763967      PMCID: PMC7412609          DOI: 10.1136/openhrt-2020-001326

Source DB:  PubMed          Journal:  Open Heart        ISSN: 2053-3624


Background

Percutaneous left atrial appendage (LAA) closure is being increasingly used as a treatment strategy to prevent stroke in patients with non-valvular atrial fibrillation (NVAF) and contraindication(s) to oral anticoagulant therapy. In order to obtain a successful LAA closure, correct LAA closure device size selection as well as optimal implantation should be pursued.1–5 Various cardiac imaging techniques are currently used to assess the anatomy and size of the LAA, ranging from two-dimensional transoesophageal echocardiographic (TEE) to cardiac computed tomography (CCT), which allows three-dimensional (3D) evaluation of the LAA and its surrounding structures. Although more detailed preprocedural LAA imaging by CCT helps to better understand and size the patient’s LAA anatomy,3 predicting the actual ‘landing zone’ of the LAA closure device still remains difficult. The use of printed 3D-LAA models has been reported as a method to improve the preprocedural planning4 5; however, this approach is not feasible in all cases due to the logistics required with 3D printing. The use of CCT-based patient-specific computational models to virtually deploy the closure device into the reconstructed patient-specific LAA anatomy is a more versatile alternative to bench testing in 3D printed models and provides additional information to cardiac imaging techniques only. The patient-specific computational simulation aims to reproduce the mechanical interaction between device and the patient’s anatomy and provides a deeper insight into the behaviour of the LAA closure device before the procedure. The FEops HEARTguide simulation technology (FEops NV, Ghent, Belgium) has been validated for LAA closure6 as well as for transcatheter aortic valve replacement procedures.7 8 The PREDICT-LAA clinical study investigates the hypothesis that a better preprocedural planning can be achieved by consulting FEops HEARTguide, simulating different LAA closure device sizes and positions in a patient-specific LAA anatomy and thereby providing the implanter an overview of possible optimal and suboptimal scenarios. This better preprocedural planning may result in higher rates of complete LAA closure with lower rates of DRT as assessed on postprocedural CCT imaging.

Methods

Study objectives

The purpose of this trial is to study the possible added value of FEops HEARTguide patient-specific computational simulations in the preprocedural planning of percutaneous LAA closure with the Amplatzer Amulet device, with focus on procedural safety and efficiency as well as on clinical outcomes.

Study population and patient selection

Two hundred patients with NVAF and eligible for LAA closure with an Amplatzer Amulet LAA closure device will be enrolled at up to 12 European and Canadian sites. Only patients referred to and approved for percutaneous LAA closure—according to local practice and legislation—can be considered for enrolment in the trial. All patients should be 18 years or older and should sign a written informed consent. Key exclusion criteria are a reduced renal function (with glomerular filtration rate <30 mL/min/1.73 m3), iodine contrast allergy or any other condition that prohibits CCT imaging, and suboptimal quality of the preprocedural CCT scan.

Randomisation and treatment protocol

Consenting subjects will be randomised in a 1:1 ratio to a standard treatment arm or computational simulation arm. Randomisation will be performed through a secure web-based REDCap application at the time of inclusion of the patient in the trial. The randomisation will be stratified by site. The study design is shown in figure 1. Patients randomised to the standard treatment arm will be treated according to the site’s routine practice—as preprocedural imaging, a CCT scan has to be performed; this can also be complemented with TEE at the discretion of the operator. For patients randomised to the computational simulation arm, the planning of the LAA closure will be performed according to the standard practice of the site integrated with a careful review of the FEops HEARTguide simulation results. The only prerequisite is that the preprocedural CCT scan has to be uploaded into the FEops HEARTguide platform in a pseudo-anonymised fashion. The results of the computational simulation will be provided to the operator within two working days, containing a range of options in terms of device size and implant position in the selected patient (figure 2). The operator should use the computational simulations as an additional preprocedural planning tool, aiming for a 10% to 25% compression of the Amulet lobe, complete LAA closure with full coverage of all trabeculations and a concave-shaped disc that is not retracted into the LAA neck (online supplementary video 1). The preprocedural planning should be performed integrating the standard planning with the analysis of the patient-specific computational results. For all patients, the LAA closure procedure should be performed following the routine practice of the site with TEE, micro-TEE or intracardiac echocardiography guidance, either in general or local anaesthesia. All patients should receive postprocedural antithrombotic medical therapy according to the participating sites’ routine practice, which is at the discretion of the treating physician. All patients enrolled in the study should have a postprocedural CCT scan at 3 months after the procedure, to assess for complete LAA closure, DRT and device position. All patients enrolled in the study should also have a clinical follow-up visit at 12 months after the procedure to record possible thromboembolic events or all-cause mortality (table 1A). The list of medical investigations required is shown in table 1B.
Figure 1

PREDICT-LAA study workflow. LAA, left atrial appendage.

Figure 2

FEops HEARTguide workflow and simulations. (Panel A) The preprocedural CT scan of the selected patient is uploaded on the web-based platform FEops HEARTguide and is—together with the in-house computational model of the Amulet device with adequate material properties for device and anatomy—used as input to the workflow. (Panel B) The received images are further processed to extract three-dimensional patient-specific anatomical reconstructions and landmarks for the procedure. This, in combination with the device model, serves as input for the computational finite element analysis. (Panel C) As output, several options in terms of device size and position are provided, including LAA wall apposition plots (colour-scale indicating the distance between the device and the anatomy), deformation visualisation and measurements (at the section indicated in red in panel C). (Panel D) The use of the simulation output in clinical practice: for one single patient, different simulations in terms of device size and position are provided to the operator, who can gain additional insights on the device–host interaction before the procedure.

Table 1A

Schedule for patients enrolled in PREDICT-LAA study

Standard treatment armComputational simulation arm
Preprocedural CT scanStandardUpload images to FEops HEARTguide
Preprocedural planningStandardStandard+FEops HEARTguide results
LAA closure procedureStandardStandard
Antithrombotic therapyStandardStandard
Postprocedural CT scanAt 3 months±30 daysAt 3 months±30 days
Follow-up visitAt 12 months±30 daysAt 12 months±30 days
Table 1B

Overview of investigations required for patients enrolled in the study

PreprocedureAt 3 monthsAt 12 months
Routine medical checkYesYesYes
12-Lead ECGYesYesYes
Transthoracic echocardiographyYesYesNo
Cardiac CT scanYesYesNo
PREDICT-LAA study workflow. LAA, left atrial appendage. FEops HEARTguide workflow and simulations. (Panel A) The preprocedural CT scan of the selected patient is uploaded on the web-based platform FEops HEARTguide and is—together with the in-house computational model of the Amulet device with adequate material properties for device and anatomy—used as input to the workflow. (Panel B) The received images are further processed to extract three-dimensional patient-specific anatomical reconstructions and landmarks for the procedure. This, in combination with the device model, serves as input for the computational finite element analysis. (Panel C) As output, several options in terms of device size and position are provided, including LAA wall apposition plots (colour-scale indicating the distance between the device and the anatomy), deformation visualisation and measurements (at the section indicated in red in panel C). (Panel D) The use of the simulation output in clinical practice: for one single patient, different simulations in terms of device size and position are provided to the operator, who can gain additional insights on the device–host interaction before the procedure. Schedule for patients enrolled in PREDICT-LAA study Overview of investigations required for patients enrolled in the study

Study endpoints

The primary endpoint of the PREDICT-LAA study is the percentage of patients with incomplete LAA closure (defined as any remaining contrast leakage into the LAA distal of the Amulet lobe) and/or a definite DRT at postprocedural CCT imaging at 3 months after the procedure. Definite DRT is defined as ‘high-grade’ hypoattenuating thickening at the atrial surface of the closure device—as previously described by Korsholm et al.9 Secondary endpoints evaluated in this study are listed in box 1. The CCT CoreLab evaluation will be performed at Rigshospitalet, Copenhagen, Denmark9; the readers of the CCT scan will be blinded from the baseline patient and procedural data as well as from patient’s randomisation arm. Incomplete closure of the LAA with remaining contrast leakage into the LAA distal of the Amulet lobe and/or presence of a definite device-related thrombus as assessed at postprocedural CCT at 3 months after LAA closure. Number of LAA closure devices used per procedure. Number of LAA closure device repositionings per procedure. Repositioning is defined as full deployment of the Amulet lobe in the LAA, followed by either full or partial recapture and redeployment of the lobe. Procedural time, radiation exposure and amount of contrast medium used per procedure. Procedure-related complications encompassing device embolisation, pericardial effusion requiring intervention, procedure-related stroke and procedure-related death within 7 days of the procedure. Different degrees of contrast leakage into the LAA. Full coverage of all LAA trabeculations by the Amulet device and a concave-shaped disc without retraction of the disc into the LAA neck as assessed at postprocedural CCT scan. Composite of all-cause death and thromboembolic event (transient ischaemic attack, ischaemic stroke or systemic embolism) at 12 months after randomisation. CCT, cardiac computed tomography; LAA, left atrial appendage.

Sample size calculation

The primary endpoint is expected to occur in 30% of patients in the standard treatment arm. An equal number of patients will be enrolled in both treatment arms. A 65% reduction of the primary endpoint requires inclusion of 174 patients in order to demonstrate superiority (power 0.8, α 0.05). Taking into account an estimated loss at follow-up of 10% to 15% of patients (due to mortality and inconclusive CCT imaging at 3 months postprocedure), the total sample size needed to demonstrate superiority has been calculated to be 200 patients. The primary endpoint will be analysed using Fisher’s exact test or a χ2 test, as required. Data/statistical analysis will be performed according to the ‘intention-to-treat’ principle as a first approach and ‘as-treated’ as a second approach.

Study organisation

PREDICT-LAA is an investigator-initiated, prospective, international, randomised clinical trial that will be executed under the academic leadership of investigators at Rigshospitalet University Hospital, Copenhagen (Denmark) and Institut Cardiovasculaire Paris Sud, Massy, Paris (France). The study will be conducted at up to 12 European and Canadian sites in compliance with the Declaration of Helsinki, International Conference on Harmonization, Good Clinical Practice Guidelines and applicable regulatory requirements. The first patient was enrolled in the study on 14 January 2020 and enrolment of all 200 patients is expected being completed in December 2021 with the last patient coming for the 1 year follow-up visit in December 2022. Five patients were enrolled as of the date of manuscript submission. The final study protocol and informed consent have been reviewed and approved by the local ethics boards, institutional review boards and corresponding health authorities of all participating sites. Rigshospitalet takes the sponsor role in this clinical trial. The study is funded by Abbott (Minneapolis, Minnesota, USA) and FEops NV (Ghent, Belgium). The academic sponsor will have full access to the trial data and will submit the results for publication in a peer-reviewed medical journal.

Conclusion

The PREDICT-LAA clinical trial is the first randomised clinical trial studying the efficacy of the preprocedural planning for percutaneous LAA closure, comparing a standard approach with a preprocedural planning that integrates patient-specific computational simulations. Hence, the PREDICT-LAA study will provide, as a first, randomised data on the possible added value of patient-specific computational simulations in the preprocedural planning for LAA closure.
  9 in total

1.  Percutaneous left atrial appendage closure vs warfarin for atrial fibrillation: a randomized clinical trial.

Authors:  Vivek Y Reddy; Horst Sievert; Jonathan Halperin; Shephal K Doshi; Maurice Buchbinder; Petr Neuzil; Kenneth Huber; Brian Whisenant; Saibal Kar; Vijay Swarup; Nicole Gordon; David Holmes
Journal:  JAMA       Date:  2014-11-19       Impact factor: 56.272

2.  Left Atrial Appendage Closure Guided by Personalized 3D-Printed Cardiac Reconstruction.

Authors:  James M Otton; Roberto Spina; Romina Sulas; Rajesh N Subbiah; Neil Jacobs; David W M Muller; Brendan Gunalingam
Journal:  JACC Cardiovasc Interv       Date:  2015-06       Impact factor: 11.195

3.  Validation of a computational model aiming to optimize preprocedural planning in percutaneous left atrial appendage closure.

Authors:  Alessandra M Bavo; Benjamin T Wilkins; Philippe Garot; Sander De Bock; Jacqueline Saw; Lars Søndergaard; Ole De Backer; Francesco Iannaccone
Journal:  J Cardiovasc Comput Tomogr       Date:  2019-08-20

Review 4.  Patient-specific computer simulation for transcatheter cardiac interventions: what a clinician needs to know.

Authors:  Peter de Jaegere; Giorgia Rocatello; Bernard D Prendergast; Ole de Backer; Nicolas M Van Mieghem; Ronak Rajani
Journal:  Heart       Date:  2019-03       Impact factor: 5.994

5.  Left atrial appendage occlusion simulation based on three-dimensional printing: new insights into outcome and technique.

Authors:  Vlad Ciobotaru; Nicolas Combes; Claire A Martin; Eloi Marijon; Eric Maupas; Augustin Bortone; Eric Bruguière; Jean-Benoit Thambo; Emmanuel Teiger; Pénélope Pujadas-Berthault; Julien Ternacle; Xavier Iriart
Journal:  EuroIntervention       Date:  2018-06-20       Impact factor: 6.534

6.  Detection of Device-Related Thrombosis Following Left Atrial Appendage Occlusion: A Comparison Between Cardiac Computed Tomography and Transesophageal Echocardiography.

Authors:  Kasper Korsholm; Jesper Møller Jensen; Bjarne Linde Nørgaard; Jens Erik Nielsen-Kudsk
Journal:  Circ Cardiovasc Interv       Date:  2019-09-13       Impact factor: 6.546

7.  Patient-Specific Computer Simulation to Elucidate the Role of Contact Pressure in the Development of New Conduction Abnormalities After Catheter-Based Implantation of a Self-Expanding Aortic Valve.

Authors:  Giorgia Rocatello; Nahid El Faquir; Gianluca De Santis; Francesco Iannaccone; Johan Bosmans; Ole De Backer; Lars Sondergaard; Patrick Segers; Matthieu De Beule; Peter de Jaegere; Peter Mortier
Journal:  Circ Cardiovasc Interv       Date:  2018-02       Impact factor: 6.546

Review 8.  Expert Recommendations on Cardiac Computed Tomography for Planning Transcatheter Left Atrial Appendage Occlusion.

Authors:  Kasper Korsholm; Sergio Berti; Xavier Iriart; Jacqueline Saw; Dee Dee Wang; Hubert Cochet; Danny Chow; Alberto Clemente; Ole De Backer; Jesper Møller Jensen; Jens Erik Nielsen-Kudsk
Journal:  JACC Cardiovasc Interv       Date:  2019-10-30       Impact factor: 11.195

9.  Percutaneous left atrial appendage occlusion for stroke prevention in atrial fibrillation: an update.

Authors:  O De Backer; S Arnous; N Ihlemann; N Vejlstrup; E Jørgensen; S Pehrson; T D W Krieger; P Meier; L Søndergaard; O W Franzen
Journal:  Open Heart       Date:  2014-06-06
  9 in total
  3 in total

1.  Clinical Impact of Preprocedural CT-Based 3D Computational Simulation of Left Atrial Appendage Occlusion with Amulet.

Authors:  Ian Buysschaert; Dries Viaene
Journal:  J Interv Cardiol       Date:  2021-07-26       Impact factor: 2.279

2.  Percutaneous closure of a 'whale tail' left atrial appendage with a Watchman FLX device and pre-procedural FEops HEARTguide patient-specific computational simulation: a case report.

Authors:  Francesca Maria Di Muro; Miroslava Stolcova; Carlo Di Mario; Francesco Meucci
Journal:  Eur Heart J Case Rep       Date:  2022-04-26

3.  The year in cardiovascular medicine 2021: interventional cardiology.

Authors:  Javier Escaned; Farouc A Jaffer; Julinda Mehilli; Roxana Mehran
Journal:  Eur Heart J       Date:  2022-02-03       Impact factor: 35.855

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.