Morgan A Lane1, Erik A Brownsword1, Jill S Morgan2, Ahmed Babiker3, Sharon A Vanairsdale2, G Marshall Lyon1, Aneesh K Mehta1, Jess M Ingersoll3, William G Lindsley4, Colleen S Kraft5.
Abstract
Bioaerosol samples were collected in an airborne infection isolation room, bathroom, and anteroom of a ventilated patient with coronavirus disease 2019. Twenty-eight samples were negative for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid, possibly due to the patient being on a closed-circuit ventilator or the efficiency of the air exchanges in the room.Entities:
Keywords: Airborne transmission; Hospital; Ventilator
Mesh:
Substances:
Year: 2020 PMID: 32763347 PMCID: PMC7402277 DOI: 10.1016/j.ajic.2020.07.033
Source DB: PubMed Journal: Am J Infect Control ISSN: 0196-6553 Impact factor: 2.918
Fig 1Location of the aerosol sampling within the patient room, patient bathroom, and anteroom.
Location and sampling time in patient room, bathroom, and anteroom
| Tripod designation | Tripod location | Tripod placement (start time) | Tripod removal (end time) | Sampling time (minutes) | SARS-CoV-2 detected (+/total) | Human RNase P gene detected (+/total) |
|---|---|---|---|---|---|---|
| T1 “Vent” | Patient room by ventilator system | 10:45 | 16:15 | 330 | 0/5 | 0/5 |
| T2 “Corner” | Patient room corner along ventilator wall | 10:45 | 16:30 | 345 | 0/5 | 2/5 |
| T3 “Door” | Patient room by anteroom door | 10:45 | 16:45 | 360 | 0/6 | 1/6 |
| T4 “Bathroom” | Patient room bathroom by toilet | 10:45 | 16:50 | 365 | 0/6 | 1/6 |
| T5 “Anteroom” | Anteroom by patient room door | 10:45 | 16:00 | 315 | 0/6 | 0/6 |