Bioaerosol sampling of a ventilated patient with COVID-19.

Morgan A Lane1, Erik A Brownsword1, Jill S Morgan2, Ahmed Babiker3, Sharon A Vanairsdale2, G Marshall Lyon1, Aneesh K Mehta1, Jess M Ingersoll3, William G Lindsley4, Colleen S Kraft5.   

Abstract

Bioaerosol samples were collected in an airborne infection isolation room, bathroom, and anteroom of a ventilated patient with coronavirus disease 2019. Twenty-eight samples were negative for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid, possibly due to the patient being on a closed-circuit ventilator or the efficiency of the air exchanges in the room.
Copyright © 2020 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Airborne transmission; Hospital; Ventilator

Mesh:

Substances:

Year:  2020        PMID: 32763347      PMCID: PMC7402277          DOI: 10.1016/j.ajic.2020.07.033

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


Coronavirus disease 2019 (COVID-19) has now been detected in nearly every country in the world. The causative agent of COVID-19 has been identified as the novel coronavirus severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Research is now being conducted to learn more about the transmission of the virus and the best ways to protect the general population, as well as health care personnel working at the frontlines of disease management. SARS-CoV-2 is believed to spread primarily through droplets or direct contact, with hospital-acquired transmission increasingly becoming a problem. Recent studies have shown that contact with contaminated surfaces is another possible method of transmission, with contamination of toilets and sinks being a priority in cleaning. , However, regular hospital cleaning procedures appear to kill the virus, and viable virus in fecal samples is rarely identified. , The virus may also be spread through aerosol-generating procedures, and it is possible that re-aerosolization of virus when health care workers remove personal protective equipment (PPE) increases exposure to the virus. With the number of cases and hospitalizations increasing, in order to protect health care personnel and uninfected patients in health care settings, it is important to understand the characteristics of aerosols containing SARS-CoV-2. While studies conducted during the pandemic have found aerosols containing virus within the health care setting, none have explicitly examined aerosols within the room of a patient on a ventilator. , While ventilators are assumed to be closed systems, in practice, they can be disconnected during clinical care or while moving the patient for positioning or procedures. , We sought to determine if aerosolized SARS-CoV-2 RNA could be found during the care of a ventilated patient who was being placed prone due to profound respiratory failure.

Methods

Bioaerosol sampling

Ten NIOSH BC 251 2-stage cyclone samplers were used. The NIOSH samplers separated particles into 3 size fractions, which are collected in a 15 mL centrifuge tube (>4 µm fraction), a 1.5 mL centrifuge tube (1-4 µm fraction) and on a filter cassette containing a 37-mm diameter, polytetrafluoroethylene filter with 2 µm pores (<1 µm fraction). Each sampler was connected with a 6.35-mm Tygon tubing to an air sampling pump (PCXR-4, SKC, Eighty Four, PA) at a 3.5 L/min flow rate. Two samplers were placed approximately 102 cm and 152 cm above the floor on each of 5 tripods. Three tripods were placed inside the patient room, 1 in the bathroom within the patient room, and 1 in the anteroom (Fig 1 ). The patient room samplers were placed next to the ventilator system (<2 ft away), in the corner along the same wall as the ventilator system, and by the anteroom door (<3 ft from the door). The anteroom sampler was placed <2 ft from the door to the patient room and the sampler in the bathroom was placed by the far wall (<2 ft from the toilet, <6 ft from the door). In an abundance of caution and to simplify disinfection, the sampler tripods were draped in plastic with holes cut out for the air intake and secured with tape. The pump cases were draped with a disposable underpad and secured to the tripods with tape.
Fig 1

Location of the aerosol sampling within the patient room, patient bathroom, and anteroom.

Location of the aerosol sampling within the patient room, patient bathroom, and anteroom. Following a 6-hour sampling period, collected samples from each sampler were processed as follows: 1) 1,000 µL viral transport medium was added to the 15 mL tube, the tube was vortexed, inverted and vortexed, then frozen at −80°C, 2) 400 µL viral transport medium was added to the 1.5 mL tube, the tube was vortexed, inverted and vortexed and frozen at −80°C, 3) sterile forceps were used to remove the filter from its cassette and place it in a 15 mL tube, 1,000 µL of viral transport medium was added to wet the entire filter, and the tube was vortexed and stored at −80°C. RNA extraction occurred on the m2000 (Abbott Molecular, Abbott Park, IL) with 600 µL of input sample volume, and sample elute of 50 uL. The extracted samples underwent real-time polymerase chain reaction (RT-PCR) for selected gene regions of the SARS-CoV-2 virus nucleocapsid (N1, N2, N3) and human RNase P gene using a laboratory developed protocol adapted from the protocol published by the Centers for Disease Control and Prevention. Following RNA extraction, a 20 µL reaction was set up containing 5 µL of sample RNA, 8.5 µL of nuclease-free water, 1.5 µL of combined primer/probe mix and 5µL of TaqPath 1-Step RT-qPCR Master Mix (ThermoFisher, Waltham, MA). Thermal cycling was performed at 25°C for 2 minutes followed by 50°C for 15 minutes, followed by an initial denaturation at 95°C for 2 minutes, followed by 45 cycles of amplification at 95°C for 3 seconds and 55.0°C for 30 seconds. A previously characterized SARS-CoV-2 sample was tested concurrently as a positive control. Fluorescence growth curves which cross the threshold line within 40 cycles (<40 Ct) were considered positive.

Patient room

Sampling took place in an ICU-level airborne infection isolation room (AIIR) in the Serious Communicable Diseases Unit at Emory University Hospital. The AIIR has negative air pressure relative to the anteroom (0.016-0.018 in of w.c.) with 20 air exchanges per hour, laminar flow across the patient bed, and HEPA filtration. The adjoining anteroom has negative air pressure relative to the hallway.

Patient

The patient was confirmed PCR positive for COVID-19 the day before sampling took place by both nasopharyngeal and oropharyngeal swabs. The patient's legal authorized representative provided informed consent under a protocol approved by the Emory IRB. During sampling, the patient was mechanically ventilated on a Hamilton ventilator, with HEPA end exhaust and in-line heat and moisture exchanger, via an 8.0 endotracheal tube with in-line, closed suction device. Between 2 and 5 multidisciplinary health care workers, including advanced practice providers, an attending physician, ICU nurses, and a respiratory therapist, were present in the patient room or anteroom during the entire 6-hour sampling period. With 5 health care personnel present in the patient room, the patient was re-positioned from prone to supine. However, the patient failed to tolerate supination, with decreasing oxygen saturation by SpO2 monitoring and increased peak pressures on the ventilator, and therefore required re-proning. During this time, there was one brief disconnection of the proximal and distal part of the ventilator hose.

Results

In total, 30 samples were collected, 3 from each sampler: one 15 mL centrifuge tube, one 1.5 mL centrifuge tube, and an additional 15 mL centrifuge tube containing the removed 37-mm filter. Two samples were unable to be used for testing: a 15 mL tube from the “Ventilator” tripod and a filter from the “Corner” tripod which fell on the floor. Of the 28 tested samples, 4 were positive for RP primer, indicating presence of human nucleic acid material. These included 2 samples from the patient room “Corner” 102 cm-high sampler, one sample from the room “Door”102 cm-high sampler and one sample from the “Bathroom” 152-high cm sampler (Table 1 ). None of the 28 samples tested were positive for SARS-CoV-2 nucleic acid.
Table 1

Location and sampling time in patient room, bathroom, and anteroom

Tripod designationTripod locationTripod placement (start time)Tripod removal (end time)Sampling time (minutes)SARS-CoV-2 detected (+/total)Human RNase P gene detected (+/total)
T1 “Vent”Patient room by ventilator system10:4516:153300/50/5
T2 “Corner”Patient room corner along ventilator wall10:4516:303450/52/5
T3 “Door”Patient room by anteroom door10:4516:453600/61/6
T4 “Bathroom”Patient room bathroom by toilet10:4516:503650/61/6
T5 “Anteroom”Anteroom by patient room door10:4516:003150/60/6
Location and sampling time in patient room, bathroom, and anteroom

Discussion

In order to protect health care personnel with appropriate PPE, there has been considerable discussion on what constitutes an aerosol-generating procedure. Our preliminary study shows that SARS-CoV-2 aerosols were not detected in an AIIR with a COVID-19 positive patient mechanically ventilated on a closed-suction device. This was particularly important because this patient was substantially manipulated through pronation and supination in the bed by many health care personnel during the 6 hours of sampling. His respiratory status was so poor that these aggressive measures were attempted to keep the patient able to be oxygenated. The health care workers were wearing powered air purifying respirators (PAPRs) as well as disposable gowns, 2 sets of gloves, and booties, in accordance with hospital policy. All PPE except for the PAPR were doffed in the patient room, with the PAPR being doffed in the anteroom. Some studies have detected low amounts of SARS-CoV-2 RNA in aerosol samples collected in health care settings where patients were breathing and coughing into the environment while others have not. , , , Our study was performed in an AIIR with laminar flow and a high air exchange rate with the patient on a ventilator with a HEPA filter. These early findings, based upon a single sampling event, suggest that the amount of airborne SARS-CoV-2 was very low. However, it is important to note the limitations of our study. First, we cannot comment on the possibility of virus transmission in this setting, because this study only measured aerosols in the air and did not examine other potential pathways for virus transmission. Further, the sampling may have been too dilute and the amount of RNA may have been below the limit of detection of 10 viral copies/mL. Second, aerosol sampling was conducted for only 1 patient during one 6-hour sampling period. Third, previous studies have shown that the filtration efficiency of ventilator exhaust filters varies widely, and thus these results cannot be assumed to apply to all ventilators and exhaust filters. Finally, although the patient was positive for COVID-19 in the upper respiratory tract and was diagnosed with acute respiratory distress syndrome, and therefore likely positive in the lower respiratory tract based on recent evidence, we cannot confirm that the patient was actively shedding virus on the day of sampling. Given we cannot understand the full extent of possible environmental contamination in the patient room with aerosol samples alone, surface sampling studies will be conducted along with any aerosol sampling in the future.
  9 in total

1.  Environmental contamination during tracheal suction. A comparison of disposable conventional catheters with a multiple-use closed system device.

Authors:  M Cobley; M Atkins; P L Jones
Journal:  Anaesthesia       Date:  1991-11       Impact factor: 6.955

2.  Measurement of airborne influenza virus in a hospital emergency department.

Authors:  Francoise M Blachere; William G Lindsley; Terri A Pearce; Stacey E Anderson; Melanie Fisher; Rashida Khakoo; Barbara J Meade; Owen Lander; Stephen Davis; Robert E Thewlis; Ismail Celik; Bean T Chen; Donald H Beezhold
Journal:  Clin Infect Dis       Date:  2009-02-15       Impact factor: 9.079

Review 3.  Preventing the transmission of pathogenic microbes during anesthesia.

Authors:  Antony R Wilkes
Journal:  Expert Rev Med Devices       Date:  2005-05       Impact factor: 3.166

4.  Air, Surface Environmental, and Personal Protective Equipment Contamination by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) From a Symptomatic Patient.

Authors:  Sean Wei Xiang Ong; Yian Kim Tan; Po Ying Chia; Tau Hong Lee; Oon Tek Ng; Michelle Su Yen Wong; Kalisvar Marimuthu
Journal:  JAMA       Date:  2020-04-28       Impact factor: 56.272

5.  Cross infection in an intensive care unit by Klebsiella pneumoniae from ventilator condensate.

Authors:  L J Gorman; L Sanai; A W Notman; I S Grant; R G Masterton
Journal:  J Hosp Infect       Date:  1993-01       Impact factor: 3.926

6.  Estimates of the severity of coronavirus disease 2019: a model-based analysis.

Authors:  Robert Verity; Lucy C Okell; Ilaria Dorigatti; Peter Winskill; Charles Whittaker; Natsuko Imai; Gina Cuomo-Dannenburg; Hayley Thompson; Patrick G T Walker; Han Fu; Amy Dighe; Jamie T Griffin; Marc Baguelin; Sangeeta Bhatia; Adhiratha Boonyasiri; Anne Cori; Zulma Cucunubá; Rich FitzJohn; Katy Gaythorpe; Will Green; Arran Hamlet; Wes Hinsley; Daniel Laydon; Gemma Nedjati-Gilani; Steven Riley; Sabine van Elsland; Erik Volz; Haowei Wang; Yuanrong Wang; Xiaoyue Xi; Christl A Donnelly; Azra C Ghani; Neil M Ferguson
Journal:  Lancet Infect Dis       Date:  2020-03-30       Impact factor: 25.071

7.  Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients.

Authors:  Po Ying Chia; Kristen Kelli Coleman; Yian Kim Tan; Sean Wei Xiang Ong; Marcus Gum; Sok Kiang Lau; Xiao Fang Lim; Ai Sim Lim; Stephanie Sutjipto; Pei Hua Lee; Than The Son; Barnaby Edward Young; Donald K Milton; Gregory C Gray; Stephan Schuster; Timothy Barkham; Partha Pratim De; Shawn Vasoo; Monica Chan; Brenda Sze Peng Ang; Boon Huan Tan; Yee-Sin Leo; Oon-Tek Ng; Michelle Su Yen Wong; Kalisvar Marimuthu
Journal:  Nat Commun       Date:  2020-05-29       Impact factor: 14.919

8.  The species Severe acute respiratory syndrome-related coronavirus: classifying 2019-nCoV and naming it SARS-CoV-2.

Authors: 
Journal:  Nat Microbiol       Date:  2020-03-02       Impact factor: 17.745

9.  Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and coronavirus disease-2019 (COVID-19): The epidemic and the challenges.

Authors:  Chih-Cheng Lai; Tzu-Ping Shih; Wen-Chien Ko; Hung-Jen Tang; Po-Ren Hsueh
Journal:  Int J Antimicrob Agents       Date:  2020-02-17       Impact factor: 5.283

  9 in total
  10 in total

1.  SARS-CoV-2 Droplet and Airborne Transmission Heterogeneity.

Authors:  Marta Baselga; Antonio Güemes; Juan J Alba; Alberto J Schuhmacher
Journal:  J Clin Med       Date:  2022-05-06       Impact factor: 4.964

Review 2.  SARS-CoV-2: a systematic review of indoor air sampling for virus detection.

Authors:  João Tito Borges; Liane Yuri Kondo Nakada; Milena Guedes Maniero; José Roberto Guimarães
Journal:  Environ Sci Pollut Res Int       Date:  2021-02-25       Impact factor: 5.190

3.  Bioaerosol sampling for SARS-CoV-2 in a referral center with critically ill COVID-19 patients March-May 2020.

Authors:  Morgan A Lane; Erik A Brownsword; Ahmed Babiker; Jessica M Ingersoll; Jesse Waggoner; Marie Ayers; Matthew Klopman; Timothy M Uyeki; William G Lindsley; Colleen S Kraft
Journal:  Clin Infect Dis       Date:  2021-01-28       Impact factor: 9.079

4.  Sampling for SARS-CoV-2 Aerosols in Hospital Patient Rooms.

Authors:  Morgan A Lane; Maria Walawender; Andrew S Webster; Erik A Brownsword; Jessica M Ingersoll; Candace Miller; Jesse Waggoner; Timothy M Uyeki; William G Lindsley; Colleen S Kraft
Journal:  Viruses       Date:  2021-11-23       Impact factor: 5.048

5.  The Environmental Deposition of Severe Acute Respiratory Syndrome Coronavirus 2 in Nosocomial Settings: Role of the Aerosolized Hydrogen Peroxide.

Authors:  Amani Alnimr; Aisha Alamri; Khaled F Salama; Mahmoud Radi; Huda Bukharie; Bashayer Alshehri; Ali A Rabaan; Mohammed Alshahrani
Journal:  Risk Manag Healthc Policy       Date:  2021-11-01

6.  Assessment of COVID-19 prevention and protection measures in hospitals.

Authors:  Albi Thomas; M Suresh
Journal:  Clean Eng Technol       Date:  2022-02-07

7.  Assessing impact of ventilation on airborne transmission of SARS-CoV-2: a cross-sectional analysis of naturally ventilated healthcare settings in Bangladesh.

Authors:  Ashley Styczynski; Caitlin Hemlock; Kazi Injamamul Hoque; Renu Verma; Chris LeBoa; Md Omar Faruk Bhuiyan; Auddithio Nag; Md Golam Dostogir Harun; Mohammed Badrul Amin; Jason R Andrews
Journal:  BMJ Open       Date:  2022-04-15       Impact factor: 3.006

Review 8.  SARS-CoV-2 air sampling: A systematic review on the methodologies for detection and infectivity.

Authors:  Priscilla G Silva; Pedro T B S Branco; Ruben R G Soares; João R Mesquita; Sofia I V Sousa
Journal:  Indoor Air       Date:  2022-08       Impact factor: 6.554

9.  SARS-CoV-2, other respiratory viruses and bacteria in aerosols: Report from Kuwait's hospitals.

Authors:  N Habibi; S Uddin; F Al-Salameen; S Al-Amad; V Kumar; M Al-Otaibi; N Abdul Razzack; A Shajan; F Shirshikar
Journal:  Indoor Air       Date:  2021-06-14       Impact factor: 6.554

Review 10.  Transmission of COVID-19 and other infectious diseases in public washrooms: A systematic review.

Authors:  Sotiris Vardoulakis; Daniela A Espinoza Oyarce; Erica Donner
Journal:  Sci Total Environ       Date:  2021-08-27       Impact factor: 7.963

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.