Accurate detection of spontaneous seizures using a generalized linear model with external validation.

Nicolas F Fumeaux1, Senan Ebrahim1, Brian F Coughlin1, Adesh Kadambi1, Aafreen Azmi1, Jen X Xu1, Maurice Abou Jaoude1, Sunil B Nagaraj2, Kyle E Thomson3, Thomas G Newell3, Cameron S Metcalf3, Karen S Wilcox3, Eyal Y Kimchi1, Marcio F D Moraes4, Sydney S Cash1.   

Abstract

OBJECTIVE: Seizure detection is a major facet of electroencephalography (EEG) analysis in neurocritical care, epilepsy diagnosis and management, and the instantiation of novel therapies such as closed-loop stimulation or optogenetic control of seizures. It is also of increased importance in high-throughput, robust, and reproducible pre-clinical research. However, seizure detectors are not widely relied upon in either clinical or research settings due to limited validation. In this study, we create a high-performance seizure-detection approach, validated in multiple data sets, with the intention that such a system could be available to users for multiple purposes.
METHODS: We introduce a generalized linear model trained on 141 EEG signal features for classification of seizures in continuous EEG for two data sets. In the first (Focal Epilepsy) data set consisting of 16 rats with focal epilepsy, we collected 1012 spontaneous seizures over 3 months of 24/7 recording. We trained a generalized linear model on the 141 features representing 20 feature classes, including univariate and multivariate, linear and nonlinear, time, and frequency domains. We tested performance on multiple hold-out test data sets. We then used the trained model in a second (Multifocal Epilepsy) data set consisting of 96 rats with 2883 spontaneous multifocal seizures.
RESULTS: From the Focal Epilepsy data set, we built a pooled classifier with an Area Under the Receiver Operating Characteristic (AUROC) of 0.995 and leave-one-out classifiers with an AUROC of 0.962. We validated our method within the independently constructed Multifocal Epilepsy data set, resulting in a pooled AUROC of 0.963. We separately validated a model trained exclusively on the Focal Epilepsy data set and tested on the held-out Multifocal Epilepsy data set with an AUROC of 0.890. Latency to detection was under 5 seconds for over 80% of seizures and under 12 seconds for over 99% of seizures. SIGNIFICANCE: This method achieves the highest performance published for seizure detection on multiple independent data sets. This method of seizure detection can be applied to automated EEG analysis pipelines as well as closed loop interventional approaches, and can be especially useful in the setting of research using animals in which there is an increased need for standardization and high-throughput analysis of large number of seizures.
© 2020 International League Against Epilepsy.

Entities:  

Keywords:  focal epilepsy; machine learning; model validation; quantitative EEG; seizure detection

Mesh:

Substances:

Year:  2020        PMID: 32761902      PMCID: PMC7953845          DOI: 10.1111/epi.16628

Source DB:  PubMed          Journal:  Epilepsia        ISSN: 0013-9580            Impact factor:   6.740


  39 in total

1.  Behavioral detection of tactile stimuli during 7-12 Hz cortical oscillations in awake rats.

Authors:  Michael C Wiest; Miguel A L Nicolelis
Journal:  Nat Neurosci       Date:  2003-09       Impact factor: 24.884

2.  A comparison of state and response entropy versus bispectral index values during the perioperative period.

Authors:  Paul F White; Jun Tang; Gladys F Romero; Ronald H Wender; Robert Naruse; Alexander Sloninsky; Robert Kariger
Journal:  Anesth Analg       Date:  2006-01       Impact factor: 5.108

3.  Inferring synaptic inputs from spikes with a conductance-based neural encoding model.

Authors:  Kenneth W Latimer; Fred Rieke; Jonathan W Pillow
Journal:  Elife       Date:  2019-12-18       Impact factor: 8.140

Review 4.  Seizure detection using scalp-EEG.

Authors:  Christoph Baumgartner; Johannes P Koren
Journal:  Epilepsia       Date:  2018-06       Impact factor: 5.864

Review 5.  Seizure prediction: the long and winding road.

Authors:  Florian Mormann; Ralph G Andrzejak; Christian E Elger; Klaus Lehnertz
Journal:  Brain       Date:  2006-09-28       Impact factor: 13.501

6.  Real-Time Epileptic Seizure Detection Using EEG.

Authors:  Lasitha S Vidyaratne; Khan M Iftekharuddin
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2017-04-25       Impact factor: 3.802

Review 7.  Mesial temporal lobe epilepsy: pathogenesis, induced rodent models and lesions.

Authors:  Alok K Sharma; Rachel Y Reams; William H Jordan; Margaret A Miller; H Leon Thacker; Paul W Snyder
Journal:  Toxicol Pathol       Date:  2007-12       Impact factor: 1.902

8.  Cyclicity of spontaneous recurrent seizures in pilocarpine model of temporal lobe epilepsy in rat.

Authors:  Karolien Goffin; Jari Nissinen; Koen Van Laere; Asla Pitkänen
Journal:  Exp Neurol       Date:  2007-03-16       Impact factor: 5.330

9.  Low-Power, 8-Channel EEG Recorder and Seizure Detector ASIC for a Subdermal Implantable System.

Authors:  Bruno G Do Valle; Sydney S Cash; Charles G Sodini
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2016-04-20       Impact factor: 3.833

10.  Assessment of acute morbidity and mortality in nonconvulsive status epilepticus.

Authors:  Bassel F Shneker; Nathan B Fountain
Journal:  Neurology       Date:  2003-10-28       Impact factor: 9.910

View more
  1 in total

Review 1.  Artificial intelligence in clinical and translational science: Successes, challenges and opportunities.

Authors:  Elmer V Bernstam; Paula K Shireman; Funda Meric-Bernstam; Meredith N Zozus; Xiaoqian Jiang; Bradley B Brimhall; Ashley K Windham; Susanne Schmidt; Shyam Visweswaran; Ye Ye; Heath Goodrum; Yaobin Ling; Seemran Barapatre; Michael J Becich
Journal:  Clin Transl Sci       Date:  2021-10-30       Impact factor: 4.689

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.