Literature DB >> 16368823

A comparison of state and response entropy versus bispectral index values during the perioperative period.

Paul F White1, Jun Tang, Gladys F Romero, Ronald H Wender, Robert Naruse, Alexander Sloninsky, Robert Kariger.   

Abstract

Cerebral monitoring indices are associated with a large degree of inter-patient variability and electrical signal interference during surgery. We designed this clinical study to test the hypothesis that use of the spectral entropy (Entropy) module is associated with less frequent intraoperative interference with the displayed indices than the bispectral index (BIS) monitor when used during general anesthesia with propofol and desflurane. Thirty consenting patients scheduled for major laparoscopic surgery procedures were enrolled in this prospective study. The elapsed time to obtain a baseline index value was recorded, as well as the simultaneous state entropy (SE), response entropy (RE), and BIS values at specific time intervals during the induction, maintenance, and emergence periods in patients administered a standardized general anesthetic technique. During the maintenance period, the changes in these indices were evaluated after a bolus dose of propofol (20 mg IV) and a 2% increase or decrease in the inspired concentration of desflurane. As expected, the baseline SE values were less than the RE and BIS values (88 +/- 2 versus 96 +/- 3 and 96 +/- 4, respectively). However, the SE and RE values correlated with the BIS value during the induction (r = 0.77 and 0.78, respectively) and emergence (r = 0.86 and 0.91, respectively) periods. The area under the receiver operating characteristic curve for detection of consciousness also indicated a similar performance of the SE (0.93 +/- 0.04) relative to the RE (0.98 +/- 0.04) and BIS (0.97 +/- 0.04). During the maintenance period, the responses to changes in propofol and desflurane concentrations were consistent with all three indices. Finally, the entropy indices were less interfered with by the electrocautery unit during the operation (12% versus 62% for the BIS monitor). Because the average selling prices of the Entropy and BIS disposable electrode strips (14.25 dollars versus 14.95 dollars USD, respectively) are comparable, we conclude that the Entropy module is a cost-equivalent alternative to the BIS monitor.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16368823     DOI: 10.1213/01.ane.0000183668.53139.fc

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  13 in total

1.  Comparing Entropy and the Bispectral index with the Ramsay score in sedated ICU patients.

Authors:  Carmen Hernández-Gancedo; David Pestaña; Hanna Pérez-Chrzanowska; Elena Martinez-Casanova; Antonio Criado
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

2.  EEG artifacts reduction by multivariate empirical mode decomposition and multiscale entropy for monitoring depth of anaesthesia during surgery.

Authors:  Quan Liu; Yi-Feng Chen; Shou-Zen Fan; Maysam F Abbod; Jiann-Shing Shieh
Journal:  Med Biol Eng Comput       Date:  2016-12-19       Impact factor: 2.602

3.  Signal persistence of bispectral index and state entropy during surgical procedure under sedation.

Authors:  Chanannait Paisansathan; Mukadder D Ozcan; Qaiser S Khan; Verna L Baughman; Mehmet S Ozcan
Journal:  ScientificWorldJournal       Date:  2012-02-02

4.  Spectral entropy as an objective measure of sedation state in midazolam-premedicated patients.

Authors:  Hany A Mowafi
Journal:  Saudi J Anaesth       Date:  2012-04

5.  Comparison of vital capacity induction with sevoflurane to intravenous induction with propofol in adult patients.

Authors:  Dhanashree H Dongare; Jyothi V Kale; Ramesh W Naphade
Journal:  Anesth Essays Res       Date:  2014 Sep-Dec

6.  CONSORT the effect of intraoperative dexmedetomidine on hemodynamic responses during emergence from nasotracheal intubation after oral surgery.

Authors:  Youn Yi Jo; Hong Soon Kim; Kyung Cheon Lee; Young Jin Chang; Youseok Shin; Hyun Jeong Kwak
Journal:  Medicine (Baltimore)       Date:  2017-04       Impact factor: 1.889

7.  Entropy is more resistant to artifacts than bispectral index in brain-dead organ donors.

Authors:  Johanna Wennervirta; Tapani Salmi; Markku Hynynen; Arvi Yli-Hankala; Anna-Maria Koivusalo; Mark Van Gils; Reino Pöyhiä; Anne Vakkuri
Journal:  Intensive Care Med       Date:  2006-11-08       Impact factor: 17.440

Review 8.  Spectral entropy monitoring for adults and children undergoing general anaesthesia.

Authors:  Anjolie Chhabra; Rajeshwari Subramaniam; Anurag Srivastava; Hemanshu Prabhakar; Mani Kalaivani; Saloni Paranjape
Journal:  Cochrane Database Syst Rev       Date:  2016-03-14

9.  Accurate detection of spontaneous seizures using a generalized linear model with external validation.

Authors:  Nicolas F Fumeaux; Senan Ebrahim; Brian F Coughlin; Adesh Kadambi; Aafreen Azmi; Jen X Xu; Maurice Abou Jaoude; Sunil B Nagaraj; Kyle E Thomson; Thomas G Newell; Cameron S Metcalf; Karen S Wilcox; Eyal Y Kimchi; Marcio F D Moraes; Sydney S Cash
Journal:  Epilepsia       Date:  2020-08-06       Impact factor: 6.740

10.  The effect of dexmedetomidine continuous infusion as an adjuvant to general anesthesia on sevoflurane requirements: A study based on entropy analysis.

Authors:  Chirag Ramanlal Patel; Smita R Engineer; Bharat J Shah; S Madhu
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-07
View more