Literature DB >> 3275599

Dynamic stereotactic radiosurgery.

E B Podgorsak1, A Olivier, M Pla, P Y Lefebvre, J Hazel.   

Abstract

Two radiosurgical procedures using a stereotactic frame and a linear accelerator X ray beam with a circular field diameter between 0.5 and 3 cm are presented. One technique is based on a single plane rotation (single plane radiosurgery) whereas the other uses simultaneous and continuous motions of both the gantry (approximately 360 degrees) and couch (approximately 180 degrees) during the radiosurgical procedure (dynamic radiosurgery). The dose, typically a few thousand cGy, is prescribed to the 90% isodose line which just covers the target volume. The dose fall-off outside the spherical target volume is considerably sharper for the dynamic rotation than for the single plane rotation, and is comparable to the dose fall-off obtained with the two presently known dedicated radiosurgical techniques: one based on focused cobalt beams and the other on proton beams. The dose fall-off in the dynamic radiosurgery discussed here is also comparable to that of previously described linear accelerator based multiple converging are techniques, making the dynamic radiosurgery an attractive alternative to presently known radiosurgical procedures. The radiation beam parameters are discussed and the stereotactic frame described. The dose distributions for both radiosurgical techniques are calculated in a single plane and then corrected for the attenuation effects in the stereotactic frame (approximately 2%) and for the effects of the dynamic rotation (approximately 2%). The skin doses are 0.7% and 2%, and the lens doses, if the beam passes through the eyes, are 2.5% and 3.5% for the dynamic rotation and single plane rotation, respectively. The scatter and leakage dose for the radiosurgical procedures is typically 0.2% to the patient's thyroid, 0.06% to the breast, and 0.02% to the gonads.

Entities:  

Mesh:

Year:  1988        PMID: 3275599     DOI: 10.1016/0360-3016(88)90059-4

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  15 in total

1.  Stereotactic linac radiosurgery for arteriovenous malformations.

Authors:  B G Kenny; E R Hitchcock; G Kitchen; A E Dalton; D A Yates; S V Chavda
Journal:  J Neurol Neurosurg Psychiatry       Date:  1992-07       Impact factor: 10.154

2.  Dosimetric accuracy of dynamic couch rotation during volumetric modulated arc therapy (DCR-VMAT) for primary brain tumours.

Authors:  Gregory Smyth; Philip M Evans; Jeffrey C Bamber; Henry C Mandeville; A Rollo Moore; Liam C Welsh; Frank H Saran; James L Bedford
Journal:  Phys Med Biol       Date:  2019-04-05       Impact factor: 3.609

Review 3.  Stereotactic radiosurgery: comparing different technologies.

Authors:  M Schwartz
Journal:  CMAJ       Date:  1998-03-10       Impact factor: 8.262

4.  Quality and safety in stereotactic radiosurgery and stereotactic body radiation therapy: can more be done?

Authors:  Timothy D Solberg; Paul M Medin
Journal:  J Radiosurg SBRT       Date:  2011

5.  Dynamic stereotactic radiosurgery in the palliative treatment of cerebral metastatic tumors.

Authors:  J L Caron; L Souhami; E B Podgorsak
Journal:  J Neurooncol       Date:  1992-02       Impact factor: 4.130

6.  Comparison of non-coplanar optimization of static beams and arc trajectories for intensity-modulated treatments of meningioma cases.

Authors:  Tiago Ventura; Humberto Rocha; Brigida da Costa Ferreira; Joana Dias; Maria do Carmo Lopes
Journal:  Phys Eng Sci Med       Date:  2021-10-07

7.  Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI.

Authors:  L R Schad; M Bock; K Baudendistel; M Essig; J Debus; M V Knopp; R Engenhart; W J Lorenz
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

8.  Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.

Authors:  D N Slatkin; P Spanne; F A Dilmanian; J O Gebbers; J A Laissue
Journal:  Proc Natl Acad Sci U S A       Date:  1995-09-12       Impact factor: 11.205

9.  Prescription to 50-75% isodose line may be optimum for linear accelerator based radiosurgery of cranial lesions.

Authors:  Bo Zhao; Jian-Yue Jin; Ning Wen; Yimei Huang; M Salim Siddiqui; Indrin J Chetty; Samuel Ryu
Journal:  J Radiosurg SBRT       Date:  2014

10.  Verification of the delivered patient radiation dose for non-coplanar beam therapy.

Authors:  Ivan Kutuzov; Timothy Van Beek; Boyd M C McCurdy
Journal:  J Appl Clin Med Phys       Date:  2021-05-22       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.