Literature DB >> 32736369

Monitoring bronchoalveolar lavage with electrical impedance tomography: first experience in a patient with COVID-19.

Yingyun Fu1, Rongrong Zou, Shouhong Wang, Junmin Wen, Lei Rong, Ming Tang, Baojun Yu, Fulan Cen, Zhanqi Zhao, Inéz Frerichs, Andy Adler, Yingxia Liu, Lei Liu.   

Abstract

OBJECTIVE: Patients with the novel coronavirus disease (COVID-19) often have airway secretions that severely compromise ventilation. This study investigates electrical impedance tomography (EIT) monitoring of a therapeutic bronchoalveolar lavage (BAL) in a patient with COVID-19. APPROACH: A patient with COVID-19 developed acute respiratory distress syndrome requiring mechanical ventilation. He received regional BAL to remove mucus in the small airways (20 ml × 5). Regional ventilation changes before BAL, 30 min after and in the following days, were monitored with EIT. MAIN
RESULTS: Regional ventilation worsened shortly after BAL and improved in the following days. The improvement of the oxygenation did not exactly match the ventilation improvement, which indicated a possible ventilation/perfusion mismatch. SIGNIFICANCE: Therapeutic BAL might improve regional ventilation for COVID-19 and EIT could be a useful tool at the bedside to monitor the ventilation treatment of COVID-19.

Entities:  

Mesh:

Year:  2020        PMID: 32736369     DOI: 10.1088/1361-6579/abab1b

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  Pulmonary pathophysiology development of COVID-19 assessed by serial Electrical Impedance Tomography in the MaastrICCht cohort.

Authors:  Serge J H Heines; Bas C T van Bussel; Melanie J Acampo-de Jong; Frank C Bennis; Rob J J van Gassel; Rald V M Groven; Nanon F L Heijnen; Ben J M Hermans; René Hounjet; Johan van Koll; Mark M G Mulder; Marcel C G van de Poll; Frank van Rosmalen; Ruud Segers; Sander Steyns; Ulrich Strauch; Jeanette Tas; Iwan C C van der Horst; Sander M J van Kuijk; Dennis C J J Bergmans
Journal:  Sci Rep       Date:  2022-08-25       Impact factor: 4.996

2.  Regional ventilation distribution in healthy lungs: can reference values be established for electrical impedance tomography parameters?

Authors:  Lin Yang; Meng Dai; Xinsheng Cao; Knut Möller; Mantas Dargvainis; Inéz Frerichs; Tobias Becher; Feng Fu; Zhanqi Zhao
Journal:  Ann Transl Med       Date:  2021-05

Review 3.  Imaging Pulmonary Blood Vessels and Ventilation-Perfusion Mismatch in COVID-19.

Authors:  Dnyanesh N Tipre; Michal Cidon; Rex A Moats
Journal:  Mol Imaging Biol       Date:  2022-01-18       Impact factor: 3.484

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.