Objective assessment of the combined effect of exomass-related- and motion artefacts in cone beam CT.

Matheus Lima Oliveira1, Amanda P Candemil1, Deborah Q Freitas1, Francisco Haiter-Neto1, Ann Wenzel2, Rubens Spin-Neto2.   

Abstract

OBJECTIVES: To assess quantitatively the combined effect of exomass-related- and motion artefacts on voxel value parameters in cone beam CT (CBCT).
METHODS: A cylindrical phantom was manufactured, containing 21 tubes filled with a radiopaque solution, allowing the inclusion of three titanium implants in the periphery to induce exomass-related artefacts. The phantom was mounted on a robot simulating 0.75-, 1.5-, and 3 mm movements (nodding/lateral rotation/tremor). CBCT images with/without exomass and with/without movements were acquired in duplicate in three units: Cranex 3Dx, Orthophos SL-3D, and X1 (with motion-artefact correction). A cylindrical volume of interest was defined in each tube and voxel value mean and standard deviation were assessed. For each CBCT volume, the 21 mean voxel values were averaged providing the overall mean voxel value (MVV), and the standard deviation (among the 21 values) was calculated providing overall voxel value inhomogeneity (VVI). The standard deviation from each of the 21 volumes-of-interest were averaged, providing overall image noise (IN). The effect of the diverse tested situations was inferred from a repeated-measures analysis of variance, followed by Sidak's test (α = 0.05).
RESULTS: Overall, images acquired with exomass showed significantly (p ≤ 0.05) lower MVV, and higher VVI and IN. Motion artefacts aggravated exomass-related alterations. MVV and VVI were mostly affected by 3 mm nodding movements. Motion-artefact correction eliminated the deleterious effect of movement.
CONCLUSIONS: CBCT voxel-value parameters are altered by exomass-related artefacts, and this finding is aggravated in the presence of motion artefacts. Motion-artefact correction effectively eliminated the deleterious impact of movement.

Entities:  

Keywords:  Cone beam computed tomography; artefacts; image quality; patient movement

Mesh:

Year:  2020        PMID: 32706986      PMCID: PMC7780835          DOI: 10.1259/dmfr.20200255

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  17 in total

1.  Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials.

Authors:  Polyane Mazucatto Queiroz; Matheus Lima Oliveira; Francisco Carlos Groppo; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  Clin Oral Investig       Date:  2017-05-23       Impact factor: 3.573

2.  Influence of exposure factors on the variability of CBCT voxel values: a phantom study.

Authors:  M L Oliveira; D Q Freitas; G M B Ambrosano; F Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2014-05-28       Impact factor: 2.419

3.  Metallic materials in the exomass impair cone beam CT voxel values.

Authors:  Amanda P Candemil; Benjamin Salmon; Deborah Q Freitas; Glaucia Mb Ambrosano; Francisco Haiter-Neto; Matheus L Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2018-03-27       Impact factor: 2.419

4.  Distribution of metal artifacts arising from the exomass in small field-of-view cone beam computed tomography scans.

Authors:  Amanda P Candemil; Benjamin Salmon; Deborah Queiroz Freitas; Francisco Haiter-Neto; Matheus Lima Oliveira
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2020-02-11

5.  Impact of motion artefacts and motion-artefact correction on diagnostic accuracy of apical periodontitis in CBCT images: an ex vivo study in human cadavers.

Authors:  R Spin-Neto; C Kruse; L Hermann; L-L Kirkevang; A Wenzel
Journal:  Int Endod J       Date:  2020-06-11       Impact factor: 5.264

6.  Patient movement characteristics and the impact on CBCT image quality and interpretability.

Authors:  Rubens Spin-Neto; Cláudio Costa; Daniela Mra Salgado; Nataly Rm Zambrana; Erik Gotfredsen; Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2017-10-20       Impact factor: 2.419

7.  Metal artifact reduction in cone beam computed tomography using forward projected reconstruction information.

Authors:  Manuel Meilinger; Christian Schmidgunst; Oliver Schütz; Elmar W Lang
Journal:  Z Med Phys       Date:  2011-05-06       Impact factor: 4.820

8.  Are metal artefact reduction algorithms effective to correct cone beam CT artefacts arising from the exomass?

Authors:  Amanda Pelegrin Candemil; Benjamin Salmon; Deborah Queiroz Freitas; Glaucia Maria Bovi Ambrosano; Francisco Haiter-Neto; Matheus Lima Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2019-01-28       Impact factor: 2.419

9.  Cone beam CT image artefacts related to head motion simulated by a robot skull: visual characteristics and impact on image quality.

Authors:  R Spin-Neto; J Mudrak; L H Matzen; J Christensen; E Gotfredsen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

10.  Impact of movement and motion-artefact correction on image quality and interpretability in CBCT units with aligned and lateral-offset detectors.

Authors:  Gustavo Machado Santaella; Ann Wenzel; Francisco Haiter-Neto; Pedro Luiz Rosalen; Rubens Spin-Neto
Journal:  Dentomaxillofac Radiol       Date:  2019-09-24       Impact factor: 2.419

View more
  2 in total

1.  Effect of the Field of View Size on CBCT Artifacts Caused by the Presence of Metal Objects in the Exomass.

Authors:  Yaser Safi; Mitra Ghazizadeh Ahsaie; Maede Jafarian Amiri
Journal:  Int J Dent       Date:  2022-09-09

2.  Head motion and perception of discomfort by young children during simulated CBCT examinations.

Authors:  Rubens Spin-Neto; Louise Hauge Matzen; Louise Hermann; João Marcus de Carvalho E Silva Fuglsig; Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2020-10-30       Impact factor: 2.419

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.