Use of new-generation hybrid contact lenses for managing challenging corneas.

Ibrahim Inan Harbiyeli1, Elif Erdem1, Puren Isik1, Meltem Yagmur1, Reha Ersoz1.   

Abstract

INTRODUCTION: To evaluate the safety and efficacy of new-generation hybrid contact lenses (HCL) among patients with irregular astigmatism.
METHODS: Medical records of 25 patients fit with new-generation HCL (Eyebrid® and AirFlex®) were retrospectively reviewed. The data collected included etiology of irregular astigmatism, uncorrected visual acuity, manifest refraction, spectacle-corrected visual acuity (S-CDVA), steep / flat keratometric values, corneal astigmatism, records of rigid / soft CL fitted before HCL, all parameters of the trial lenses, and the final prescribed HCL parameters and HCL-CDVA.
RESULTS: The study included 34 eyes from 25 patients (nine females and 16 males) with an average age of 29 ± 13 (ranging from 8-56) years. In total, 25 eyes with keratoconus, four with post - keratoplasty astigmatism, three with irregular astigmatism due to corneal trauma and two with residual astigmatism after radial keratotomy were fit with HCL. The mean S-CDVA (logMAR) improved significantly from 0.76 ± 0.41 to 0.14 ± 0.15 with HCL (p < 0.01). The most common indication for HCL was inability to fit with rigid gas permeable (RGP) lenses (22 eyes). The average number of lenses to successful fit was 1.4 (mode, 1; median, 1) and ideal fit was achieved with the first trial lens in 25 eyes (73%). Seven patients (nine eyes, 36%) discontinued lens use within the first 6 months because of discomfort (six eyes, 24%), ocular allergy (two eyes, 8%) and tearing of contact lens (one eye, 4%). DISCUSSION: New-generation HCL may be a suitable option for fitting challenging corneas with irregular astigmatism that cannot be rehabilitated efficiently with rigid lenses.

Entities:  

Keywords:  Challenging corneas; irregular astigmatism; new-generation hybrid contact lens

Mesh:

Year:  2020        PMID: 32668981     DOI: 10.1177/1120672120942757

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  1 in total

1.  Refractive Correction After Penetrating Keratoplasty by a New Soft Contact Lens with a Special Design for Astigmatism: A Case Report.

Authors:  Tomoto Kasahara; Hiroshi Toshida; Kohei Ichikawa; Yusuke Matsuzaki; Junji Ono
Journal:  Int Med Case Rep J       Date:  2022-04-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.