Xiaoke Yao1, Lingna Wu2, Jianhua Li1, Wengang Huang1, Chongwen Wang1, Zuchao Gu1, Yue Wang3. 1. Department of Orthopedics, Chengdu First People's Hospital, Chengdu Sichuan, 610041, P.R.China. 2. Intensive Care Unit, Chengdu First People's Hospital, Chengdu Sichuan, 610041, P.R.China. 3. Department of Orthopedics, Sichuan Academy of Medical Science & Sichuan Provincial People's Hospital, Chengdu Sichuan, 610072, P.R.China.
Abstract
OBJECTIVE: To investigate the effectiveness of volar oblique T-type locking plate and raft screws reduction and fixation in the treatment of extreme distal radius fractures. METHODS: Between July 2014 and July 2018, 15 patients with extreme distal radius fractures were treated with volar oblique T-type locking plate and raft screws reduction and fixation. There were 6 males and 9 females, aged from 30 to 66 years with an average age of 56.6 years. The cause of injury was falling from height in 2 cases and falling in 13 cases. All of them were fresh closed injuries. The fractures were rated as type 23C1 in 8 cases and as type 23C2 in 7 cases according to AO/Orthopaedic Trauma Association (AO/OTA) classification. There were 7 cases of ulnar styloid process fracture and 2 cases of distal radioulnar joint instability. The time from injury to operation was 6 to 9 days with an average of 7.3 days. The fracture healing and the radial height, palm inclination, and ulnar deviation were observed by X-ray reexamination. Cooney score was used to evaluate the effectiveness. RESULTS: All incisions healed by first intention. All patients were followed up 12-24 months, with an average of 14.6 months. X-ray films showed that all fractures healed, and the healing time ranged from 5 to 10 months, with an average of 8.2 months. No internal fixation failure or secondary fracture displacement occurred. At last follow-up, the radial height, palm inclination, and ulnar deviation recovered well, and the differences between pre- and post-operation were significant ( P<0.05). The pain, function, activity, and grip strength scores and the total score of Cooney score were significantly higher than those before operation ( P<0.05). There were 11 cases of excellent, 3 cases of good, and 1 case of good, with an excellent and good rate of 93%. CONCLUSION: For extreme distal radius fractures, the volar oblique T-type locking plate and raft screws reduction and fixation can restore the radialheight, palm inclination, and ulnar deviation, fix firmly, and recover the wrist joint function exercise early, and obtain satisfactory effectiveness.
OBJECTIVE: To investigate the effectiveness of volar oblique T-type locking plate and raft screws reduction and fixation in the treatment of extreme distal radius fractures. METHODS: Between July 2014 and July 2018, 15 patients with extreme distal radius fractures were treated with volar oblique T-type locking plate and raft screws reduction and fixation. There were 6 males and 9 females, aged from 30 to 66 years with an average age of 56.6 years. The cause of injury was falling from height in 2 cases and falling in 13 cases. All of them were fresh closed injuries. The fractures were rated as type 23C1 in 8 cases and as type 23C2 in 7 cases according to AO/Orthopaedic Trauma Association (AO/OTA) classification. There were 7 cases of ulnar styloid process fracture and 2 cases of distal radioulnar joint instability. The time from injury to operation was 6 to 9 days with an average of 7.3 days. The fracture healing and the radial height, palm inclination, and ulnar deviation were observed by X-ray reexamination. Cooney score was used to evaluate the effectiveness. RESULTS: All incisions healed by first intention. All patients were followed up 12-24 months, with an average of 14.6 months. X-ray films showed that all fractures healed, and the healing time ranged from 5 to 10 months, with an average of 8.2 months. No internal fixation failure or secondary fracture displacement occurred. At last follow-up, the radial height, palm inclination, and ulnar deviation recovered well, and the differences between pre- and post-operation were significant ( P<0.05). The pain, function, activity, and grip strength scores and the total score of Cooney score were significantly higher than those before operation ( P<0.05). There were 11 cases of excellent, 3 cases of good, and 1 case of good, with an excellent and good rate of 93%. CONCLUSION: For extreme distal radius fractures, the volar oblique T-type locking plate and raft screws reduction and fixation can restore the radialheight, palm inclination, and ulnar deviation, fix firmly, and recover the wrist joint function exercise early, and obtain satisfactory effectiveness.
Authors: Fei Yin; Yongjun Rui; Fengfeng Li; Jun Liu; Yongwei Wu; Yao Lu; Yunhong Ma; Zhenzhong Sun Journal: Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi Date: 2017-12-15
Authors: Lukas Daniel Iselin; Anne-Sophie Massy-Budmiger; Raoul A Droeser; Tobias R Mett; Reto Babst; Daniel A Rikli Journal: Medicine (Baltimore) Date: 2016-05 Impact factor: 1.889