Claudio Antunes Junior1, Emílio Graciliano Ferreira Mercuri1, Ana Paula Gebert de Oliveira Franco2, Manoella Costa3, Leandro Zen Karam2, Hypolito José Kalinowski4, Osnara Maria Mongruel Gomes3.
Abstract
Contraction due to polymerization of dental resin can cause failure on the adhesive interfaces, can lead to problems such as the appearance of gaps in the interfaces, postoperative sensitivity, pulp damage and the return of the caries. The objective of this work is the study of stresses on the dental adhesive that are generated by the process shrinkage of resin associated with biting forces. A laboratory experiment measured the strains and temperature inside the FiltekTM Bulk Fill Flow resin during the process of polymerization using Fiber Bragg Grating sensors in an ex vivo tooth. From tomographic images a three-dimensional geometric model of the tooth was reconstructed. A pre-tension was calibrated to simulate the residual contraction on the resin 3 D model. Finally, an Finite Element Method analysis was performed to access the adhesive stresses at the interface enamel/dentin with the adhesive, considering as loading the residual polymerization contraction of the dental resin and also biting loads. The model was able to represented the strain obtained in the laboratory experiment. The results of the stress analysis shows that the outer regions of adhesive are more prone to failure, as veried by dental surgeons in clinical practice.Keywords: Bulk-fill resin; dental adhesives; polymerization shrinkage stress
Mesh:
Substances:
Year: 2020 PMID: 32657618 DOI: 10.1080/10255842.2020.1789607
Source DB: PubMed Journal: Comput Methods Biomech Biomed Engin ISSN: 1025-5842 Impact factor: 1.763