Literature DB >> 32654056

Clinical outcomes of revision with retrograde intermedullary nailing for failed plating of distal femoral fractures: a retrospective study.

Yi Yuan1, Bing Luo1, Qi Hao1, Jun Yuan1, Gang-Bo Qu1, Pan-Deng Hao1, Zhi-Jiang Zeng1, Jia-Fu Yang2, Zu-Jian Xu3.   

Abstract

PURPOSE: To assess the feasibility and effectiveness of retrograde intramedullary nail (RIN) revision surgeries for locking compression plate (LCP) failure in distal femoral fractures.
METHODS: This retrospective study included 13 patients who suffered from metalwork failures after they initially underwent open reduction and LCP fixation. In patients who eventually underwent RIN revision from January 2014 to December 2016, range of motion (ROM) and Hospital for Special Surgery (HSS) scores obtained before surgery and at the final follow-up time were analysed.
RESULTS: The average operative time was 155 minutes (range, 120-210 minutes), and the average blood loss volume was 650 ml (range, 200-1350 ml). There were two cases of complications (15.38%): one was calf muscle vein thrombosis, and the other was a superficial infection. No deep tissue infection or deep vein thrombosis was observed post-operatively. The average follow-up time was 16 months (range, 12-24 months). All fractures healed in a mean of 6.5 months (range, 4-12 months), and one patient underwent an additional bone graft surgery that did not involve a bone graft during the RIN revision operation (this eventually healed at 12 months post-operatively). The mean ROM before the operation was 86.92 ± 12.34°. At the final follow-up, the mean ROM was 112.69 ± 9.27°. There was a significant difference between pre-operative and post-operative ROM (P < 0.01). The mean HSS score improved significantly from 38.85 ± 9.62 points pre-operatively to 79.62 ± 5.42 points post-operatively. There was a significant difference between pre-operative and post-operative HSS scores (P < 0.01).
CONCLUSIONS: RIN revision surgery achieved excellent clinical results in patients with LCP failure.

Entities:  

Keywords:  Distal femoral fracture; Failure, retrograde intramedullary nail; Locking compression plate; Revision

Mesh:

Year:  2020        PMID: 32654056     DOI: 10.1007/s00264-020-04621-x

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  1 in total

Review 1.  Dual Plating of the Distal Femur: Indications and Surgical Techniques.

Authors:  Arnab Sain; Vijay Sharma; Kamran Farooque; Muthukumaran V; Kirubakaran Pattabiraman
Journal:  Cureus       Date:  2019-12-27
  1 in total
  2 in total

1.  Application of a double reverse traction repositor in the retrograde intramedullary nailing of distal femur fractures.

Authors:  Xiaodong Lian; Kuo Zhao; Wei Chen; Junzhe Zhang; Junyong Li; Hongyu Meng; Zhiyong Hou; Yingze Zhang
Journal:  J Orthop Surg Res       Date:  2021-03-03       Impact factor: 2.359

2.  [Clinical application of lower extremity axial distractor in closed reduction and retrograde intramedullary nail fixation of distal femoral fractures].

Authors:  Nan Zhou; Mingliang Ma; Hongzhi Liu; Dongyang Zhao; Zhigang Wang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-06-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.