Literature DB >> 32653962

Reusable optofluidic point-of-care testing platform with lyophilized specific antibody for fluorescence detection of cholylglycine in serum.

Jiayao Liu1, Wenjuan Xu1, Anna Zhu2, Haoxiang Kang3, Yu Cao3, Feng Long4.   

Abstract

A reusable optofluidic point-of-care testing platform (OPOCT) was successfully constructed through integrating evanescent wave fluorescence technology into an all-fiber-based optofluidic system. The compact design of the OPOCT allows it to be portable and suitable for on-site sensitive determination of biomarkers in serum without complicated and costly procedures. The sensitivity of 90.9 pM for antibody determination is observed thanks to the high transmission efficiency of excitation light and fluorescence in the OPOCT. The affinity constant between cholylglycine (CG) and anti-CG antibody was quantified using this platform based on the proposed theory. Using the lyophilized fluorescence-labeled specific antibody and reusable fiber optic biosensor, the OPOCT is applied to the one-step sensitive determination of CG in serum, which eliminates the dearth associated with liquid reagent handling, disposable biosensors, and user intervention. A limit of detection of 0.025 μg/mL for CG is obtained, which is far more than adequate for meeting diagnostic requirements. The matrix effect of serum samples on the evanescent wave-based optofluidic biosensor can be effectively reduced by simple dilution of serum samples. The performance of the OPOCT also compared favorably with that of a commercial turbidimetric inhibition immunoassay through analyzing multiple serum samples. This platform is ready to expand to measure any other biomarker by using its specific antibody. The simplicity, sensitivity, cost-effectiveness, and robustness of the OPOCT enable the early diagnosis of disease and making a timely clinical decision. Graphical abstract .

Entities:  

Keywords:  Cholylglycine; Evanescent wave fluorescence; Immunoassay; Optofluidic; Point-of-testing

Mesh:

Substances:

Year:  2020        PMID: 32653962     DOI: 10.1007/s00604-020-04424-2

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  2 in total

Review 1.  Immunosensor of Nitrofuran Antibiotics and Their Metabolites in Animal-Derived Foods: A Review.

Authors:  Jingze Jia; Hongxia Zhang; Jiayi Qu; Yuanfeng Wang; Naifeng Xu
Journal:  Front Chem       Date:  2022-06-01       Impact factor: 5.545

Review 2.  Application of Microfluidics in Immunoassay: Recent Advancements.

Authors:  Yuxing Shi; Peng Ye; Kuojun Yang; Jie Meng; Jiuchuan Guo; Zhixiang Pan; Qiaoge Bayin; Wenhao Zhao
Journal:  J Healthc Eng       Date:  2021-07-15       Impact factor: 2.682

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.