Literature DB >> 32647768

Comparison of Early-Compartment Correction Equations for GFR Measurements.

Pierre Delanaye1,2, Laurence Dubourg3, Martin Flamant4, Eric Yayo5, Justine B Bukabau6, Emmanuelle Vidal-Petiot4, Sandrine Lemoine3, Etienne Cavalier7, Elke Schaeffner8, Dagui Monnet5, Ernest K Sumaili6, Natalie Ebert8, Hans Pottel9.   

Abstract

Entities:  

Year:  2020        PMID: 32647768      PMCID: PMC7335969          DOI: 10.1016/j.ekir.2020.04.015

Source DB:  PubMed          Journal:  Kidney Int Rep        ISSN: 2468-0249


× No keyword cloud information.
Measuring the glomerular filtration rate (GFR) remains indicated in specific patients and/or specific clinical contexts., For practical reasons, plasma clearances are preferred instead of urinary clearance. In most centers, the plasma clearance is calculated from exogenous marker concentrations obtained during the excretion phase (the second or slow GFR compartment), which is the most important for GFR determination. However, GFR is systematically overestimated because the part of the area under the curve (AUC) from the first (or early) compartment, which corresponds to the distribution of the marker in the body, is neglected. Because the AUC of the first compartment is not measured but estimated, it is prone to some imprecision, notably in high GFR ranges. Moreover, this overestimation can be corrected using various published mathematical models published by Chantler (C), Bröchner-Mortensen (BM), Fleming (F), Jodal-Bröchner-Mortensen (JBM), and Ng (N) (equations are given in Supplementary Table S1).3, 4, 5, 6, 7 Few data are available on the comparison between these models. This is the goal of the current study. From 6 different cohorts,, we collected results of measured GFR by plasma clearance (iohexol or 51Cr−ethylenediamine tetraacetic acid [EDTA]) and compared the results obtained with the different correction equations (methods are described in detail in the Supplementary Methods). Among the 5459 participants, the mean age was 53 ± 17 years, and 42.9% were women. Mean height and body weight were 168 ± 10 cm and 73 ± 17 kg, respectively. Mean body mass index (BMI) and body surface area (BSA) were 26 kg/m2 ± 6 kg/m2 and 1.85 m2 ± 0.24 m2, respectively. Mean measured GFR (mGFR) with C, BM, F, JBM, and Ng was 63 ml/min per 1.73 m2 ± 28 ml/min per 1.73 m2, 64 ml/min per 1.73 m2 ± 25 ml/min per 1.73 m2, 63 ml/min per 1.73 m2 ± 24 ml/min per 1.73 m2, 64 ml/min per 1.73 m2 ± 25 ml/min per 1.73 m2, and 65 ml/min per 1.73 m2 ± 26 ml/min per 1.73 m2, respectively. Lin’s concordance correlation coefficient and biases are described in detail in Supplementary Table S2 in the Supplementary Material, but all comparisons showed almost perfect correlation (with concordance correlation coefficients >0.99). Regarding bias, all comparisons showed that bias was not relevant from a clinical perspective (the highest bias being 3 ml/min per 1.73 m2). All concordance within 10% and 5% are given in Table 1. Concordance within 10% is 100% for all comparisons, except when C equation is considered. Within 5% concordance was also close to 100% for all equations, except between F and N and when the C equation is considered in the comparison. Subanalyses (see Supplemental Material) were repeated in subgroups according to GFR levels in Supplementary Table S3 (based on the BM method in 6 categories: >130 ml/min per 1.73 m2, 90−130 ml/min per 1.73 m2, 60−90 ml/min per 1.73 m2, 45−60 ml/min per 1.73 m2, 30−45 ml/min per 1.73 m2, and ≤30 ml/min per 1.73 m2), sex in Supplementary Table S4, BMI in Supplementary Table S5 (<18.5 kg/m2, 18.5−25 kg/m2, 25−30 kg/m2, 30−35 kg/m2, 35−40 kg/m2, and ≥40 kg/m2, respectively), and age in Supplementary Table S6 (categorized in decades). Conclusions were not different from those of the total cohort when analyses were made according to sex or BMI. Only the variable GFR level influenced concordance, with less concordance in high GFR levels, even if results were still quite similar between BM and F, BM and JBM, and F and JBM. Excluding results from the C equation which is, once again, the most discrepant, we observed a discordance of more than 5% when the slow GFR was above 290, 290, 155, 290, 117, and 128 ml/min per 1.73 m2 comparing BM-F, BM-JBM, BM-N, F-JBM, F-N, and JBM-N, respectively.
Table 1

Concordance within 10% (above diagonal) and within 5% (below diagonal)

CBMFJBMN
C97.196.896.291.7
BM51.9100100100
F59.6100100100
JBM54.3100100100
N37.498.890.798.9

BM, Bröchner-Mortensen; C, Chantler; F, Fleming; JBM, Jodal-Bröchner-Mortensen; N, Ng.

All results are expressed as percentages.

Concordance within 10% (above diagonal) and within 5% (below diagonal) BM, Bröchner-Mortensen; C, Chantler; F, Fleming; JBM, Jodal-Bröchner-Mortensen; N, Ng. All results are expressed as percentages. To the best of our knowledge, the current, multicentric study is the largest one comparing the different equations to correct the overestimation of the GFR obtained from the slow compartment. Two important conclusions should be drawn. First, the method proposed by Chantler in 1969 deviated most from all other methods. It can be reasonably presumed that this method was an oversimplification (C correction is just a linear correction), and we recommend that it should be abandoned. Second, all other models give very similar results, except at high GFR levels. The BM correction is the mostly used in the literature with iohexol and 51Cr-EDTA, whereas the F model is mostly used with 99Tc−diethylene triamine pentaacetic acid (DTPA), but obviously all these equations are interchangeable. More discrepancies can be observed at very high GFR levels. However, these discrepancies are observed at GFR levels which are higher than the threshold usually considered for the diagnosis of hyperfiltration, and therefore the clinical impact of such discrepancies is limited. BM correction is known to underestimate renal clearance at such high GFR levels. The performance of other equations at such high levels is not well known. The main limitation of the current analysis is the absence of renal/urinary clearance and/or plasma samples in the first (or early) compartment. Thus, we can assert that all equations, except the C one, are equivalent when measured GFR is lower than 130 ml/min 1.73 m2, but it remains difficult to know which one is the most accurate in the highest range of GFR. Further studies in this specific range of GFR are still required.

Disclosure

All the authors declared no competing interests.
  9 in total

1.  Guidelines for the measurement of glomerular filtration rate using plasma sampling.

Authors:  John S Fleming; Maureen A Zivanovic; Glen M Blake; Maria Burniston; Philip S Cosgriff
Journal:  Nucl Med Commun       Date:  2004-08       Impact factor: 1.690

2.  Single- versus multiple-sample method to measure glomerular filtration rate.

Authors:  Pierre Delanaye; Martin Flamant; Laurence Dubourg; Emmanuelle Vidal-Petiot; Sandrine Lemoine; Etienne Cavalier; Elke Schaeffner; Natalie Ebert; Hans Pottel
Journal:  Nephrol Dial Transplant       Date:  2018-10-01       Impact factor: 5.992

3.  A simple method for the determination of glomerular filtration rate.

Authors:  J Bröchner-Mortensen
Journal:  Scand J Clin Lab Invest       Date:  1972-11       Impact factor: 1.713

4.  Estimation of glomerular filtration rate from plasma clearance of 51-chromium edetic acid.

Authors:  C Chantler; T M Barratt
Journal:  Arch Dis Child       Date:  1972-08       Impact factor: 3.791

5.  Universal GFR determination based on two time points during plasma iohexol disappearance.

Authors:  Derek K S Ng; George J Schwartz; Lisa P Jacobson; Frank J Palella; Joseph B Margolick; Bradley A Warady; Susan L Furth; Alvaro Muñoz
Journal:  Kidney Int       Date:  2011-06-08       Impact factor: 10.612

Review 6.  Glomerular filtration rate: when to measure and in which patients?

Authors:  Rajiv Agarwal; Pierre Delanaye
Journal:  Nephrol Dial Transplant       Date:  2019-12-01       Impact factor: 5.992

7.  Performance of creatinine- or cystatin C-based equations to estimate glomerular filtration rate in sub-Saharan African populations.

Authors:  Justine B Bukabau; Eric Yayo; Appolinaire Gnionsahé; Dagui Monnet; Hans Pottel; Etienne Cavalier; Aliocha Nkodila; Jean Robert R Makulo; Vieux M Mokoli; François B Lepira; Nazaire M Nseka; Jean-Marie Krzesinski; Ernest K Sumaili; Pierre Delanaye
Journal:  Kidney Int       Date:  2019-03-12       Impact factor: 10.612

8.  Reassessment of a classical single injection 51Cr-EDTA clearance method for determination of renal function in children and adults. Part I: Analytically correct relationship between total and one-pool clearance.

Authors:  Lars Jødal; Jens Brøchner-Mortensen
Journal:  Scand J Clin Lab Invest       Date:  2009       Impact factor: 1.713

9.  Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 2: Why to measure glomerular filtration rate with iohexol?

Authors:  Pierre Delanaye; Toralf Melsom; Natalie Ebert; Sten-Erik Bäck; Christophe Mariat; Etienne Cavalier; Jonas Björk; Anders Christensson; Ulf Nyman; Esteban Porrini; Giuseppe Remuzzi; Piero Ruggenenti; Elke Schaeffner; Inga Soveri; Gunnar Sterner; Bjørn Odvar Eriksen; Flavio Gaspari
Journal:  Clin Kidney J       Date:  2016-09-09
  9 in total
  2 in total

1.  Comparison of Plasma Clearance With Early-Compartment Correction Equations and Urinary Clearance in High GFR Ranges.

Authors:  Pierre Delanaye; Emmanuelle Vidal-Petiot; Thomas Stehlé; Laurence Dubourg; François Gaillard; Gunnar Sterner; Christine A White; Sandrine Lemoine; Vincent Audard; Dominique Prié; Etienne Cavalier; Marie Courbebaisse; Hans Pottel; Martin Flamant
Journal:  Kidney Int Rep       Date:  2021-03-31

2.  51Cr-EDTA plasma clearance in children: One, two, or multiple samples?

Authors:  Hans Pottel; Karolien Goffin; Liesbeth De Waele; Elena Levtchenko; Pierre Delanaye
Journal:  Medicine (Baltimore)       Date:  2022-01-21       Impact factor: 1.889

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.