Literature DB >> 14573371

Design and responses of Butterworth and critically damped digital filters.

D Gordon E Robertson1, James J Dowling.   

Abstract

For many years the Butterworth lowpass filter has been used to smooth many kinds of biomechanical data, despite the fact that it is underdamped and therefore overshoots and/or undershoots data during rapid transitions. A comparison of the conventional Butterworth filter with a critically damped filter shows that the critically damped filter not only removes the undershooting and overshooting, but has a superior rise time during rapid transitions. While analog filters always create phase distortion, both the critically damped and Butterworth filters can be modified to become zero-lag filters when the data are processed in both the forward and reverse directions. In such cases little improvement is realized by applying multiple passes. The Butterworth filter has superior 'roll-off' (attenuation of noise above the cutoff frequency) than the critically damped filter, but by increasing the number of passes of the critically damped filter the same 'roll-off' can be achieved. In summary, the critically damped filter was shown to have superior performance in the time domain than the Butterworth filter, but for data that need to be double differentiated (e.g. displacement data) the Butterworth filter may still be the better choice.

Mesh:

Year:  2003        PMID: 14573371     DOI: 10.1016/s1050-6411(03)00080-4

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  40 in total

1.  Full-Body Musculoskeletal Model for Muscle-Driven Simulation of Human Gait.

Authors:  Apoorva Rajagopal; Christopher L Dembia; Matthew S DeMers; Denny D Delp; Jennifer L Hicks; Scott L Delp
Journal:  IEEE Trans Biomed Eng       Date:  2016-07-07       Impact factor: 4.538

2.  Time course of neuro-mechanical changes underlying stretch-shortening cycle during intermittent exhaustive rebound exercise.

Authors:  Cédric Morio; Pascale Chavet; Philippe Androuet; Matthieu Foissac; Eric Berton; Caroline Nicol
Journal:  Eur J Appl Physiol       Date:  2011-02-19       Impact factor: 3.078

3.  Kinematic Accuracy in Tracking Total Wrist Arthroplasty with Biplane Videoradiography using a CT-generated Model.

Authors:  Bardiya Akhbari; Amy Morton; Douglas Moore; Arnold-Peter C Weiss; Scott W Wolfe; Joseph Crisco
Journal:  J Biomech Eng       Date:  2019-02-07       Impact factor: 2.097

4.  How muscle fiber lengths and velocities affect muscle force generation as humans walk and run at different speeds.

Authors:  Edith M Arnold; Samuel R Hamner; Ajay Seth; Matthew Millard; Scott L Delp
Journal:  J Exp Biol       Date:  2013-03-07       Impact factor: 3.312

5.  Soft tissue artifact causes underestimation of hip joint kinematics and kinetics in a rigid-body musculoskeletal model.

Authors:  Niccolo M Fiorentino; Penny R Atkins; Michael J Kutschke; K Bo Foreman; Andrew E Anderson
Journal:  J Biomech       Date:  2020-06-13       Impact factor: 2.712

Review 6.  A brief review of strength and ballistic assessment methodologies in sport.

Authors:  Daniel Travis McMaster; Nicholas Gill; John Cronin; Michael McGuigan
Journal:  Sports Med       Date:  2014-05       Impact factor: 11.136

7.  Position of the non-stance leg during the single leg squat affects females and males differently.

Authors:  Anne Khuu; Cara L Lewis
Journal:  Hum Mov Sci       Date:  2019-08-21       Impact factor: 2.161

8.  Upper body 3-dimensional kinematics during gait in psychotic patients: a pilot-study.

Authors:  A Stensdotter; N Pedersen; A Wanvik; F Öhberg; J C Fløvig; E A Fors
Journal:  Exp Brain Res       Date:  2012-07-22       Impact factor: 1.972

9.  Changes in Gait with Anteriorly Added Mass: A Pregnancy Simulation Study.

Authors:  Maureen I Ogamba; Kari L Loverro; Natalie M Laudicina; Simone V Gill; Cara L Lewis
Journal:  J Appl Biomech       Date:  2016-03-08       Impact factor: 1.833

10.  Muscle contributions to fore-aft and vertical body mass center accelerations over a range of running speeds.

Authors:  Samuel R Hamner; Scott L Delp
Journal:  J Biomech       Date:  2012-12-11       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.