Literature DB >> 326304

Astigmatism in cataract surgery.

M H Luntz, D G Livingston.   

Abstract

We report on our investigation into astigmatism in 40 eyes following a corneal cataract incision closed with a continuous 10/0 nylon monofilament suture (Ethilon). Immediately after surgery there was astigmatism caused by the nylon suture (suture-induced astigmatism), its severity depending on the tightness of the suture. It ranged from 1 to 10-5 dioptres, the mean value 4-09 dioptres with a standard deviation of +/-2-5. Removing the nylon suture eliminated this astigmatism and within a few weeks the corneal astigmatism correction in 48% of eyes returned to the preoperative level. In 80% of eyes the difference between the final postoperative corneal astigmatism (4 months after removing the continuous suture) and the preoperative astigmatism was 0-75 dioptres or less and the maximum change was 1-5 dioptres. In 40% of eyes the axis of the cylinder changed from a horizontal to an oblique axis but did not change from a with- to against-the-rule axis. The degree of astigmatism remained constant while the suture was in place and in 50% of eyes was equal to or less than 3 dioptres. The mean of the spherical equivalents was 11-31 dioptres with a standard deviation of +/-1-25. A spectacle correction 14 days after operation prescribed either as the mean spherical equivalent (11-50 dioptres) or according to the patient's refraction will give satisfactory vision until the suture is removed 4 months after operation. The degree of astigmatism following a corneal section and continuous nylon suture compares very favourably with astigmatism following other suturing techniques for cataract.

Entities:  

Mesh:

Year:  1977        PMID: 326304      PMCID: PMC1042969          DOI: 10.1136/bjo.61.5.360

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  5 in total

1.  Visual outcome of the first 500 cataract extractions done in the field; Jimma, Ethiopia.

Authors:  N Zerihun
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

2.  Corneal astigmatism following cataract extraction.

Authors:  M S Wishart; P K Wishart; Z J Gregor
Journal:  Br J Ophthalmol       Date:  1986-11       Impact factor: 4.638

3.  Factors influencing the accuracy of the SRK formula in the intraocular less power calculation.

Authors:  C Kalogeropoulos; M Aspiotis; M Stefaniotou; K Psilas
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

4.  Astigmatism following cataract surgery: comparison of a scleral and a corneal incision in a mixed group of patients with and without glaucoma.

Authors:  T S Lim; F P Gunning; E L Greve
Journal:  Int Ophthalmol       Date:  1992-05       Impact factor: 2.031

Review 5.  Myopic astigmatism a substitute for accommodation in pseudophakia.

Authors:  C Huber
Journal:  Doc Ophthalmol       Date:  1981-12-16       Impact factor: 2.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.