Literature DB >> 32630329

Indoor Air Quality in Passivhaus Dwellings: A Literature Review.

Alejandro Moreno-Rangel1, Tim Sharpe2, Gráinne McGill2, Filbert Musau3.   

Abstract

Indoor air quality (IAQ) is a critical consideration in airtight buildings that depend on mechanical ventilation, such as those constructed to the Passivhaus standard. While previous reviews of IAQ on Passivhaus-certified buildings foccused on offices, this study examines residential buildings. A summary of data collection methods and pollutant concentrations is presented, followed by a critical discussion of the impact of Passivhaus design strategies on IAQ. This review indicates that IAQ in Passivhaus-certified dwellings is generally better than in conventional homes, but both occupant behaviour and pollution from outdoor sources play a significant role in indoor concentrations. Moreover, there are differences in data collection and reporting methods. Many of the available studies depend on short-term IAQ monitoring of less than two weeks, making it difficult to determine the longer impact of housing design on IAQ and occupants' well-being. There is also a lack of studies from non-European countries. Future research should focus on investigating associations between IAQ and Passivhaus design strategies in hot and humid climates, where evidence is particularly lacking. Further effort is also required to investigate potential links between occupant's perception of IAQ and physical exposure to indoor pollution. Finally, the lack of homogeneous monitoring and reporting methods for IAQ studies needs to be addressed.

Entities:  

Keywords:  healthy homes; indoor air quality (IAQ), Passivhaus; indoor environment; literature review; thermal comfort

Year:  2020        PMID: 32630329     DOI: 10.3390/ijerph17134749

Source DB:  PubMed          Journal:  Int J Environ Res Public Health        ISSN: 1660-4601            Impact factor:   3.390


  4 in total

1.  Distribution Characteristics of Indoor PM2.5 Concentration Based on the Water Type and Humidification Method.

Authors:  Seonghyun Park; Janghoo Seo; Sunwoo Lee
Journal:  Int J Environ Res Public Health       Date:  2020-11-20       Impact factor: 3.390

2.  A Basic Study on the Performance Evaluation of a Movable Light Shelf with a Rolling Reflector That Can Change Reflectivity to Improve the Visual Environment.

Authors:  Heangwoo Lee
Journal:  Int J Environ Res Public Health       Date:  2020-11-11       Impact factor: 3.390

3.  Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates.

Authors:  Mohammad Arar; Chuloh Jung
Journal:  Int J Environ Res Public Health       Date:  2021-11-18       Impact factor: 3.390

Review 4.  Latest Trends in Pollutant Accumulations at Threatening Levels in Energy-Efficient Residential Buildings with and without Mechanical Ventilation: A Review.

Authors:  Hélène Niculita-Hirzel
Journal:  Int J Environ Res Public Health       Date:  2022-03-16       Impact factor: 3.390

  4 in total