Literature DB >> 32630294

Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading: A Three-Dimensional Finite Element Analysis.

Hélder Oliveira1, Aritza Brizuela Velasco2, José-Vicente Ríos-Santos3, Fernando Sánchez Lasheras4, Bernardo Ferreira Lemos1, Francisco Javier Gil5, Alexandrine Carvalho1, Mariano Herrero-Climent6.   

Abstract

Implant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and strain distribution to the implants and surrounding bone. Three implant designs with the same length and diameter were used. The three-dimensional geometry of the bone was simulated with a cortical bone of three different thicknesses and two medullar bone densities: low density (150 Hounsfield units) and high density (850 Hounsfield units). A 30° oblique load of 150 N was applied to the implant restoration. Displacement and stress (von Mises) results were obtained for bone and dental implants. The strain and stress distributions to the bone were higher for the tissue-level implant for all types of bone. The maximum principal strain and stress decreased with an increase in cortical bone thickness for both cancellous bone densities. The distribution of the load was concentrated at the coronal portion of the bone and implants. All implants showed a good distribution of forces for non-axial loads, with higher forces concentrated at the crestal region of the bone-implant interface. Decrease in medullar bone density negatively affects the strain and stress produced by the implants.

Entities:  

Keywords:  bone quality; dental implants; design; finite element analysis; strain distribution; stress distribution

Year:  2020        PMID: 32630294     DOI: 10.3390/ijerph17134738

Source DB:  PubMed          Journal:  Int J Environ Res Public Health        ISSN: 1660-4601            Impact factor:   3.390


  7 in total

1.  Biomechanical evaluations of the long-term stability of dental implant using finite element modeling method: a systematic review.

Authors:  Seyed Aref Hosseini-Faradonbeh; Hamid Reza Katoozian
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

2.  Biomechanical Comparison of Six Different Root-Analog Implants and the Conventional Morse Taper Implant by Finite Element Analysis.

Authors:  Jia-Qing Wang; Yuan Zhang; Min Pang; Yue-Qiu Wang; Jun Yuan; Hui Peng; Wen Zhang; Lu Dai; Hong-Wei Li
Journal:  Front Genet       Date:  2022-06-13       Impact factor: 4.772

3.  Influence of Connection Type and Platform Diameter on Titanium Dental Implants Fatigue: Non-Axial Loading Cyclic Test Analysis.

Authors:  Ana I Nicolas-Silvente; Eugenio Velasco-Ortega; Ivan Ortiz-Garcia; Alvaro Jimenez-Guerra; Loreto Monsalve-Guil; Raul Ayuso-Montero; Javier Gil; Jose Lopez-Lopez
Journal:  Int J Environ Res Public Health       Date:  2020-12-02       Impact factor: 3.390

4.  One Abutment One Time: A Multicenter, Prospective, Controlled, Randomized Study.

Authors:  José Vicente Ríos-Santos; Gregorio Tello-González; Pedro Lázaro-Calvo; Francisco Javier Gil Mur; Blanca Ríos-Carrasco; Ana Fernández-Palacín; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2020-12-17       Impact factor: 3.390

5.  Consequences of Peri-Implant Bone Loss in the Occlusal Load Transfer to the Supporting Bone in terms of Magnitude of Stress, Strain, and Stress Distribution: A Finite Element Analysis.

Authors:  Esteban Pérez-Pevida; David Chávarri-Prado; Markel Diéguez-Pereira; Alejandro Estrada-Martínez; Oier Montalbán-Vadillo; Antonio Jiménez-Garrudo
Journal:  Biomed Res Int       Date:  2021-09-01       Impact factor: 3.411

6.  Stress Distribution Analysis of Threaded Implants for Digital Dentistry.

Authors:  Seokho Ahn; Jaesung Kim; Seok Chan Jeong; Myungil Kim; Cheolyoung Kim; Dongki Park
Journal:  Int J Environ Res Public Health       Date:  2022-10-04       Impact factor: 4.614

7.  Biomechanical Properties of Bone and Mucosa for Design and Application of Dental Implants.

Authors:  Michael Gasik; France Lambert; Miljana Bacevic
Journal:  Materials (Basel)       Date:  2021-05-26       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.