Literature DB >> 32623499

Feasibility and safety of magnetic-end double-J ureteral stent insertion and removal in children.

Marc Chalhoub1,2, Jules Kohaut1,2, Nicolas Vinit1,2, Nathalie Botto1, Yves Aigrain1,2, Yves Héloury1,2, Henri Lottmann1, Thomas Blanc3,4,5.   

Abstract

PURPOSE: The need for surgical removal of a double-J ureteral stent (DJUS) is considered one of its disadvantages. Apart from increased cost, repeated exposure to general anesthesia is a concern in children. Alternative techniques have been described, all failing to become integrated into mainstream practice. Stents with a distal magnetic end, although introduced in the early 1980s, have only recently gained acceptance. We report the feasibility and safety of insertion and removal of a magnetic-end double-J ureteral stent (MEDJUS) in a pediatric population.
MATERIALS AND METHODS: We retrospectively analyzed the use of the Magnetic Black-Star Urotech® MEDJUS between 11/2016 and 12/2019 in children. Stents were removed in the outpatient clinic using a transurethral catheter with a magnetic tip.
RESULTS: MEDJUS insertion was attempted in 100 patients (65 boys). Mean age was 7.8 years (0.5-18). The stent was placed in an antegrade procedure (n = 47), by a retrograde route (n = 10), and during open surgery (n = 43). Stent insertion was successful in 84 cases (84%). All 16 failures occurred during the antegrade approach in laparoscopic pyeloplasty, with inability to push the stent and its magnet through the ureterovesical junction in 14. Magnetic removal was attempted in 83 patients, successful in 81 (98%). There was no added morbidity with the MEDJUS.
CONCLUSIONS: The use of MEDJUS is a safe and effective strategy that obviates the need for additional general anesthesia in children. Its insertion is similar to that with regular DJUS, and its easy and less time-consuming removal benefits both the patient and the hospital and validates its clinical use.

Entities:  

Keywords:  Children; Magnetic stent; Removal; Ureteral stent; Urology

Year:  2020        PMID: 32623499     DOI: 10.1007/s00345-020-03339-0

Source DB:  PubMed          Journal:  World J Urol        ISSN: 0724-4983            Impact factor:   4.226


  19 in total

1.  Shortened pull-string simplifies office-based ureteral stent removal.

Authors:  J Stephen Jones
Journal:  Urology       Date:  2002-12       Impact factor: 2.649

2.  First clinical evaluation of a new single-use flexible cystoscope dedicated to double-J stent removal (Isiris™): a European prospective multicenter study.

Authors:  Steeve Doizi; Guido Kamphuis; Guido Giusti; J L Palmero; J M Patterson; Silvia Proietti; Michael Straub; Jean de la Rosette; Olivier Traxer
Journal:  World J Urol       Date:  2016-12-17       Impact factor: 4.226

Review 3.  Evolution of the Ureteral Stent: The Pivotal Role of the Gibbons Ureteral Catheter.

Authors:  Ryan P Donahue; Andrew W Stamm; Robert P Gibbons; Christopher R Porter; Kathleen C Kobashi; John M Corman; Una J Lee
Journal:  Urology       Date:  2018-03-12       Impact factor: 2.649

4.  Evaluation of a New Design of Antireflux-biodegradable Ureteral Stent in Animal Model.

Authors:  Federico Soria; Esther Morcillo; Alvaro Serrano; Alberto Budia; Inmaculada Fernández; Tomás Fernández-Aparicio; Francisco M Sanchez-Margallo
Journal:  Urology       Date:  2018-02-19       Impact factor: 2.649

5.  Magnetic Ureteral Stent Removal Without Cystoscopy: A Randomized Controlled Trial.

Authors:  Marie-Claire Rassweiler; Maurice-Stephan Michel; Manuel Ritter; Patrick Honeck
Journal:  J Endourol       Date:  2017-06-07       Impact factor: 2.942

6.  A cheap minimally painful and widely usable alternative for retrieving ureteral stents.

Authors:  Haluk Söylemez; Ahmet Ali Sancaktutar; Yaşar Bozkurt; Murat Atar; Necmettin Penbegül; Kadir Yildirim
Journal:  Urol Int       Date:  2011-08-03       Impact factor: 2.089

Review 7.  Does general anesthesia affect neurodevelopment in infants and children?

Authors:  Mary Ellen McCann; Sulpicio G Soriano
Journal:  BMJ       Date:  2019-12-09

8.  Experience with new double J ureteral catheter stent.

Authors:  R P Finney
Journal:  J Urol       Date:  1978-12       Impact factor: 7.450

9.  Ureteric stent placement with extraction string: no strings attached?

Authors:  Nathan A Bockholt; Trevor T Wild; Amit Gupta; Chad R Tracy
Journal:  BJU Int       Date:  2012-05-11       Impact factor: 5.588

10.  Ureteral stent retrieval using the crochet hook technique in females.

Authors:  Takashi Kawahara; Hiroki Ito; Hideyuki Terao; Takuya Yamagishi; Takehiko Ogawa; Hiroji Uemura; Yoshinobu Kubota; Junichi Matsuzaki
Journal:  PLoS One       Date:  2012-01-03       Impact factor: 3.240

View more
  1 in total

1.  The Function Improved of the Newly Designed Magnetic-End Ureteric Stenting Retrieval Device: A Clinical Prospective Randomized and Control Trial in a Multicenter Study.

Authors:  Shaohua Zeng; Bo Liu; Hu Hu; Jian Shi; Ping Qian; Xiaoping Zhang; Kexue Peng; Sixing Yang; Zheng Huang; Tiejun Pan
Journal:  Contrast Media Mol Imaging       Date:  2022-04-18       Impact factor: 3.009

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.