Deep throat saliva as an alternative diagnostic specimen type for the detection of SARS-CoV-2.

Eddie Chi-Man Leung1, Viola Chi-Ying Chow1, May Kin-Ping Lee1, Raymond Wai-Man Lai1.   

Abstract

Nasopharyngeal swabs (NPS) are widely accepted as specimens for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the current pandemic of coronavirus disease 2019. However, the collection procedures for NPS specimens causes sneezing and coughing in most patients, which generate droplets or aerosol particles that are hazardous to the healthcare workers collecting these specimens. In this study, 95 patient-matched paired deep throat saliva (DTS) and NPS specimens from 62 patients were analyzed. Samples were tested for SARS-CoV-2 by reverse-transcription polymerase chain reaction (RT-PCR). The rates of detection for DTS (53.7%) and NPS (47.4%) samples were comparable (P = .13). It is important to note that the patients should be clearly instructed or supervised during DTS collection. In conclusion, SARS-CoV-2 detection by RT-PCR was equivalent in DTS and NPS specimens.
© 2020 Wiley Periodicals LLC.

Entities:  

Keywords:  COVID-19; RT-PCR; SARS-CoV-2; deep throat saliva

Mesh:

Year:  2020        PMID: 32621616      PMCID: PMC7361401          DOI: 10.1002/jmv.26258

Source DB:  PubMed          Journal:  J Med Virol        ISSN: 0146-6615            Impact factor:   20.693


INTRODUCTION

Coronavirus disease 2019 (COVID‐19) refers to a cluster of viral pneumonia cases that were first identified in December 2019 in Wuhan, a city in the Hubei Province of China. A novel coronavirus, currently known as severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2), is the causative agent of COVID‐19. Subsequently, COVID‐19 has spread across the world to 214 countries in Asia, North America, South America, Europe, Australia and Africa, affecting 3 267 184 people, including 229 971 deaths thus far. Health authorities worldwide are seeking effective public‐health interventions for fighting against this pandemic. One way to effectively manage the COVID‐19 pandemic is to enhance laboratory testing and obtaining the appropriate sample type is a key component of accurate diagnostic testing. Real‐time reverse transcription‐polymerase chain reaction (RT‐PCR) of nasopharyngeal and lower respiratory specimens is widely used to detect SARS‐CoV‐2. , However, collecting nasopharyngeal specimens causes patient discomfort and may trigger sneezing and coughing, which could generate droplets or aerosol particles that are hazardous to the healthcare workers collecting the samples. Therefore, saliva has been proposed as an alternative specimen type for the diagnosis of COVID‐19. As saliva could be collected by the patients themselves, it could reduce the nosocomial transmission risk to healthcare workers. , Furthermore, the use of saliva could reduce the demand for swabs, which is currently in short supply. The performance of saliva as a diagnostic specimen type for the detection of respiratory viruses and SARS‐CoV‐2 has been previously studied. , However, these studies lacked detail on the mode of specimen collection, in particular, whether deep throat (posterior oropharyngeal) saliva and not oral saliva, should be recommended for use as a type of diagnostic specimen. This study aimed to assess the comparability of deep throat saliva (DTS) samples to nasopharyngeal swab (NPS) samples as an alternative specimen type for the detection of SARS‐CoV‐2 by RT‐PCR.

Study design

A retrospective study was conducted from February to March 2020, analyzing patient‐matched paired specimens of DTS and NPS collected on the same day from patients admitted to the Prince of Wales Hospital in Hong Kong. To collect DTS samples, patients were provided clear instructions to collect saliva from the deep throat (posterior oropharyngeal) in a sterile sputum container. In‐house prepared viral transport medium (2 mL) was added in the laboratory for sample processing. NPS samples were collected by the nursing staff using flocked swabs in a container with 3 ml viral transport medium. Collected specimens were sent to the laboratory immediately for SARS‐CoV‐2 RT‐PCR testing.

Reverse transcription‐polymerase chain reaction assay

An RT‐PCR assay using the lightMix Modular SARS‐CoV (COVID19) E‐gene detection kit (TIB Molbiol, Berlin, Germany), which target a 78 base pair fragment from a conserved region in the E gene of SARS CoV‐1, SARS CoV‐2, and the bat‐associated SARS‐related virus (Sarbecovirus), was used as a screening assay. Briefly, nucleic acid extraction was performed using the MagMAX (Applied Biosystems, Foster city) and a viral RNA isolation kit (Applied Biosystems), and 50 µL of viral RNA was obtained from every 200 µL sample. A 20 µL reaction mix containing 5 µL of 4X TaqMan fast (Applied Biosystems), 0.5 µL primer‐probe mix, 4.5 µL Nuclease‐free water, and 10 µL nucleic acid was prepared. RT‐PCR was conducted using the ABI 7900 real‐time PCR system (Applied Biosystems) under the following conditions: 5 minutes at 55°C, 20 seconds at 95°C, 40 cycles of 3 seconds at 95°C, and 30 seconds at 60°C. The samples that tested positive for SARS‐CoV‐2 were sent to the Public Health Laboratory Service Branch in Hong Kong for confirmation, where they used a different RT‐PCR assay that targeted a SARS‐CoV‐2 specific RdRp gene region.

Data analysis

The SARS‐CoV‐2 detection rates for DTS and NPS were compared by Pearson's χ 2 test. Analysis of correlation agreement methods, such as percent agreement and κ statistic, were used to determine the comparability of the two sampling methods. Statistical analyses were performed using the MedCalc statistical software version 16.4.3 (Ostend, Belgium).

RESULTS

This study analyzed 95 patient‐matched paired samples from 62 patients including 29 confirmed patients with COVID‐19 and 33 COVID‐19 negative patients, of which 26 were males aged 19 to 85 years (mean age: 42.0 ± 17.1 years). The comparison of clinical performance between DTS and NPS samples, based on the RT‐PCR detection of SARS‐CoV‐2, are shown in Table 1. There were no statistical differences between the detection rates of DTS and NPS (P > .05). With regard to the correlation, the overall agreement between the two sampling methods was 78.9% and the kappa value was 0.58, indicating moderate agreement between these two sample types.
Table 1

Clinical performance comparison between DTS and NPS for detecting SARS‐CoV‐2

Paired samples (n = 95)
DTSa NPSb
No. of RT‐PCR positive sample (%)51 (53.7)45 (47.4)
No. of RT‐PCR negative sample (%)44 (46.3)50 (52.6)
Overall agreement (95% CIc)78.9% (69.1%‐86.4%)
Kappa (95% CI)0.58 (0.42‐0.74)
P d 0.13

Abbreviations: CI, confidence interval; DTS, deep throat saliva; NPS, nasopharyngeal swabs; RT‐PCR, reverse transcription‐polymerase chain reaction.

Deep throat saliva.

Nasopharyngeal swab.

Confidence internal.

P value from Pearson's χ 2 comparison.

Clinical performance comparison between DTS and NPS for detecting SARS‐CoV‐2 Abbreviations: CI, confidence interval; DTS, deep throat saliva; NPS, nasopharyngeal swabs; RT‐PCR, reverse transcription‐polymerase chain reaction. Deep throat saliva. Nasopharyngeal swab. Confidence internal. P value from Pearson's χ 2 comparison. There were 75 concordant samples and 20 discordant samples between the two specimen types evaluated. The assessment of SARS‐CoV‐2 RT‐PCR results of DTS and NPS samples from confirmed patients with COVID‐19 are listed in Table 2. The 20 discordant samples pair were collected from 12 confirmed patients with COVID‐19, of which 13 DTS samples that showed positive results had corresponding NPS samples that were negative. Seven NPS samples that showed positive results had corresponding negative DTS samples. When evaluating the cycle threshold (C t) values obtained from the positive results, the discordant pairs of negative NPS/positive DTS samples had positive C t values ranging from 33.7 to 37.9, whereas the discordant pairs of negative DTS/positive NPS samples had values that ranged from 23.9 to 35.9. In general, DTS samples had a higher positive detection rate than NPS samples, although there were no statistically significant differences between the two sampling methods (P > .05). All negative samples from the discordant pairs could be considered as low viral load positive samples, except sample 70 from patient AY, which exhibited negative DTS and positive NPS results (C t value 23.9).
Table 2

The assessment of SARS‐CoV‐2 RT‐PCR results of NPS and DTS samples pairs from 29 confirmed patients with COVID‐19 (n = 61)

PatientSample pairSARS‐CoV‐2 RT‐PCR (C t a value)Assessment
NPSb DTSc
AE20P (21.3)P (25.4)Concordant
21P (25.9)P (31.3)Concordant
22P (29.3)P (33.2)Concordant
23P (32.4)P (33.0)Concordant
24P (33.3)P (34.0)Concordant
25N (0)P (36.7)Discordant
AB8P (22.3)P (19.9)Concordant
9P (28.8)P (24.6)Concordant
10P (28.4)P (27.7)Concordant
11P (27.7)P (25.2)Concordant
12P (33.1)N (0)Discordant
13N (0)P (35.8)Discordant
AJ34P (29.6)P (23.5)Concordant
35N (0)P (36.4)Discordant
36N (0)P (36.0)Discordant
37N (0)N (0)Concordant
BC77P (27.6)P (31.5)Concordant
78P (34.6)N (0)Discordant
79N (0)P (36.1)Discordant
80N (0)P (37.9)Discordant
AN45P (35.6)P (32.4)Concordant
46N (0)P (35.3)Discordant
47P (33.9)N (0)Discordant
BB75N (0)P (33.7)Discordant
76P (34.5)N (0)Discordant
AY70P (23.9)N (0)Discordant
71P (30.6)N (0)Discordant
AV59N (0)P (35.4)Discordant
60N (0)P (36.0)Discordant
BA73P (21.2)P (30.8)Concordant
74P (35.9)N (0)Discordant
AC14N (0)P (37.6)Discordant
AO48N (0)P (33.8)Discordant
AZ72N (0)P (35.6)Discordant
AI30P (32.8)P (34.5)Concordant
31P (36.4)P (32.1)Concordant
32N (0)N (0)Concordant
33P (37.4)P (33.5)Concordant
BH90P (22.1)P (27.9)Concordant
91P (28.4)P (32.2)Concordant
92P (33.9)P (35.4)Concordant
AX67P (22.7)P (27.0)Concordant
68P (31.7)P (30.1)Concordant
AW65P (19.8)P (32.2)Concordant
66N (0)N (0)Concordant
AP51P (19.7)P (22.3)Concordant
52P (25.7)P (25.7)Concordant
AR54P (17.4)P (20.0)Concordant
55P (29.6)P (32.2)Concordant
BE82P (32.6)P (32.5)Concordant
83P (34.5)P (35.9)Concordant
AH28P (24.1)P (22.6)Concordant
AS56P (18.2)P (22.3)Concordant
AT57P (23.9)P (21.2)Concordant
AU58P (34.3)P (34.0)Concordant
AM42P (27.9)P (30.2)Concordant
AF26P (17.0)P (21.3)Concordant
AA1P (32.0)P (25.9)Concordant
BG89P (19.6)P (22.7)Concordant
AQ53P (26.5)P (30.6)Concordant
BF84P (25.2)P (31.0)Concordant

Abbreviations: COVID‐19, coronavirus disease 2019; DTS, deep throat saliva; NPS, Nasopharyngeal swabs; RT‐PCR, reverse transcription‐polymerase chain reaction; SARS‐CoV2, severe acute respiratory syndrome coronavirus 2.

Cycle threshold.

Nasopharyngeal swab.

Deep throat saliva.

The assessment of SARS‐CoV‐2 RT‐PCR results of NPS and DTS samples pairs from 29 confirmed patients with COVID‐19 (n = 61) Abbreviations: COVID‐19, coronavirus disease 2019; DTS, deep throat saliva; NPS, Nasopharyngeal swabs; RT‐PCR, reverse transcription‐polymerase chain reaction; SARS‐CoV2, severe acute respiratory syndrome coronavirus 2. Cycle threshold. Nasopharyngeal swab. Deep throat saliva.

DISCUSSION

Nasopharyngeal specimens, either from nasopharyngeal aspirates (NPA) or NPS, are the recommended specimen type for the detection of respiratory viruses. The NPS is also the most common validated specimen type for a majority of the commercially available respiratory virus detection kits. Thus, NPA or NPS is also the recommended specimen type for SARS‐CoV‐2 detection. Given the invasive nature of the procedures used to obtain NPA, NPS specimens were the specimen of choice for SARS‐CoV‐2 detection. The collection of NPS, although less invasive than NPA, may cause patients to cough, thus increasing the risk to healthcare workers. To combat the COVID‐19 pandemic, it is crucial to increase laboratory testing for SARS‐CoV‐2. However, dramatically increasing NPS collection would increase the nosocomial transmission risk to healthcare workers who undertake the specimen collection. In this study, the potential of patient self‐collected DTS as an alternative specimen type for the detection of SARS‐CoV‐2 was assessed. This study showed that the overall detection rate for SARS‐CoV‐2 from DTS was comparable to that from NPS samples. The detection rate of DTS samples (53.7%) was even higher than NPS samples (47.4), although the difference was not statistically significant (P > .05). This finding is especially critical at the moment, because there is a demand for alternative diagnostic specimen, such as DTS, for SARS‐CoV‐2 detection. DTS specimens can be easily provided by the patient and do not require healthcare workers for their collection. Furthermore, because of the sudden increase in the number of laboratory tests, DTS provides an alternative that could alleviate the global shortages for swabs and personal protective equipment. A total of 20 discordant paired samples from 12 confirmed patients with COVID‐19 were found in this study. By evaluating the C t value of these samples, all but one (sample 70: NPS positive C t value 23.9/negative DTS) had low viral loads (high C t value). The lone outlying pair may be explained by a discrepancy in the quality of the NPS and DTS samples, which differed in their collection methods, since the NPS samples were collected by trained healthcare personnel, while DTS samples were collected by the patients themselves. When the suitability of DTS for testing was evaluated, it was observed that the quality of samples could be dependent on the patient's understanding of the collection procedure for deep throat (posterior oropharyngeal) saliva. Thus a pre‐collection briefing and explanation of this procedure are very important. Based on past experience, clear instructions with color‐printed step‐by‐step procedures or video demonstration can help patients understand the collection procedures. In addition to clear patient instructions, it is also recommended that a nurse should be present to supervise during the collection process. According to reports, the Hong Kong health department has been using DTS for the detection of SARS‐CoV‐2 in asymptomatic returnees at the airport. By using DTS samples, mass screening could be implemented as the returnees are required to collect their own specimens and thus, could also prevent crowding at the sample collection centers. Currently, DTS is not a validated sample type for commercially available detection kits of SARS‐CoV‐2 or other respiratory viruses. To enhance the flexibility of laboratory testing strategies, vendors should include DTS as an alternative validated specimen type. There are several limitations to this study. First, this is a single‐center study. Second, the sample size was small and only 95 paired DTS and NPS samples were selected for comparison. Third, the DTS and NPS samples were not collected at the same time, but on the same day.

CONCLUSION

This study showed that the overall performance of DTS was equivalent to that of the NPS, as specimens used in the detection of SARS‐CoV‐2 by RT‐PCR assay.

CONFLICT OF INTERESTS

The authors declare that there are no conflict of interests.

AUTHOR CONTRIBTUONS

Dr. Eddie Leung carried out the experiments, performed the analysis and drafted the manuscript. Dr. Viola Chow and Dr. May Lee contributed to the interpretation of the results. Dr. Raymond Lai conceptualized and supervised the project. All authors discussed the results and contributed to the final manuscript.
  8 in total

1.  Saliva as a diagnostic specimen for testing respiratory virus by a point-of-care molecular assay: a diagnostic validity study.

Authors:  K K W To; C C Y Yip; C Y W Lai; C K H Wong; D T Y Ho; P K P Pang; A C K Ng; K-H Leung; R W S Poon; K-H Chan; V C C Cheng; I F N Hung; K-Y Yuen
Journal:  Clin Microbiol Infect       Date:  2018-06-12       Impact factor: 8.067

2.  Accuracy and Discomfort of Different Types of Intranasal Specimen Collection Methods for Molecular Influenza Testing in Emergency Department Patients.

Authors:  Bradley W Frazee; Amparo Rodríguez-Hoces de la Guardia; Harrison Alter; Carol G Chen; Eugenia L Fuentes; Alison K Holzer; Macarena Lolas; Debkishore Mitra; Jaspreet Vohra; Cornelia L Dekker
Journal:  Ann Emerg Med       Date:  2017-11-24       Impact factor: 5.721

3.  Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort study.

Authors:  Kelvin Kai-Wang To; Owen Tak-Yin Tsang; Wai-Shing Leung; Anthony Raymond Tam; Tak-Chiu Wu; David Christopher Lung; Cyril Chik-Yan Yip; Jian-Piao Cai; Jacky Man-Chun Chan; Thomas Shiu-Hong Chik; Daphne Pui-Ling Lau; Chris Yau-Chung Choi; Lin-Lei Chen; Wan-Mui Chan; Kwok-Hung Chan; Jonathan Daniel Ip; Anthony Chin-Ki Ng; Rosana Wing-Shan Poon; Cui-Ting Luo; Vincent Chi-Chung Cheng; Jasper Fuk-Woo Chan; Ivan Fan-Ngai Hung; Zhiwei Chen; Honglin Chen; Kwok-Yung Yuen
Journal:  Lancet Infect Dis       Date:  2020-03-23       Impact factor: 25.071

4.  SARS-CoV-2 Viral Load in Upper Respiratory Specimens of Infected Patients.

Authors:  Lirong Zou; Feng Ruan; Mingxing Huang; Lijun Liang; Huitao Huang; Zhongsi Hong; Jianxiang Yu; Min Kang; Yingchao Song; Jinyu Xia; Qianfang Guo; Tie Song; Jianfeng He; Hui-Ling Yen; Malik Peiris; Jie Wu
Journal:  N Engl J Med       Date:  2020-02-19       Impact factor: 91.245

5.  Deep throat saliva as an alternative diagnostic specimen type for the detection of SARS-CoV-2.

Authors:  Eddie Chi-Man Leung; Viola Chi-Ying Chow; May Kin-Ping Lee; Raymond Wai-Man Lai
Journal:  J Med Virol       Date:  2020-07-14       Impact factor: 20.693

6.  Consistent Detection of 2019 Novel Coronavirus in Saliva.

Authors:  Kelvin Kai-Wang To; Owen Tak-Yin Tsang; Cyril Chik-Yan Yip; Kwok-Hung Chan; Tak-Chiu Wu; Jacky Man-Chun Chan; Wai-Shing Leung; Thomas Shiu-Hong Chik; Chris Yau-Chung Choi; Darshana H Kandamby; David Christopher Lung; Anthony Raymond Tam; Rosana Wing-Shan Poon; Agnes Yim-Fong Fung; Ivan Fan-Ngai Hung; Vincent Chi-Chung Cheng; Jasper Fuk-Woo Chan; Kwok-Yung Yuen
Journal:  Clin Infect Dis       Date:  2020-07-28       Impact factor: 9.079

7.  Saliva is a reliable tool to detect SARS-CoV-2.

Authors:  Lorenzo Azzi; Giulio Carcano; Francesco Gianfagna; Paolo Grossi; Daniela Dalla Gasperina; Angelo Genoni; Mauro Fasano; Fausto Sessa; Lucia Tettamanti; Francesco Carinci; Vittorio Maurino; Agostino Rossi; Angelo Tagliabue; Andreina Baj
Journal:  J Infect       Date:  2020-04-14       Impact factor: 6.072

8.  Combination of RT-qPCR testing and clinical features for diagnosis of COVID-19 facilitates management of SARS-CoV-2 outbreak.

Authors:  Yishan Wang; Hanyujie Kang; Xuefeng Liu; Zhaohui Tong
Journal:  J Med Virol       Date:  2020-03-11       Impact factor: 2.327

  8 in total
  20 in total

1.  SARS-CoV-2 saliva testing using RT-PCR: a systematic review.

Authors:  Eyituoyo Okoturo; Mary Amure
Journal:  Int J Infect Dis       Date:  2022-05-13       Impact factor: 12.074

Review 2.  Science's Response to CoVID-19.

Authors:  Marcus J C Long; Yimon Aye
Journal:  ChemMedChem       Date:  2021-06-22       Impact factor: 3.540

Review 3.  Saliva as a diagnostic specimen for SARS-CoV-2 detection: A scoping review.

Authors:  Yifei Wang; Akshaya Upadhyay; Sangeeth Pillai; Parisa Khayambashi; Simon D Tran
Journal:  Oral Dis       Date:  2022-04-21       Impact factor: 4.068

4.  Evaluation on testing of deep throat saliva and lower respiratory tract specimens with Xpert Xpress SARS-CoV-2 assay.

Authors:  River Chun-Wai Wong; Ann Han Wong; Yolanda Iok-Ieng Ho; Eddie Chi-Man Leung; Raymond Wai-Man Lai
Journal:  J Clin Virol       Date:  2020-08-16       Impact factor: 3.168

5.  A Direct Comparison of Enhanced Saliva to Nasopharyngeal Swab for the Detection of SARS-CoV-2 in Symptomatic Patients.

Authors:  Gary W Procop; Nabin K Shrestha; Sherilynn Vogel; Kelly Van Sickle; Susan Harrington; Daniel D Rhoads; Brian P Rubin; Paul Terpeluk
Journal:  J Clin Microbiol       Date:  2020-10-21       Impact factor: 5.948

Review 6.  Laboratory testing for the diagnosis of COVID-19.

Authors:  Christopher K C Lai; Wilson Lam
Journal:  Biochem Biophys Res Commun       Date:  2020-10-28       Impact factor: 3.575

Review 7.  Saliva Exhibits High Sensitivity and Specificity for the Detection of SARS-COV-2.

Authors:  Ibrahim Warsi; Zohaib Khurshid; Hamda Shazam; Muhammad Farooq Umer; Eisha Imran; Muhammad Owais Khan; Paul Desmond Slowey; J Max Goodson
Journal:  Diseases       Date:  2021-05-20

8.  Deep throat saliva as an alternative diagnostic specimen type for the detection of SARS-CoV-2.

Authors:  Eddie Chi-Man Leung; Viola Chi-Ying Chow; May Kin-Ping Lee; Raymond Wai-Man Lai
Journal:  J Med Virol       Date:  2020-07-14       Impact factor: 20.693

9.  Performance evaluation of Panther Fusion SARS-CoV-2 assay for detection of SARS-CoV-2 from deep throat saliva, nasopharyngeal, and lower-respiratory-tract specimens.

Authors:  River Chun-Wai Wong; Ann Han Wong; Yolanda Iok-Ieng Ho; Eddie Chi-Man Leung; Raymond Wai-Man Lai
Journal:  J Med Virol       Date:  2020-10-08       Impact factor: 20.693

Review 10.  Salivary diagnostics of the novel coronavirus SARS-CoV-2 (COVID-19).

Authors:  Evangelia Michailidou; Athanasios Poulopoulos; Georgios Tzimagiorgis
Journal:  Oral Dis       Date:  2020-12-04       Impact factor: 4.068

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.