Literature DB >> 32608152

Anatomical assessment by cone beam computed tomography with the use of lateral cephalograms to analyse the vertical bone height of the anterior palate for orthodontic mini-implants.

Stephan Christian Möhlhenrich1,2, Kristian Kniha2, Florian Peters2, Sachin Chhatwani1, Andreas Prescher3, Frank Hölzle2, Ali Modabber2, Golamreza Danesh1.   

Abstract

OBJECTIVE: Lateral cephalograms (LC) should be usable to evaluate the vertical bone height of the anterior maxilla for planning the placement of orthodontic mini-implants (OMI). The purpose of this study is to determine the usability of LC for examining the real vertical dimension of the anterior palate. SETTING AND SAMPLE POPULATION: Lateral cephalograms and corresponding cone beam computed tomography (CBCT) scans were employed for examining 30 fresh cadaver heads. MATERIALS &
METHODS: The minimum (distance A) and maximum (distance B) vertical palatal bone heights on LCs at the level of first premolars were measured, whereas the corresponding measurements were taken via CBCTs on the median, and 2-, 4- and 6-mm paramedian planes. Additionally, the overall minimum vertical palatal height on CBCT was recorded.
RESULTS: Distance A and B on LC were about 8.3 ± 2.5 mm and 9.9 ± 2.5 mm, respectively. The median palatal height on CBCT was significantly higher than both measurements on LC (P < .01). Furthermore, the bone supply on the paramedian planes was similar or higher on CBCT compared to Distance A and similar or less compared to Distance B. The strongest correlation at the level of the premolars was found in the comparison of the maximum vertical palatal height via LC with the vertical palatal height on the median plane via CBCT (r = .84, 95% CI: 0.69-0.92, P < .001).
CONCLUSIONS: In order to make the best possible use of the vertical bone supply of the anterior palate and to avoid injuries to the nasal floor, Distance A should be taken into account for planning paramedian OMI placements and distance B for median OMI insertion.
© 2020 The Authors. Orthodontics & Craniofacial Research published by John Wiley & Sons Ltd.

Entities:  

Keywords:  anterior palate; cone beam computed tomography; lateral cephalogram; orthodontic mini-implant; vertical bone height

Year:  2020        PMID: 32608152     DOI: 10.1111/ocr.12406

Source DB:  PubMed          Journal:  Orthod Craniofac Res        ISSN: 1601-6335            Impact factor:   1.826


  1 in total

Review 1.  Two-dimensional radiographs versus cone-beam computed tomography in planning mini-implant placement: A systematic review.

Authors:  Gabriela-Franco-da Rosa Caetano; Mariana-Quirino-Silveira Soares; Luciana-Butini Oliveira; José-Luiz-Cintra Junqueira; Monikelly-do Carmo-Chagas Nascimento
Journal:  J Clin Exp Dent       Date:  2022-08-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.