Literature DB >> 32590273

Volumetric Absorptive Microsampling (VAMS) for assaying immunosuppressants from venous whole blood by LC-MS/MS using a novel atmospheric pressure ionization probe (UniSpray™).

Lucía Paniagua-González1, Carla Díaz-Louzao2, Elena Lendoiro3, Esteban Otero-Antón4, Carmen Cadarso-Suárez5, Manuel López-Rivadulla6, Angelines Cruz7, Ana de-Castro-Ríos8.   

Abstract

Therapeutic drug monitoring (TDM) of immunosuppressants (IMS) is crucial to prevent rejection or toxicity after solid organ transplantation. Microsampling techniques (sampling <50 μL of blood) can be a good alternative to conventional venous sampling for TDM, due to their numerous advantages, including its easy and low-invasive sampling, enabling self-collection, and cost-saving shipment and storage. Furthermore, volumetric absorptive microsampling (VAMS) enables the collection of precise and accurate blood volumes, overcoming the hematocrit (Hct) effect related to dried blood spots, while offering the same benefits. In this work, an LC-MS/MS method for the determination of the 5 most common IMS (mycophenolic acid -MPA-, tacrolimus -TAC-, sirolimus -SIR-, everolimus -EVE- and cyclosporin A -CsA-) in venous blood collected with Mitra™ VAMS devices was developed and validated, employing a novel LC-MS/MS interface, Unispray™. The method was fully validated including linearity, limits of detection (LOD) and quantification (LLOQ), accuracy, precision, selectivity, carry-over, matrix effect, recovery, impact of Hct on recovery and autosampler and short-/long-term stability, satisfying acceptance criteria in all cases. LLOQs were 0.5 ng/mL for TAC, SIR and EVE, 20 ng/mL for CsA and 75 ng/mL for MPA. No impact of the Hct (range: 0.2 to 0.62 L/L) on recovery was found for any analyte. All compounds were stable in VAMS for at least 8 months at -20 °C. In addition, as part of the VAMS analytical method validation, we performed for the first time a broad statistical study to compare liquid venous blood concentrations from patients under TAC (n = 53) and MPA (n = 20) treatment to those observed when the same specimens were absorbed into VAMS. Our results showed that venous blood VAMS concentrations were correlated to those found in the original liquid venous blood, proving that the VAMS material itself will not bias blood drug concentrations. Therefore, the present method could be applied to evaluate possible correlations between venous blood and capillary blood collected with VAMS.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Immunosuppressants; LC–MS/MS; Tacrolimus; Therapeutic drug monitoring; UniSpray; Volumetric Absorptive Microsampling

Mesh:

Substances:

Year:  2020        PMID: 32590273     DOI: 10.1016/j.jpba.2020.113422

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  4 in total

Review 1.  Metabolomics Research in Periodontal Disease by Mass Spectrometry.

Authors:  Sachio Tsuchida; Tomohiro Nakayama
Journal:  Molecules       Date:  2022-04-30       Impact factor: 4.927

2.  Validation of a Capillary Dry Blood Sample MITRA-Based Assay for the Quantitative Determination of Systemic Tacrolimus Concentrations in Transplant Recipients.

Authors:  Nasrullah Undre; Ian Dawson; Varuna Aluvihare; Nassim Kamar; Faouzi Saliba; Nicholas Torpey; Swapneel Anaokar; Gbenga Kazeem; Imran Hussain
Journal:  Ther Drug Monit       Date:  2021-06-01       Impact factor: 3.681

3.  Quantitation of Tacrolimus in Human Whole Blood Samples Using the MITRA Microsampling Device.

Authors:  Nasrullah Undre; Imran Hussain; John Meijer; Johannes Stanta; Gordon Swan; Ian Dawson
Journal:  Ther Drug Monit       Date:  2021-06-01       Impact factor: 3.681

4.  Cannabidiol Determination on Peripheral Capillary Blood Using a Microsampling Method and Ultra-High-Performance Liquid Chromatography Tandem Mass Spectrometry with On-Line Sample Preparation.

Authors:  Federica Pigliasco; Sebastiano Barco; Sara Dubois; Francesca Marchese; Pasquale Striano; Tommaso Lomonaco; Francesca Mattioli; Gino Tripodi; Giuliana Cangemi
Journal:  Molecules       Date:  2020-08-08       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.