Diagnostic accuracy of preoperative SARS-CoV-2 testing in a population with 2% disease prevalence
| SARS-CoV-2 | Healthy | Totals | |
|---|---|---|---|
| RT-PCR positive | 14 (TP) | 49 (FP) | 63 |
| RT-PCR negative | 6 (FN) | 931 (TN) | 937 |
| Totals | 20 | 980 | 1000 |
Sensitivity = 14/(14+6) = 0.70. Specificity = 931/(931+49) = 0.95
Positive predictive value = 14/(14+49) = 0.22
Negative predictive value = 931/(931+6) = 0.99
FN = false negative; FP = false positive; RT-PCR = reverse transcriptase polymerase chain reaction; SARS-CoV-2 = severe acute respiratory syndrome coronavirus 2; TN = true negative; TP = true positive
Précision diagnostique du dépistage préopératoire du SARS-CoV-2 dans une population avec une prévalence de 2 % de la maladie
| SARS-CoV-2 | Sains | Total | |
|---|---|---|---|
| RT-PCR positif | 14 (VP) | 49 (FP) | 63 |
| RT-PCR négatif | 6 (FN) | 931 (VN) | 937 |
| Total | 20 | 980 | 1000 |
Sensibilité = 14/(14+6) = 0,70. Spécificité = 931/(931+49) = 0,95
Valeur prédictive positive = 14/(14+49) = 0,22
Valeur prédictive négative = 931/(931+6) = 0,99
FN = faux négatif; FP = faux positif; RT-PCR = amplification par polymérase avec transcription inverse en temps réel; SARS-CoV-2 = syndrome respiratoire aigu sévère du coronavirus 2; VN = vrai négatif; VP = vrai positif