Concentrations tested for each drug, and the fluid ratios between the drug and Plasma-Lyte
| Drug | Assayed concentration | Drug to Plasma-Lyte volume ratio |
|---|---|---|
| Adrenaline | 250 μg/ml | 1:3 |
| Dobutamine | 2 mg/ml | 1:5.25 |
| Dopamine | 4 mg/ml | 1:9 |
| Furosemide | 1 mg/ml | 1:9 |
| Midazolam | 3 mg/ml | 3:2 |
| Milrinone | 200 μg/ml | 1:4 |
| Morphine | 1 mg/ml | 1:9 |
Overall compatibility of 8 frequently used infused therapeutic agents with 4 intravenous fluids
C indicates that the combination is suitable for central administration, P for peripheral administration and X that it is not compatible
Concentrations tested in relation to typical infusion concentrations and ‘Y-site’ concentrations used in children (10 kg) and adults and whether there is proven compatibility at these concentrations for Plasma-Lyte and Plasma-Lyte and 5% glucose admixtures
| Drug | Concentration (μg/ml) as tested | Adults | Children (10 kg) | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Standard infusion concentration (μg/ml) | Ratio of tested to infusion concentrations | Proven compatibility | Standard infusion concentration (μg/ml) | Ratio of tested to infusion concentrations | Proven compatibility | ||||
| Infusion concentrations | Y site concentration | Infusion concentrations | Y site concentration | ||||||
| 250 | 80 | 3.13:1 | ✓ | ✓ | 60 | 4.17:1 | ✓ | ✓ | |
| 2000 | 5000 | 1:2.5 | ✗ | ✓ | 6000 | 1:3 | ✗ | ✓ | |
| 4000 | Not used | 6000 | 1:1.5 | ✗ | ✓ | ||||
| 1000 | 1000 | 1:1 | ✓* | ✓* | 10,000 | 1:10 | ✗ | ✓* | |
| 3000 | 5000 | 1:1.6 | ✗ | ✗ | 400 | 7.5:1 | ✗ | ✗ | |
| 200 | 200 | 1:1 | ✓ | ✓ | 150 | 1.33:1 | ✓ | ✓ | |
| 1000 | 1000 | 1:1 | ✓ | ✓ | 200 | 5:1 | ✓ | ✓ | |
*Only proven compatible with Plasma-Lyte