Literature DB >> 32573807

Minimizing the echo time in diffusion imaging using spiral readouts and a head gradient system.

Bertram Jakob Wilm1, Franciszek Hennel1, Manuela Barbara Roesler1, Markus Weiger1, Klaas Paul Pruessmann1.   

Abstract

PURPOSE: Diffusion weighted imaging (DWI) is commonly limited by low signal-to-noise ratio (SNR) as well as motion artifacts. To address this limitation, a method that allows to maximize the achievable signal yield and increase the resolution in motion robust single-shot DWI is presented.
METHODS: DWI was performed on a 3T scanner equipped with a recently developed gradient insert (gradient strength: 200 mT/m, slew rate: 600 T/m/s). To further shorten the echo time, Stejskal-Tanner diffusion encoding with a single-shot spiral readout was implemented. To allow non-Cartesian image reconstruction using such strong and fast gradients, the characterization of eddy current and concomitant field effects was performed based on field-camera measurements.
RESULTS: An echo time of only 19 ms was achieved for a b-factor of 1000 s/mm2 . An in-plane resolution of 0.68 mm was encoded by a single-shot spiral readout of 40.5 ms using 3-fold undersampling. The resulting images did not suffer from off-resonance artifacts and T 2 ∗ blurring that are common to single-shot images acquired with regular gradient systems.
CONCLUSION: Spiral diffusion imaging using a head gradient system, together with an accurate characterization of the encoding process allows for a substantial reduction of the echo time, and improves the achievable resolution in motion-insensitive single-shot DWI.
© 2020 International Society for Magnetic Resonance in Medicine.

Mesh:

Year:  2020        PMID: 32573807     DOI: 10.1002/mrm.28346

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

Review 1.  Mapping the human connectome using diffusion MRI at 300 mT/m gradient strength: Methodological advances and scientific impact.

Authors:  Qiuyun Fan; Cornelius Eichner; Maryam Afzali; Lars Mueller; Chantal M W Tax; Mathias Davids; Mirsad Mahmutovic; Boris Keil; Berkin Bilgic; Kawin Setsompop; Hong-Hsi Lee; Qiyuan Tian; Chiara Maffei; Gabriel Ramos-Llordén; Aapo Nummenmaa; Thomas Witzel; Anastasia Yendiki; Yi-Qiao Song; Chu-Chung Huang; Ching-Po Lin; Nikolaus Weiskopf; Alfred Anwander; Derek K Jones; Bruce R Rosen; Lawrence L Wald; Susie Y Huang
Journal:  Neuroimage       Date:  2022-02-23       Impact factor: 7.400

2.  Distortion-free, high-isotropic-resolution diffusion MRI with gSlider BUDA-EPI and multicoil dynamic B0 shimming.

Authors:  Congyu Liao; Berkin Bilgic; Qiyuan Tian; Jason P Stockmann; Xiaozhi Cao; Qiuyun Fan; Siddharth Srinivasan Iyer; Fuyixue Wang; Chanon Ngamsombat; Wei-Ching Lo; Mary Kate Manhard; Susie Y Huang; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2021-03-10       Impact factor: 3.737

3.  MaxGIRF: Image reconstruction incorporating concomitant field and gradient impulse response function effects.

Authors:  Nam G Lee; Rajiv Ramasawmy; Yongwan Lim; Adrienne E Campbell-Washburn; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2022-04-21       Impact factor: 3.737

4.  Evaluating diffusion dispersion across an extended range of b-values and frequencies: Exploiting gap-filled OGSE shapes, strong gradients, and spiral readouts.

Authors:  Eric Seth Michael; Franciszek Hennel; Klaas Paul Pruessmann
Journal:  Magn Reson Med       Date:  2022-01-20       Impact factor: 3.737

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.