| Literature DB >> 32536683 |
Cendrella Assaf1, Philippe Abou Samra1, Paul Nahas1.
Abstract
BACKGROUND The purpose of this study is to evaluate and compare color stability of 3 resin based restorative materials when immersed into staining media at 0, 3, 30, 45, 60, and 75 days, and to assess the efficacy of surface polishing in reducing possible discoloration. MATERIAL AND METHODS Ninety composite discs were prepared in a custom-made mold (5 mm diameter and 2 mm thick) from 3 different light cured composites (Filtek™ Z250, Harmonize™, and G-aenial). Color differences of all specimens were measured by a spectrophotometer according to the CIE L*a*b* system. After baseline color measurements, 30 discs from each composite group were randomly divided into 3 subgroups of 10 specimens each. Subgroups (n=10) were immersed for 75 days into different staining solutions: coffee, tomato sauce, and distilled water (control). Solutions were changed every week and color measurements were repeated every 15 days. At day 75, color measurements of the specimens were performed before and after surface polishing with aluminum oxide discs. The experimental data were statistically evaluated using repeated measures one-way ANOVA test followed by Tukey's multiple pairwise comparison with a significance level of 5%. RESULTS Of the 3 composites, G-aenial reported the highest color change deviation when immersed into coffee (ΔE=8.674), and tomato sauce (ΔE=7.737) at day 75, followed by Harmonize that also exhibited a significant difference for coffee (ΔE=4.7) and tomato sauce (ΔE=3.8) when compared to distilled water. While Filtek™ Z250 did not show any significant difference between the 3 storage solutions (P>0.05). Only G-aenial had significant color change (P<0.05) after polishing with aluminum oxide discs for all tested samples, whereas Filtek™ Z250 and Harmonize presented no significant difference after surface polishing (P>0.05). CONCLUSIONS Under the tested experimental conditions, Filtek™ Z250, among the 3 resin-based composites, exhibited the highest color stability when subjected to coffee and tomato sauce as well. Whereas, G-aenial presented the highest color deviation when immersed in both staining media. Surface polishing effectively reduced coffee and tomato sauce discolorations for G-aenial's specimens and had no significant effect regarding Filtek™ Z250 and Harmonize.Entities:
Mesh:
Substances:
Year: 2020 PMID: 32536683 PMCID: PMC7316162 DOI: 10.12659/MSMBR.923279
Source DB: PubMed Journal: Med Sci Monit Basic Res ISSN: 2325-4394
Materials used in the study.
| Materials | Initial Shade | Description | Composition | Manufacturer |
|---|---|---|---|---|
| Filtek™ Z250 | A2 | Universal microhybrid | Silica, Zirconia, Bis-GMA, UDMA, Bis-EMA | 3M ESPE, Dental Products, St. Paul, MN, USA |
| Harmonize™ | A2 | nano-filled | Zirconia and silica nanoparticles, Bis-GMA, TEGDMA, Bis-EMA | Kerr Corporation, Orange, CA, USA |
| G-aenial | A2 | microhybrid | Pre-polymerized (Silica, Strontium, Lanthanoid) | GC Dental Products, Tokyo, Japan |
Mean (standard deviation) of color change value ΔE.
| Resin composite | Immersion period | Staining solution | |||
|---|---|---|---|---|---|
| Distilled water | Coffee | Tomato sauce | |||
| G-aenial | 3 Days | 1.499 (0.53) A | 4.383 (1.09) | 1.430 (0.73) B | 0.00010 |
| 30 Days | 2.484 (0.67) A | 7.557 (1.91) | 4.000 (1.32) | 0.00020 | |
| 45 Days | 2.431 (1.41) A | 8.103 (3.63) | 5.297 (1.27) | 0.00020 | |
| 60 Days | 2.599 (1.94) A | 7.862 (1.03) | 5.363 (1.93) | 0.00018 | |
| 75 Days | 2.553 (0.62) A | 8.674 (1.93) | 7.737 (1.76) | 0.00021 | |
| Harmonize | 3 Days | 2.425 (0.28) A | 4.845 (0.89) | 3.290 (0.69) C | 0.00013 |
| 30 Days | 3.226 (0.49) A | 5.096 (0.64) | 4.459 (1.49) | 0.00150 | |
| 45 Days | 2.190 (0.67) A | 5.286 (1.44) | 3.702 (2.23) A | 0.05790 | |
| 60 Days | 2.964 (0.94) A | 4.874 (1.52) | 4.139 (1.85) | 0.00520 | |
| 75 Days | 2.270 (0.87) A | 4.764 (1.28) | 3.801 (0.85) B | 0.00030 | |
| Filtek™ Z250 | 3 Days | 3.926 (1.31) A | 4.275 (1.34) | 3.752 (1.09) A | 0.65540 |
| 30 Days | 3.827 (1.18) A | 4.879 (1.30) | 4.558 (1.54) | 0.25500 | |
| 45 Days | 3.905 (1.47) A | 5.093 (1.49) | 3.558 (1.19) B | 0.04800 | |
| 60 Days | 3.992 (0.78) A | 5.671 (1.50) | 4.706 (1.67) | 0.03670 | |
| 75 Days | 4.290 (2.28) | 5.741 (2.25) | 4.197 (1.31) | 0.76200 | |
Indicates clinically unacceptable values (ΔE ≥4).
Grouped values with the same superscript are not statistically different (P<0.05).
Figure 1(A) Graphical representation of G-aenial analytical study of the repeated measurements. (B) Graphical representation of Harmonize analytical study of the repeated measurements. (C) Graphical representation of Z250 analytical study of the repeated measurements.
Figure 2(A) Color difference after polishing G-aenial composite. (B) Color difference after polishing Harmonize composite. (C) Color difference after polishing Z250 composite.
Statistical analysis at day 75 post-polishing.
| Resin composite | Immersion period | Staining solution | |||
|---|---|---|---|---|---|
| Distilled water | Coffee | Tomato sauce | |||
| G-aenial | 75 days with polish | 2.226 (0.84) A | 5.416 (0.92) | 5.948 (1.25) | 0.00015 |
| Harmonize | 75 days with polish | 3.871 (0.70) A | 4.423 (0.69) | 3.217 (1.72) A | 0.131 |
| Filtek™ Z250 | 75 days with polish | 4.543 (1.49) | 4.446 (1.64) | 4.863 (1.51) | 0.82 |
Indicates clinically unacceptable values (ΔE ≥4).
Grouped values with the same superscript are not statistically different (P<0.05).