Assessment of changes in color and color parameters of light-cured composite resin after alternative polymerization methods.

Emine Sirin Karaarslan1, Mehmet Bulbul, Ertan Ertas, Mehmet Ata Cebe, Aslihan Usumez.   

Abstract

OBJECTIVE: To examine the amount of change in color and color parameters of a composite resin (Filtek P60) polymerized by five different polymerization methods.
METHODS: A Teflon mold (6mm in diameter, 2mm in height) was used to prepare the composite resin discs (n=10). G1: Polymerization with inlay oven; G2: Polymerization with HQTH and autoclave; G3: Polymerization with LED and autoclave; G4: Polymerization with HQTH; G5: Polymerization with LED. Colorimetric values of the specimens before and after polymerization were measured using a spectrophotometer. The CIE L*a*b color system was used for the determination of color difference. Analysis of variance (ANOVA) was used to analyze the data for significant differences. Tukey's HSD test and paired two-tailed tests were used to perform multiple comparisons (α=.05).
RESULTS: There were no significant differences in total color change (ΔE*ab) among the polymerization groups (P>.05). However, the lowest color change (ΔE*ab) value was 3.3 in LED and autoclave; the highest color change (ΔE*ab) value was 4.6 in HQTH. For all groups, CIE L*, C*ab and a*values decreased after polymerization (P<.05). The highest Δb* and ΔC*ab values were observed in specimens polymerized in an inlay oven (P<.05).
CONCLUSIONS: Composite resin material showed color changes above the clinically accepted value in all study groups (ΔE*ab⩾3.3). All specimens became darker during investigation (ΔL*< 0). Specimens polymerized with inlay oven presented the highest Δb* values which means less yellow color in specimens.

Entities:  

Keywords:  Composite resin; color change; inlay oven; polymerization methods

Year:  2013        PMID: 23407793      PMCID: PMC3571518     

Source DB:  PubMed          Journal:  Eur J Dent


INTRODUCTION

The importance of esthetic in dentistry is well known.1 It has been reported, for example, that esthetic dental restorative treatment can improve a patient’s self-esteem.2 Initial shade matching of an uncured composite resin material to its adjacent tooth is an important clinical practice in esthetic restorative procedures, and once an appropriate match is obtained, the color match should be maintained after polymerization. However, optical properties of dental composite resins change as a result of polymerization, and the extent of change is influenced by the characteristics of the material and wavelength.3,4 Lighter or less chromatic shades tend to show higher color changes than more chromatic or darker shades.5 To compensate this color change, an initial color choice that is more yellow or more chromatic than the needed final color has been suggested in clinical applications.6 The most extensively used light source for photoactivating a composite resin material is quartz tungsten halogen (QTH) lights.7 The QTH with higher light intensities (HQTH) were introduced in dentistry. Decreasing the total cure time for adhesive and composite materials is useful for both the clinician and the patient. Additionally, higher curing light intensities may lead to superior physical and mechanical properties.8 Light-emitting diode (LED) curing lights are used to polymerize resin-based restorative materials, and their effect on the physical properties of resin-based restorative materials has been investigated.9 Because contemporary LED lights yield superior irradiance (approximately 1,000 mW/cm2) to QTH light (approximately 800 mW/cm2), LED lights are expected to polymerize resin materials as or even more effective than QTH.9 Post-cure heating of resin composite materials is a extremely popular restorative technique. This method subjects a light-cured composite inlay to an immediate heat treatment for the purpose of increasing material cure and thus enhancing clinical properties.10 In Rueggeberg’s study, the degree of color change was influenced more by the amount of resin content in the composite systems than by the particular resin composition. Microfill composite resins showed greater potential for color change than did the other types of materials. If clinicians are considering using conventional light-cured composite materials for inlays, the choice of material as well as the post-cure temperature will influence the ability to match the inlay with the initial shade of composite chosen.11 An important factor is the possibility of using post-polymerization mechanisms associated with heat, pressure, or high light intensity in indirect composite systems.12 With respect to materials, indirect and direct composites have similar compositions.13 Currently, easy and inexpensive techniques have been enhanced for direct composites in indirect restorations. Coupled with the use of devices that are always found in dentists’ offices to apply these techniques, better performance can now be obtained and harnessed from material properties, resulting in improved dental health.14 Presently, electronic shade-matching instruments have been used for dental practice.15 In order to determine objectively the color changes on composite restorations, some methods have been experienced, among them the spectrophotometry, which makes the study of several parameters related to color stability of composite resins possible. In this method reflected wavelength by a body is changed in values expressed in ΔE* units. The ΔE* values can be used so that present the color changes provided by the composite resin after treatment or period of time.16 Instrumental color analysis offers a potential advantage over visual color determination, as instrumental readings are objective, quantifiable, and more rapidly obtainable.17 The Comission Internationale de l’Eclairage Lab (CIE L*a*b) color system has been used for determination of color difference.18–21 Chroma is calculated as C*ab= (a*2+ b*2) ½.4 The total color difference ΔE*ab between two color stimuli, each given in terms of L*, a*, b* is calculated from:22ΔE*ab =[(ΔL*)2+(Δa*)2+(Δb*)2]1/2. The L* coordinate is a measure of the lightness-darkness of the specimen. The greater the L* is, the lighter the specimen. The a* coordinate is a measure along the red-green axis. A positive a* relates to the amount of redness, and a negative a* relates to greenness of a specimen. The b* coordinate is a measure along the yellow-blue axis, that is a positive b* relates to the amount of yellowness; a negative b* relates to the amount of blueness of the specimen. ΔL*, Δa* and Δb* are the differences in the CIE color-space parameters of the 2 colors.23 Threshold color difference levels based on instrumental color measurements that can be visually perceivable or clinically acceptable have been discussed. However, the clinically acceptable value for color difference in restorative materials is assumed to be ΔE*⩽ 3.3.24 The aim of this in vitro study was to investigate the amount of change in color and color parameters of composite resin material (Filtek P60, 3M ESPE) polymerized by five different polymerization methods. The null hypothesis of the present study were that (1) the polymerization methods don’t affect the color parameters of composite resin material, (2) there is no color difference between unpolymerized and polymerized composite resin regarding the polymerization methods.

MATERIALS AND METHODS

The composite resin used in this study was Filtek P60 (color A3; 3M ESPE, St. Paul, U.S.A.) packable light-cured composite. A 6mm diameter hole was made in a 2mm high Teflon plate and filled with composite resin. After inserting the composite resin material into the Teflon plate, a strip was laid on the top of the specimens and the color of the composite specimens before polymerization was measured on stripped surfaces. Five groups were considered for color change (n=10) (Table 1).
Table 1

Prortocols of polymerization in this study.

GroupsPolymerization typeCuring unitManufacturerPolymerization time
Group IInlay ovenTescera inlay ovenBisco, USA15 min
Group IIHQTH unit and autoclaveBlue Luxer and Europa B xpMonitex, Taiwan and Tecnogaz, Italy30 sn and 17 min
Group IIILED unit and autoclaveDemi led and Europa B xpKerr, USA and Tecno-gaz, Italy20sn and 17 min
Group IVHQTH unitBlue LuxerMonitex, Taiwan30 sn
Group VLED unitDemi ledKerr, USA20sn
Group I: Polymerization with inlay oven (Tescera ATL, Bisco, USA) for 15 minutes. Group II: Conventional polymerization with HQTH unit (High Quartz Tungsten Halogen Blue Luxer, Monitex, Taipei, Taiwan) at 740 mW/cm2 for 30 seconds and post-polymerized in an autoclave (Europa B xp, Tecno-gaz, Italy) at 30 PSI pressure, 134°C heat for 17 minutes. Group III: Conventional polymerization with LED unit (Light-Emitting Diode Demi, Kerr, Orange, USA) at 1100 mW/cm2 for 20 seconds and post-polymerized in an autoclave (Europa B xp, Tecno-gaz, Italy) at 30 PSI pressure, 134°C heat for 17 minutes. Group IV: Conventional polymerization only with HQTH unit (Blue Luxer, Monitex, Taipei, Taiwan) at 740 mW/cm2 for 30 seconds. Group V: Conventional polymerization only with LED unit (Demi, Kerr, Orange, USA) at 1100mW/cm2 for 20 seconds. The plate was reversed so that the lower side of the plate was on top. The composite was once again irradiated for the same irradiation times. The characteristics, polymerization times, and polymerization protocols of the light-curing units, inlay oven, and autoclave used are shown in Table 1. After polymerization, no polishing techniques were used in order to avoid modification of the surfaces, which could influence the results.25 Colorimetric values of the composite resin specimens before and after polymerization were measured using a spectrophotometer (Vita Easy-Shade, Vident, No: 502744, USA). The spectrophotometer comprises a base unit and a handpiece. In this system, the specimen was exposed to an emission of light, and the reflected light was analyzed with a spectrophotometer. Instrument calibration was evaluated after measurement of each group (n=10) and recalibration. The tip of the handpiece was placed firmly into the calibration port and was held steadily in place until the instrument sounded a beep to indicate that calibration was complete. The measuring tip of the spectrophotometer was a circle 5 mm in diameter. Color measurement was performed in consecutive tests on central parts of the specimens. Specimens were positioned at the same place on different occasions to ensure consistency of the repeated measurements. A white plate was used for the background color in this study.22,26 All specimens were chromatically measured three times, and the average values were calculated. CIE L*a*b color system was used for determination of color difference. Changes in color coordinates (ΔL* Δa*and Δb*) were calculated as ‘the value after polymerization – the value before polymerization’. The formula of ΔE*ab:

Statistical analysis

The data were entered into a spreadsheet (Excel; version 4.0, Microsoft, Seattle, WA, USA) for calculation of descriptive statistics. Analysis of variance (ANOVA) was used to analyze the data for significant differences. Tukey’s HSD test and paired two-tailed tests were used to perform multiple comparisons (α=.05). The data were analyzed with the SPSS 13 for Windows statistical program software (SPSS Inc., Chicago, IL, USA).

RESULTS

Colorimetric values of composite resin after polymerization are listed in Table 2. There were noticeable color changes in all groups (ΔE*ab ⩾ 3.3). The range of changes in composite resin according to polymerization methods was 3.3–4.6 in color (ΔE*ab: distribution span: 1.2), −1.0 to −1.6 in ΔL* (distribution span: −0.6), −1.5 to −2.8 in ΔC*ab (distribution span: −1.3), −4.0 to −2.6 in Δa* (distribution span: −1.4), −1.7 to −0.5 in Δb* (distribution span: −1.2). There were no significant differences in color change among the groups (P>.05).
Table 2

Changes in color and color parameters after polymerization.

Polymerization MethodsΔE*abΔC*abΔL*Δa*Δb*
Inlay oven4,2 (0.6)a−2.8 (0.3)−1.6 (0.5)−3.4 (0.7)−1.7 (0.4)
HQTH unit and autoclave3,8 (1.2)−1.6 (0.3)−1.1 (1.0)−3.4 (1.5)−0.5 (0.7)
LED unit and autoclave3,3 (1.4)−1.5 (0.3)−1.0 (1.7)−2.6 (1.5)−0.7 (0.5)
HQTH unit4,6 (0.5)−1.8 (0.4)−1.3 (1.9)−4.0 (0.9)−0.5 (0.5)
LED unit3,9 (1.2)−1.9 (0.4)−1.4 (1.0)−3.4 (1.0)−0.8 (0.4)

Values in parentheses indicate standard deviation

There were no significant differences in CIE L* value (P>.05) among the groups. C*ab value was affected by polymerization methods (P<.05). There were significant differences between the inlay oven and the other four groups (P<.05). While the lowest ΔC*ab value was observed in polymerization with LED and autoclave, the highest ΔC*ab value was observed in polymerization with the inlay oven. Also, there were significant differences between polymerization with LED and autoclave and the HQTH light curing unit (P<.05). The CIE a* value was not affected by polymerization methods. The CIE a* value shifted toward green (Δa*< 0). But, there were no significant differences among groups (P>.05). The CIE b* value was affected by polymerization methods (P<.05). The CIE b* values of the inlay oven polymerization group is significantly differences from the other four groups (P<.05). The composite resins polymerized with the inlay oven showed the highest Δ*b values which means less yellow color in specimens. For all groups, CIE L* values decreased after polymerization, all specimens became darker during investigation (ΔL*< 0). In all groups, C*ab and CIE a* values decreased after polymerization (P<.05). The CIE a* value shifted toward green (Δa*< 0). CIE b* values decreased after polymerization (Δb*< 0), indicating the increase of blue color and the decrease of yellow color factor (P<.05). There were significant differences b1 and b0 (after and before) in the inlay oven polymerization group, LED and autoclave, LED, and HQTH (P<.05). Mean changes in color and color parameters by the polymerization methods are presented in Figure 1.
Figure 1

Mean changes in color parameters by the brand of resin composites.

DISCUSSION

This in vitro study measured the amount of the changes in color and color parameters of composite resin material polymerized by five different polymerization methods. Based on the results of the present study, the first null hypothesis of the present study that the polymerization methods don’t affect the color parameters of composite resin material was partially accepted because color change was not affected by polymerization methods. However, C*ab and b* values were affected by polymerization methods. The second null hypothesis that there is no color difference between unpolymerized and polymerized composite resin regarding the polymerization methods was accepted. The results of the present study demonstrated that there were color changes in all groups. ΔE*ab values of specimens were ⩾3.3. The lowest color change (ΔE*ab) value was 3.3 in polymerization with LED and autoclave; the highest color change (ΔE*ab) value was 4.6 in polymerization with HQTH. The polymerization color changes of resin composites were investigated, and the range of color change was 2.6–4.1. ΔE*ab units depended on the shade.27 Changes in CIE L* parameter (lightness) after polymerization were significant for all materials, and changes in the lightness had the greatest influence on polymerization color change.27 In the current study, Filtek P60 A3 shade composite resin was used. There were no significant differences in ΔE*ab value among the groups. In all groups, CIE L* value decreased after polymerization, but there were no significant differences among the groups. Further in vitro study on this subject should be performed. Filtek™ P60 restorative material is a visible light-activated, radiopaque, restorative composite designed for use in posterior restorations. According to the manufacturer’s instructions, Filtek™ P60 composite resin material is indicated for use in indirect restorations including inlays, onlays and veneers. Thus, in the current study we polymerized this composite resin material in inlay and light sources followed by additional time in an autoclave. Light sources have been used to convert the composite, and have been investigated whether there is a correlation between the intensity of light source, time of exposure, types of material, and distance from the tooth to the curing source.28 Light-sensitive materials contain camphorquinone (CQ) to react with a reducing agent when activated, and activating it to polymerization requires sufficient light intensity and a suitable wavelength.29 CQ significantly influences the color of the material30 as it is a yellow chemical compound. During light irradiation at 478nm wavelength, it changes color and becomes colorless. However, if irradiation is not enough, a certain amount of yellow will remain.31 In the present study, specimens polymerized with different polymerization units revealed a color shift from yellow to blue (Δb*<0) and from red to green (Δa*<0) after polymerization. All specimens became darker during investigation (ΔL*<0). The same phenomenon, in term as decrease in b* value after resin composite polymerization was also reported by Sidhu et al.32 It is well known that inadequate polymerization adversely affects the mechanical properties of composite materials in terms of strength, color stability,29 hardness,12 and wear resistance.33 When post-polymerization methods are used, material properties can be improved.14 Post-cure heating of resin composite materials has become a very popular restorative technique.34 Many properties enhanced by post-cure heating, such as fracture toughness, flexural modulus, and flexural strength, were found to decrease to levels identical to those of the light-cured-only group35 when the specimens were subjected to water storage after curing. The various methods of post-curing (light, heat, pressure, vacuum, and nitrogen) allow for secondary curing of the composite by increasing the conversion of the resin material from monomer to polymer.36 In their research, Silva et al37 used different laboratory photo curing units and conventional halogen light sources followed by additional in an autoclave. They reported that the use of light curing in conjunction with heat and pressure curing improved the mechanical properties of resin composites and the use of alternative polymerization with conventional photo curing; the autoclave was shown to be feasible, with a wide implication for the general public in terms of reduced dental treatment cost. The amount of color changes of composite resin material polymerized by inlay oven and light sources followed by additional time in an autoclave was evaluated in the current study. But, there were no significant differences in color change among groups. The polymerization process in Indirect Inlay System (Tescera ATL, Bisco, USA) combines two curing mechanisms: light and heat under water. After complete development of the restoration, the final cure is accomplished in a heat cup with the restoration submerged in water.38,39 In the current study, CIE b* value (yellow-blue) decreased after polymerization. The composite resins that polymerized with inlay oven showed the highest Δ*b values which means less yellow color in specimens. The CIE *b values of the polymerization inlay oven is significantly different from the other four groups. The highest ΔC*ab values were observed in specimens polymerized in an inlay oven. In this inlay system, the final cure is accomplished in a heat cup with the restoration submerged in water. Therefore, the highest Δ*b and ΔC*ab values may be observed in this polymerization system. Further in vitro study on this subject should be performed. Polymerized composite resins tend to have greater diffuse reflectance than unpolymerized composite resins. This alteration reflects the increase of refractive index of the resin phase associated with monomer conversion (into polymer) of monomer mixtures, while refractive index of the filler remains unchanged.3 Lee and Powers40 reported that lightness (CIE L*) increased or decreased depending on the material and shade after polymerization. In their study, Kim and Lee4 reported that CIE L* values decreased after polymerization except one composite resin. A study by Marais et al41 has suggested that power density (irradiance) does not have an effect on conversion of composite resin at depths beyond 2 mm; because of this, in the current study, specimen thickness was 2 mm. The specimens were cured from both sides, effectively reducing thickness of resin being cured to 1 mm to get maximum conversion. Tak et al22 used 2mm-thick specimens. In the previous study, the specimen thickness was 1mm.4 The difference in thickness may influence the amount of color change after polymerization.

CONCLUSIONS

Within the limitations of this in vitro study, the following conclusions were drawn: - The color changes of composite resin material in all groups were above the clinically acceptable value (ΔE*ab ⩾3.3). There were no significant differences in total color change among the groups. - All specimens became darker during investigation (ΔL*< 0). - The composite resins that polymerized with inlay oven showed the highest Δ*b values which means less yellow color in specimens.
  39 in total

1.  Influence of illuminating and viewing aperture size on the color of dental resin composites.

Authors:  Yong-Keun Lee; Bum-Soon Lim; Cheol-We Kim
Journal:  Dent Mater       Date:  2004-02       Impact factor: 5.304

2.  Color and opacity variations in three different resin-based composite products after water aging.

Authors:  Alessandro Vichi; Marco Ferrari; Carel Leon Davidson
Journal:  Dent Mater       Date:  2004-07       Impact factor: 5.304

3.  Effect of LED light-curing on the relative hardness of tooth-colored restorative materials.

Authors:  Enas Mobarak; Iman Elsayad; Magdi Ibrahim; Wafa El-Badrawy
Journal:  Oper Dent       Date:  2009 Jan-Feb       Impact factor: 2.440

4.  Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins.

Authors:  J L Ferracane
Journal:  Dent Mater       Date:  1985-02       Impact factor: 5.304

5.  Color stability of dental composite resin materials for crown and bridge veneers.

Authors:  I E Ruyter; K Nilner; B Moller
Journal:  Dent Mater       Date:  1987-10       Impact factor: 5.304

6.  A comparative study of shade-matching procedures.

Authors:  W D Culpepper
Journal:  J Prosthet Dent       Date:  1970-08       Impact factor: 3.426

7.  Effects of mouth rinses on color stability of resin composites.

Authors:  Cigdem Celik; Bulem Yuzugullu; Selim Erkut; Kıvanc Yamanel
Journal:  Eur J Dent       Date:  2008-10

8.  Effect of in-office bleaching on color and surface roughness of composite restoratives.

Authors:  Randa Hafez; Doa Ahmed; Mai Yousry; Wafa El-Badrawy; Omar El-Mowafy
Journal:  Eur J Dent       Date:  2010-04

9.  Mechanical properties of light-curing composites polymerized with different laboratory photo-curing units.

Authors:  Gisele Rodrigues da Silva; Paulo Cezar Simamoto-Júnior; Adérito Soares da Mota; Carlos José Soares
Journal:  Dent Mater J       Date:  2007-03       Impact factor: 2.102

10.  Restorative resins: hardness and strength vs. quantity of remaining double bonds.

Authors:  E Asmussen
Journal:  Scand J Dent Res       Date:  1982-12
View more
  6 in total

1.  Effect of vulcanization temperature and dental stone colour on colour degradation of maxillofacial silicone elastomers.

Authors:  Ebru Demet Cifter; Meltem Ozdemir-Karatas; Emrah Baca; Adem Cinarli; Ali Balik; Erkan Sancakli; Bilge Gokcen-Rohlig
Journal:  BMC Oral Health       Date:  2017-03-31       Impact factor: 2.757

2.  A study of fractal dimension as a quality indicator of hairtail (Trichiurus haumela) samples during frozen storage.

Authors:  Lanlan Luan; Yeshun Sun; Shiguo Chen; Chunhua Wu; Yaqin Hu
Journal:  Sci Rep       Date:  2018-11-07       Impact factor: 4.379

3.  Changes in color and contrast ratio of resin composites after curing and storage in water.

Authors:  Marlus da Silva Pedrosa; Fernando Neves Nogueira; Vitor de Oliveira Baldo; Igor Studart Medeiros
Journal:  Saudi Dent J       Date:  2021-02-20

4.  Transcriptome Co-expression Network and Metabolome Analysis Identifies Key Genes and Regulators of Proanthocyanidins Biosynthesis in Brown Cotton.

Authors:  Zhenzhen Wang; Xiaomeng Zhang; Shoupu He; Abdul Rehman; Yinhua Jia; Hongge Li; Zhaoe Pan; Xiaoli Geng; Qiong Gao; Liru Wang; Zhen Peng; Xiongming Du
Journal:  Front Plant Sci       Date:  2022-02-14       Impact factor: 5.753

5.  Laboratory evaluation of the potential masking of color changes produced by silver diamine fluoride in primary molars.

Authors:  Dina Hamdy; Maria Giraki; Amr Abd Elaziz; Amira Badran; Gehan Allam; Stefan Ruettermann
Journal:  BMC Oral Health       Date:  2021-07-09       Impact factor: 2.757

6.  Discoloration of Resin Composites Induced by Coffee and Tomato Sauce and Subjected to Surface Polishing: An In Vitro Study.

Authors:  Cendrella Assaf; Philippe Abou Samra; Paul Nahas
Journal:  Med Sci Monit Basic Res       Date:  2020-06-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.