High-speed visualization of ingested, ejected, adherent, and disintegrated thrombus in contemporary ventricular assist devices.

Grant W Rowlands1, James F Antaki1.   

Abstract

Biocompatibility of ventricular assist devices (VADs) has been steadily improving, yet the rate of neurological events remains unacceptably high. Recent speculation for elevated stroke rates centers on ingestion of thrombi originating upstream of the pump, such as in the ventricle or left atrial appendage. These thrombi may be ejected by the VAD or become deposited within the blood flow pathway, presenting serious complications to the patient. This study was performed to visualize and quantify the degree of disruption, adherence, and disintegration of thrombi that are ingested by the three most implanted VADs: the HeartMate II, HeartMate 3, and HVAD. Clot analogs of varying microstructure compositions (red, white) and sizes (0.5, 1, 2 cm3 ) were synthesized in vitro based on clinical explant data. These were introduced individually into an in vitro flow loop with a transparent replica of the HMII, HM3, and HVAD operated at nominal steady flow (2.3-4.0 L/min). High-speed videography (up to 10 000 fps) revealed the ingestion, disruption, ejection, and adherence of thrombus fragments. Thromboemboli of varying compositions and sizes were observed mechanically attaching to components in all 3 VAD models. In some instances, ingested thrombi physically obstructed portions of the blood flow path; 18% (3 of 17 total) of red thrombi adhered to the inflow straightener of the transparent HMII. In the HVAD model, fewer than 4% of clots were adherent or trapped within the pump, irrespective of microstructure or initial volume. In comparison, 100% (4 of 4 total) of 1-cm3 white (fibrin) clots became lodged within the transparent HM3 while, in contrast, less than 5% of macerated red clots (3 of 63 total) of the same volume were adherent inside the pump. A significant proportion of ingested thrombi were macerated into infinitesimal fragments; 84% and 74% of 2-cm3 red thrombi in the HVAD and HM3 models, respectively, were found to have disintegrated upon ingestion. However, large emboli were also discharged from both centrifugal VADs; these fragments, ranging from 0.01 to 0.29 cm3 regardless of microstructure and original volume, may be capable of occluding an intracranial vessel. Therefore, ingested thrombus may explain, in part, elevated stroke rates in contemporary blood pumps in the absence of adherent pump thrombosis.
© 2020 International Center for Artificial Organ and Transplantation (ICAOT) and Wiley Periodicals LLC.

Entities:  

Keywords:  HVAD; HeartMate 3; HeartMate II; pump thrombosis; stroke; thrombus ingestion

Year:  2020        PMID: 32530104     DOI: 10.1111/aor.13753

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  A New Mathematical Numerical Model to Evaluate the Risk of Thrombosis in Three Clinical Ventricular Assist Devices.

Authors:  Yuan Li; Hongyu Wang; Yifeng Xi; Anqiang Sun; Xiaoyan Deng; Zengsheng Chen; Yubo Fan
Journal:  Bioengineering (Basel)       Date:  2022-05-27

2.  Effects of the atrium on intraventricular flow patterns during mechanical circulatory support.

Authors:  Mojgan Ghodrati; Thomas Schlöglhofer; Alexander Maurer; Thananya Khienwad; Daniel Zimpfer; Dietrich Beitzke; Francesco Zonta; Francesco Moscato; Heinrich Schima; Philipp Aigner
Journal:  Int J Artif Organs       Date:  2021-10-29       Impact factor: 1.595

3.  Inflow cannula position as risk factor for stroke in patients with HeartMate 3 left ventricular assist devices.

Authors:  Thomas Schlöglhofer; Philipp Aigner; Marcel Migas; Dietrich Beitzke; Kamen Dimitrov; Franziska Wittmann; Julia Riebandt; Marcus Granegger; Dominik Wiedemann; Günther Laufer; Francesco Moscato; Heinrich Schima; Daniel Zimpfer
Journal:  Artif Organs       Date:  2022-01-09       Impact factor: 2.663

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.