Literature DB >> 3252971

Velocity fields and turbulent stresses downstream of biological and mechanical aortic valve prostheses implanted in pigs.

J M Hasenkam1, E M Pedersen, J H Ostergaard, H Nygaard, P K Paulsen, G Johannsen, B A Schurizek.   

Abstract

Since detailed knowledge about velocity fields downstream of heart valve prostheses obtained from in vitro studies has not been followed up by similar detailed studies in vivo a pig model for acute velocity field studies downstream of aortic valve prostheses was established. Two mechanical and two bioprosthetic valves were studied and a dynamic three dimensional visualisation of velocity fields one diameter downstream performed under different haemodynamic conditions in a total of 22 pigs. The Ionescu-Shiley pericardial valve had velocity fields very similar to the normal native porcine aortic valve. The Edwards-Carpentier porcine valve caused a jet type flow, and the valve design of the St Jude Medical and Björk-Shiley Monostrut valves was reflected in the velocity profile. Normalised (mean(SEM] systolic Reynolds normal stresses in the total cross sectional area were: native porcine 15(1.5) Nm-2; St Jude Medical 24(3.4) Nm-2; Björk-Shiley Monostrut 25(1.6) Nm-2; Edwards-Carpentier Supra-annular 51(6.6) Nm-2; Ionescu-Shiley Pericardial 19(2.0) Nm-2. Reynolds normal stresses were higher in areas of rapidly changing or constantly high velocity gradients.

Entities:  

Mesh:

Year:  1988        PMID: 3252971     DOI: 10.1093/cvr/22.7.472

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  5 in total

1.  Performance of short-time spectral parametric methods for reducing the variance of the Doppler ultrasound mean instantaneous frequency estimation.

Authors:  H Sava; L G Durand; G Cloutier
Journal:  Med Biol Eng Comput       Date:  1999-05       Impact factor: 2.602

2.  Assessment of prosthetic aortic valve performance by magnetic resonance velocity imaging.

Authors:  R Botnar; E Nagel; M B Scheidegger; E M Pedersen; O Hess; P Boesiger
Journal:  MAGMA       Date:  2000-02       Impact factor: 2.310

3.  A new perivascular multi-element pulsed Doppler ultrasound system for in vivo studies of velocity fields and turbulent stresses in large vessels.

Authors:  H Nygaard; J M Hasenkam; E M Pedersen; W Y Kim; P K Paulsen
Journal:  Med Biol Eng Comput       Date:  1994-01       Impact factor: 2.602

4.  Transcatheter Heart Valve Downstream Fluid Dynamics in an Accelerated Evaluation Environment.

Authors:  Sailahari V Ponnaluri; Steven Deutsch; Michael S Sacks; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2021-02-26       Impact factor: 3.934

5.  Development of an animal experimental model for a bileaflet mechanical heart valve prosthesis.

Authors:  Suk Jung Choo; Kun Il Kim; Nam Hee Park; Jong Min Song; In Cheol Choi; Jee Yeon Shim; Sang Kwon Lee; Young Joo Kwon; Chang Nyung Kim; Jae Won Lee
Journal:  J Korean Med Sci       Date:  2004-02       Impact factor: 2.153

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.