BACKGROUND/AIMS: To compare the accuracy of 13 formulas for intraocular lens (IOL) power calculation in cataract surgery.
METHODS: In this retrospective interventional case series, optical biometry measurements were entered into these formulas: Barrett Universal II (BUII) with and without anterior chamber depth (ACD) as a predictor, EVO 2.0 with and without ACD as a predictor, Haigis, Hoffer Q, Holladay 1, Holladay 2AL, Kane, Næser 2, Pearl-DGS, RBF 2.0, SRK/T, T2 and VRF. The mean prediction error (PE), median absolute error (MedAE), mean absolute error and percentage of eyes with a PE within ±0.25, ±0.50, ±0.75 and ±1.00 diopters (D) were calculated.
RESULTS: Two hundred consecutive eyes were enrolled. With all formulas, the mean PE was zero. The BUII with no ACD had the lowest standard deviation (±0.343 D), followed by the T2 (0.347 D), Kane (0.348 D), EVO 2.0 with no ACD (0.348 D) and BUII with ACD (0.353 D) formulas. The difference among the MedAEs of all formulas was statistically significant (p<0.0001); the lowest values were achieved with the Kane (0.214 D), RBF 2.0 (0.215 D), BUII with and without ACD (0.218 D) and SRK/T (0.223 D). A percentage ranging from 80% to 88.5% of eyes showed a PE within ±0.50 D and all formulas achieved more than 50% of eyes with a PE within ±0.25 D.
CONCLUSION: All investigated formulas achieved good results; there was a tendency towards better outcomes with newer formulas. Traditional formulas can still be considered an accurate option. © Author(s) (or their employer(s)) 2021. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  lens and zonules; optics and refraction

Year:  2020        PMID: 32522789     DOI: 10.1136/bjophthalmol-2020-316193

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  10 in total

1.  Accuracy of new-generation intraocular lens calculation formulas in eyes with variations in predicted refraction.

Authors:  Pingjun Chang; Shuyi Qian; Yalan Wang; Siyan Li; Fuman Yang; Yiwen Hu; Zhuohan Liu; Yun-E Zhao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-08       Impact factor: 3.117

2.  Influence of the invariant refraction assumption in studies of formulas for monofocal and multifocal intraocular lens power calculation.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Noemi Burguera; David Piñero
Journal:  Int Ophthalmol       Date:  2022-02-08       Impact factor: 2.029

3.  Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes.

Authors:  Ling Wei; Kaiwen Cheng; Wenwen He; Xiangjia Zhu; Yi Lu
Journal:  Eye Vis (Lond)       Date:  2022-06-09

4.  A comparative analysis of 12 intraocular lens power formulas.

Authors:  Austin Pereira; Marko M Popovic; Yusuf Ahmed; John C Lloyd; Sherif El-Defrawy; John Gorfinkel; Matthew B Schlenker
Journal:  Int Ophthalmol       Date:  2021-07-27       Impact factor: 2.031

5.  VRF-G, a New Intraocular Lens Power Calculation Formula: A 13-Formulas Comparison Study.

Authors:  Diogo Hipólito-Fernandes; Maria Elisa Luís; Pedro Gil; Vitor Maduro; João Feijão; Tun Kuan Yeo; Oleksiy Voytsekhivskyy; Nuno Alves
Journal:  Clin Ophthalmol       Date:  2020-12-16

Review 6.  Applications of Artificial Intelligence in Myopia: Current and Future Directions.

Authors:  Chenchen Zhang; Jing Zhao; Zhe Zhu; Yanxia Li; Ke Li; Yuanping Wang; Yajuan Zheng
Journal:  Front Med (Lausanne)       Date:  2022-03-11

7.  Comparison of Formula-Specific Factors and Artificial Intelligence Formulas with Axial Length Adjustments in Bilateral Cataract Patients with Long Axial Length.

Authors:  Chuang Li; Mingwei Wang; Rui Feng; Feiyan Liang; Xialin Liu; Chang He; Shuxin Fan
Journal:  Ophthalmol Ther       Date:  2022-08-02

8.  Impact of Global Optimization of Lens Constants on Absolute Prediction Error for Final IOL Power Selection When Using Intraoperative Aberrometry.

Authors:  John Davidson; Xiaolin Gu; Michael Breen; Raiju J Babu
Journal:  Clin Ophthalmol       Date:  2022-09-27

9.  Accuracy of the Barrett Universal II formula integrated into a commercially available optical biometer when using a preloaded single-piece intraocular lens.

Authors:  Hiroki Mieno; Osamu Hieda; Toshihide Ikeda; Shino Hayashi; Masatsugu Hashida; Kimiaki Urabe; Chie Sotozono
Journal:  Indian J Ophthalmol       Date:  2021-09       Impact factor: 1.848

10.  Nationwide multicentre comparison of preoperative biometry and predictability of cataract surgery in Japan.

Authors:  Kazutaka Kamiya; Ken Hayashi; Mao Tanabe; Hitoshi Tabuchi; Masaki Sato; Norihito Gotoh; Takashi Kojima; Natsuko Hatsusaka
Journal:  Br J Ophthalmol       Date:  2021-06-09       Impact factor: 5.908

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.