Literature DB >> 32517988

Elucidating failure mechanisms in human femurs during a fall to the side using bilateral digital image correlation.

Lorenzo Grassi1, Joeri Kok2, Anna Gustafsson2, Yi Zheng3, Sami P Väänänen4, Jukka S Jurvelin5, Hanna Isaksson2.   

Abstract

An improved understanding of the mechanical properties of human femurs is a milestone towards a more accurate assessment of fracture risk. Digital image correlation (DIC) has recently been adopted to provide full-field strain measurements during mechanical testing of femurs. However, it has typically been used to measure strains on the anterior side of the femur, whereas in both single-leg-stance and sideways fall loading conditions, the highest deformations result on the medial and lateral sides of the femoral neck. The goal of this study was to measure full-field deformations simultaneously on the medial and lateral side of the femoral neck in a configuration resembling a fall to the side. Twelve female cadaver femurs were prepared for DIC measurements and tested in sideways fall at 5 mm/s displacement rate. Two pairs of cameras recorded the medial and lateral side of the femoral neck, and deformations were calculated using DIC. The samples exhibited a two-stage failure: first, a compressive collapse on the superolateral side of the femoral neck in conjunction with peak force, followed by complete femoral neck fracture at the force drop following the post-elastic phase. DIC measurements corroborated this observation by reporting no tensile strains above yield limit for the medial side of the neck up to peak force. DIC measurements registered onto the bone micro-architecture showed strain localizations in proximity of cortical pores due to, for instance, blood vessels. This could explain previously reported discrepancies between simulations and experiments in regions rich with large pores, like the superolateral femoral neck.
Copyright © 2020 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Digital image correlation; Direction of principal strain; Femurs; Hip fractures; Mechanical testing; Sideways fall; Strain distribution

Mesh:

Year:  2020        PMID: 32517988     DOI: 10.1016/j.jbiomech.2020.109826

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Three-dimensional surface strain analyses of simulated defect and augmented spine segments: A biomechanical cadaveric study.

Authors:  Asghar Rezaei; Maryam Tilton; Hugo Giambini; Yong Li; Alexander Hooke; Alan L Miller Ii; Michael J Yaszemski; Lichun Lu
Journal:  J Mech Behav Biomed Mater       Date:  2021-04-23

2.  Body Anthropometry and Bone Strength Conjointly Determine the Risk of Hip Fracture in a Sideways Fall.

Authors:  Marco Palanca; Egon Perilli; Saulo Martelli
Journal:  Ann Biomed Eng       Date:  2020-11-12       Impact factor: 3.934

3.  Experimental validation of a voxel-based finite element model simulating femoroplasty of lytic lesions in the proximal femur.

Authors:  Amelie Sas; An Sermon; G Harry van Lenthe
Journal:  Sci Rep       Date:  2022-05-09       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.