Literature DB >> 32517973

Evaluation of musculoskeletal modelling parameters of the shoulder complex during humeral abduction above 90°.

Maximilian Aurbach1, Jan Spicka2, Franz Süß3, Sebastian Dendorfer3.   

Abstract

Based on electromyographic data and force measurements within the shoulder joint, there is an indication that muscle and resulting joint reaction forces keep increasing over an abduction angle of 90°. In inverse dynamics models, no single parameter could be attributed to simulate this force behaviour accordingly. The aim of this work is to implement kinematic, kinetic and muscle model modifications to an existing model of the shoulder (AnyBody™) and assess their single and combined effects during abduction up to 140° humeral elevation. The kinematics and the EMG activity of 10 test subjects were measured during humeral abduction. Six modifications were implemented in the model: alternative wrapping of the virtual deltoid muscle elements, utilization of a three element Hill model, strength scaling, motion capture driven clavicle elevation/protraction, translation of the GH joint in dependency of the acting forces and an alteration of the scapula/clavicle rhythm. From the six modifications, 16 different combinations were considered. Parameter combinations with the Hill model changed the resultant GH joint reaction force and led to an increase in force during abduction of the humerus above 90°. Under the premise of muscle activities and forces within the GH joint rising after 90° of humeral abduction, we propose that the Hill type muscle model is a crucial parameter for accurately modelling the shoulder. Furthermore, the outcome of this study indicates that the Hill model induces the co-contraction of the muscles of the shoulder without the need of an additional stability criterion for an inverse dynamics approach.
Copyright © 2020. Published by Elsevier Ltd.

Keywords:  EMG; Glenohumeral joint reaction force; Muscle model; Musculoskeletal modelling; Shoulder joint

Mesh:

Year:  2020        PMID: 32517973     DOI: 10.1016/j.jbiomech.2020.109817

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  In Vitro Simulation of Shoulder Motion Driven by Three-Dimensional Scapular and Humeral Kinematics.

Authors:  Hema J Sulkar; Tyler W Knighton; Linda Amoafo; Klevis Aliaj; Christopher W Kolz; Yue Zhang; Tucker Hermans; Heath B Henninger
Journal:  J Biomech Eng       Date:  2022-05-01       Impact factor: 2.097

2.  Computational evidence for nonlinear feedforward modulation of fusimotor drive to antagonistic co-contracting muscles.

Authors:  Russell L Hardesty; Matthew T Boots; Sergiy Yakovenko; Valeriya Gritsenko
Journal:  Sci Rep       Date:  2020-06-30       Impact factor: 4.379

3.  Biomechanical analysis of the right elevated glenohumeral joint in violinists during legato-playing.

Authors:  Anne-Sophie Saffert; Maximilian Melzner; Sebastian Dendorfer
Journal:  Technol Health Care       Date:  2022       Impact factor: 1.285

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.