Literature DB >> 32517556

Use of 3D Printing to Guide Creation of Fenestrations in Physician-Modified Stent-Grafts for Treatment of Thoracoabdominal Aortic Disease.

Yuan-Hao Tong1, Tong Yu1, Min-Jie Zhou2, Chen Liu1, Min Zhou1, Qing Jiang2, Chang-Jian Liu1, Xiao-Qiang Li1, Zhao Liu1,2.   

Abstract

Purpose: To summarize the experience and outcomes of total endovascular repair of thoracoabdominal aortic disease using 3-dimensional (3D) printed models to guide on-site creation of fenestrations in aortic stent-grafts. Materials and
Methods: From April 2018 to March 2019, 34 patients (mean age 58±14 years; 24 men) with thoracoabdominal aortic disease were treated in our department. Nineteen patients had thoracoabdominal aortic dissection and 15 had thoracoabdominal aortic aneurysm. Preoperatively, a 3D printed model of the aorta was made according to computed tomography images. In the operating room, the main aortic stent-graft was completely released in the 3D printed model, and the position of each fenestration or branch was marked on the stent-graft. The fenestrations were then made using an electric pen. Wires were sewn to the edge of the fenestrations using nonabsorbable sutures. After customization, the aortic stent-graft was reloaded into the delivery sheath and deployed.
Results: The printing process took ~5 hours (1 hour for image reconstruction, 3 hours for printing, and 1 hour for postprocessing). The physician-modified stent-grafts had a total of 107 fenestrations secured by 102 bridging stent-grafts, including 73 covered stents and 29 bare stents. The average procedure time was 5.6±1.2 hours, including a mean 1.3 hours for stent-graft customization. No renal insufficiency or paraplegia occurred. Two branch arteries were lost during the operation. One patient (3%) died 1 week after surgery from a retrograde dissection rupture. One patient developed a minor cerebral infarction postoperatively. The mean follow-up time was 8.5 months. There was 1 endoleak from a fenestration (coil embolized) and 4 distal ruptures of the aortic dissection (3 treated and 1 observed).
Conclusion: Three-dimensional printing can be used to guide creation of fenestrated stent-grafts for the treatment of thoracoabdominal aortic diseases involving crucial branches. This technique appears to be more accurate than the traditional measurement method, with short-term follow-up demonstrating the safety and reliability of the method. However, further research and development are needed.

Entities:  

Keywords:  3D printing; aortic aneurysm; aortic dissection; fenestrated stent-grafts; physician-modified stent-grafts; surgeon-modified stent-grafts; thoracoabdominal aorta

Year:  2020        PMID: 32517556     DOI: 10.1177/1526602820917960

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  5 in total

Review 1.  3D printing in the planning and teaching of endovascular procedures.

Authors:  J Stana; M Grab; R Kargl; N Tsilimparis
Journal:  Radiologie (Heidelb)       Date:  2022-09-16

2.  The accuracy and reliability of 3D printed aortic templates: a comprehensive three-dimensional analysis.

Authors:  Pawel Rynio; Maciej Wojtuń; Łukasz Wójcik; Miłosz Kawa; Aleksander Falkowski; Piotr Gutowski; Arkadiusz Kazimierczak
Journal:  Quant Imaging Med Surg       Date:  2022-02

Review 3.  Clinical Applications of Patient-Specific 3D Printed Models in Cardiovascular Disease: Current Status and Future Directions.

Authors:  Zhonghua Sun
Journal:  Biomolecules       Date:  2020-11-20

4.  Effects of Sterilization Methods on Different 3D Printable Materials for Templates of Physician-Modified Aortic Stent Grafts Used in Vascular Surgery-A Preliminary Study.

Authors:  Paweł Rynio; Katarzyna Galant; Łukasz Wójcik; Bartłomiej Grygorcewicz; Arkadiusz Kazimierczak; Aleksander Falkowski; Piotr Gutowski; Barbara Dołęgowska; Miłosz Kawa
Journal:  Int J Mol Sci       Date:  2022-03-24       Impact factor: 5.923

5.  Initial Experience with Fenestrated Physician-Modified Stent Grafts Using 3D Aortic Templates.

Authors:  Paweł Rynio; Tomasz Jedrzejczak; Anita Rybicka; Ross Milner; Piotr Gutowski; Arkadiusz Kazimierczak
Journal:  J Clin Med       Date:  2022-04-13       Impact factor: 4.964

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.