Rikke Buhl1, Eva M Hesselkilde1, Helena Carstensen1, Merle F Fenner1, Thomas Jespersen2, Jacob Tfelt-Hansen3,4, Stefan Michael Sattler2,3. 1. Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. 2. Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. 3. Department of Cardiology, The Heart Centre, Copenhagen University Hospital, Copenhagen, Denmark. 4. Department of Forensic Medicine, Faculty of Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
Abstract
BACKGROUND: Cardiac arrhythmias in horses are diagnosed by auscultation or electrocardiogram (ECG), which results in a low sensitivity for detecting arrhythmias that occur sporadically. Implantable loop recorders (ILRs) are small ECG devices placed subcutaneously, to automatically detect arrhythmias in human patients. OBJECTIVES: To test ILRs ability to detect atrial fibrillation (AF) in horses. Furthermore, we hypothesised that anatomical location of the implant site might influence signal quality. Signal quality was evaluated both during exercise and over time. STUDY DESIGN: Experimental study. METHODS: In five Standardbred mares, eleven ILRs were implanted subcutaneously in up to three different positions (Front: pectoral region, Left-6: sixth left intercostal space and Ventral: xiphoid region) and AF induced. The R- and T-wave amplitudes were measured in all positions over time during AF. AF burden automatically registered by the ILRs over a 2-month period was compared with selected Holter ECG recordings. RESULTS: All three positions had stable R- and T-wave amplitudes during the study period and were of sufficient quality to allow AF detection at rest. The position Left-6 showed significantly higher R- and T-wave amplitudes compared with the other positions. During submaximal exercise only the Left-6 position was able to record ECG signals of diagnostic quality. No position yielded diagnostic signals at maximum exercise due to artefacts. MAIN LIMITATIONS: Few horses and ILRs included and no spontaneous AF episodes were studied. CONCLUSIONS: This preliminary study indicates that ILRs can be used for AF detection in horses, but the anatomical location is important for optimal ECG quality. Despite insufficient quality during exercise, ILRs were suitable for AF detection at rest. Therefore, the ILR may be a valuable diagnostic tool for detecting paroxysmal AF in horses.
BACKGROUND: Cardiac arrhythmias in horses are diagnosed by auscultation or electrocardiogram (ECG), which results in a low sensitivity for detecting arrhythmias that occur sporadically. Implantable loop recorders (ILRs) are small ECG devices placed subcutaneously, to automatically detect arrhythmias in human patients. OBJECTIVES: To test ILRs ability to detect atrial fibrillation (AF) in horses. Furthermore, we hypothesised that anatomical location of the implant site might influence signal quality. Signal quality was evaluated both during exercise and over time. STUDY DESIGN: Experimental study. METHODS: In five Standardbred mares, eleven ILRs were implanted subcutaneously in up to three different positions (Front: pectoral region, Left-6: sixth left intercostal space and Ventral: xiphoid region) and AF induced. The R- and T-wave amplitudes were measured in all positions over time during AF. AF burden automatically registered by the ILRs over a 2-month period was compared with selected Holter ECG recordings. RESULTS: All three positions had stable R- and T-wave amplitudes during the study period and were of sufficient quality to allow AF detection at rest. The position Left-6 showed significantly higher R- and T-wave amplitudes compared with the other positions. During submaximal exercise only the Left-6 position was able to record ECG signals of diagnostic quality. No position yielded diagnostic signals at maximum exercise due to artefacts. MAIN LIMITATIONS: Few horses and ILRs included and no spontaneous AF episodes were studied. CONCLUSIONS: This preliminary study indicates that ILRs can be used for AF detection in horses, but the anatomical location is important for optimal ECG quality. Despite insufficient quality during exercise, ILRs were suitable for AF detection at rest. Therefore, the ILR may be a valuable diagnostic tool for detecting paroxysmal AF in horses.
Authors: A A Leroux; J Detilleux; C F Sandersen; L Borde; R M A C Houben; A Al Haidar; T Art; H Amory Journal: J Vet Intern Med Date: 2013-09-20 Impact factor: 3.333
Authors: Hajime Ohmura; Atsushi Hiraga; Toshiyuki Takahashi; Makoto Kai; James H Jones Journal: J Am Vet Med Assoc Date: 2003-07-01 Impact factor: 1.936
Authors: Charlotte Eitel; Daniela Husser; Gerhard Hindricks; Manuela Frühauf; Sebastian Hilbert; Arash Arya; Thomas Gaspar; Ulrike Wetzel; Andreas Bollmann; Christopher Piorkowski Journal: Europace Date: 2011-02-16 Impact factor: 5.214
Authors: Rikke Buhl; Eva M Hesselkilde; Helena Carstensen; Merle F Fenner; Thomas Jespersen; Jacob Tfelt-Hansen; Stefan Michael Sattler Journal: Equine Vet J Date: 2020-06-28 Impact factor: 2.888
Authors: V B Reef; J Bonagura; R Buhl; M K J McGurrin; C C Schwarzwald; G van Loon; L E Young Journal: J Vet Intern Med Date: 2014-03-14 Impact factor: 3.333
Authors: Rikke Buhl; Eva M Hesselkilde; Helena Carstensen; Merle F Fenner; Thomas Jespersen; Jacob Tfelt-Hansen; Stefan Michael Sattler Journal: Equine Vet J Date: 2020-06-28 Impact factor: 2.888
Authors: Rikke Buhl; Sarah D Nissen; Marie L K Winther; Sofie K Poulsen; Charlotte Hopster-Iversen; Thomas Jespersen; Prashanthan Sanders; Helena Carstensen; Eva M Hesselkilde Journal: Equine Vet J Date: 2020-11-23 Impact factor: 2.888