| Literature DB >> 32500236 |
Verena Plodeck1, Christoph Georg Radosa2, Hans-Martin Hübner2, Christian Baldus2, Angelika Borkowetz3, Christian Thomas3, Jens-Peter Kühn2, Michael Laniado2, Ralf-Thorsten Hoffmann2, Ivan Platzek2.
Abstract
PURPOSE: To assess whether the application of a preparatory micro-enema reduces gas-induced susceptibility artefacts on diffusion-weighted MRI of the prostate.Entities:
Keywords: Artefacts; Diffusion weighted; Enema; Multiparametric magnetic resonance imaging; Prostate cancer
Mesh:
Year: 2020 PMID: 32500236 PMCID: PMC8260527 DOI: 10.1007/s00261-020-02600-9
Source DB: PubMed Journal: Abdom Radiol (NY)
Patient characteristics
| Micro-enema | No enema | |
|---|---|---|
| Mean age (range) | 64 (30–83) | 66 (53–79) |
| Mean prostate volume in ml (range) | 45.8 (9.5–249.3) | 49.7 (19.5–125.7) |
| Mean PSA in ng/ml (range) | 7.7 (0.99–38.3) | 7.8 (1.8–24.5) |
| Prior TURPa | 2 | 2 |
| PIRADS 3 lesions on MRI | 28 | 20 |
| PIRADS 4 lesions on MRI | 18 | 15 |
| PIRADS 5 lesions on MRI | 8 | 8 |
| Histology not available | 5 | 3 |
| Prostate carcinomab | 33 | 25 |
| Atypical small acinar proliferation (ASAP)b | 6 | 3 |
| High-grade prostatic intraepithelial neoplasia (HGPIN)b | 1 | 1 |
| Prostatitisb | 14 | 9 |
aTransurethral resection of the prostate
bConfirmed after biopsy
Indications for MRI
| Micro-enema ( | No enema ( | |
|---|---|---|
| Elevated PSA levels | 54 | 40 |
| Active surveillance | 5 | 5 |
| Prior to prostatectomy | 3 | 5 |
| Suspicious DRE | 1 | 1 |
Sequence parameters of DWI
| Imaging plane | Axial |
| Echo time (ms) | 93 |
| Repetition time (ms) | 8300 |
| Field of view (mm) | 221 × 260 |
| In-plane resolution (mm × mm) | 1.625 × 1.625 × 3 |
| Slice thickness/gap (mm) | 3/3 |
| Phase encoding direction | Anterior–posterior |
| Number of signals averaged | 4 |
| Parallel imaging | iPAT mode GRAPPA |
| Acceleration factor | 2 |
| Flip angle | 90° |
| Matrix | 160 × 136 |
| Fat saturation technique | SPAIR |
| Receiver bandwidth (Hz/voxel) | 1157 |
| b values (s/mm2) | 0, 500, 1000, 1500, 2000 |
iPAT integrated parallel acquisition techniques, GRAPPA generalized autocalibrating partial parallel acquisition, SPAIR spectral attenuated inversion recovery
Fig. 1Artefact score 0 (b1000)
Fig. 2Artefact score 1 (b1000)
Fig. 3Artefact score 2 (b1000)
Fig. 4Artefact score 3 (b1000)
Results for MRI scans with and without bowel preparation
| Micro-enema ( | No enema ( | |
|---|---|---|
| Relevant artefacts (≥ 2) | ||
| Yes | 6 (9.5%) | 21 (41.2%) |
| No | 57 (90.5%) | 30 (58.8%) |
| Artefact scores | ||
| 0 | 49 (77.8%) | 16 (31.4%) |
| 1 | 8 (12.7%) | 14 (27.4%) |
| 2 | 5 (7.9%) | 18 (35.3%) |
| 3 | 1 (1.6%) | 3 (5.9%) |
Fig. 5Artefact scores in the enema versus no-enema group