Literature DB >> 32493864

Polymerization shrinkage kinetics and degree of conversion of resin composites.

Tong Xu1, Xuan Li1, Han Wang1, Gang Zheng2, Gaigai Yu1, Huimin Wang1, Song Zhu1.   

Abstract

This study compared shrinkage strain, polymerization shrinkage kinetics, and degree of conversion (DC) of a set of resin composites and investigated their influencing factors. Ten commercial resin composites were assessed, and 5 specimens (n = 5) were developed for material and subjected to light curing using light emitting diode light at 650 mW/cm2 for 40 s. The laser triangulation method was adopted to assess the shrinkage strain, and Fourier transform infrared spectroscopy was used to measure DC. The shrinkage strain was monitored for 5 min in real time and its data were subjected to differential calculations to get the shrinkage strain rate curve with respect to time, obtaining the maximum shrinkage strain rate (Rmax) and gel time. The values of shrinkage strain varied from 1.28% to 2.10%. The Rmax values were between 5.17 μm/s and 21.83 μm/s. Gel time values varied from 3.08 s to 4.32 s. The DC yielded values ranging from 53.62% to 87.01%. The values of polymerization shrinkage and DC were dependent on the composition of materials, including the monomer matrix and filler system. Compared to the micro-filler materials, the nano-filler resin composites had higher values of DC. Some resin composites are suitable for clinical applications because of their superior polymerization shrinkage properties and DC.

Entities:  

Keywords:  degree of conversion; gel time; resin composite; shrinkage strain; shrinkage strain rate

Year:  2020        PMID: 32493864     DOI: 10.2334/josnusd.19-0157

Source DB:  PubMed          Journal:  J Oral Sci        ISSN: 1343-4934            Impact factor:   1.556


  2 in total

Review 1.  The influence of inorganic fillers on the light transmission through resin-matrix composites during the light-curing procedure: an integrative review.

Authors:  Rita Fidalgo-Pereira; Daniela Carpio; Orlanda Torres; Oscar Carvalho; Filipe Silva; Bruno Henriques; Mutlu Özcan; Júlio C M Souza
Journal:  Clin Oral Investig       Date:  2022-06-29       Impact factor: 3.606

2.  Effects of Post-Curing Light Intensity on the Mechanical Properties and Three-Dimensional Printing Accuracy of Interim Dental Material.

Authors:  Min-Jung Kang; Jung-Hwa Lim; Chan-Gyu Lee; Jong-Eun Kim
Journal:  Materials (Basel)       Date:  2022-10-04       Impact factor: 3.748

  2 in total