Literature DB >> 32492235

Whole-heart, ungated, free-breathing, cardiac-phase-resolved myocardial perfusion MRI by using Continuous Radial Interleaved simultaneous Multi-slice acquisitions at sPoiled steady-state (CRIMP).

Ye Tian1,2, Jason Mendes1, Brent Wilson3, Alexander Ross3, Ravi Ranjan3, Edward DiBella1,4, Ganesh Adluru1,4.   

Abstract

PURPOSE: To develop a whole-heart, free-breathing, non-electrocardiograph (ECG)-gated, cardiac-phase-resolved myocardial perfusion MRI framework (CRIMP; Continuous Radial Interleaved simultaneous Multi-slice acquisitions at sPoiled steady-state) and test its quantification feasibility.
METHODS: CRIMP used interleaved radial simultaneous multi-slice (SMS) slice groups to cover the whole heart in 9 or 12 short-axis slices. The sequence continuously acquired data without magnetization preparation, ECG gating or breath-holding, and captured multiple cardiac phases. Images were reconstructed by a motion-compensated patch-based locally low-rank reconstruction. Bloch simulations were performed to study the signal-to-noise ratio/contrast-to-noise ratio (SNR/CNR) for CRIMP and to study the steady-state signal under motion. Seven patients were scanned with CRIMP at stress and rest to develop the sequence. One human and two dogs were scanned at rest with a dual-bolus method to test the quantification feasibility of CRIMP. The dual-bolus scans were performed using both CRIMP and an ungated radial SMS saturation recovery (SMS-SR) sequence with injection dose = 0.075 mmol/kg to compare the sequences in terms of SNR, cardiac phase resolution and quantitative myocardial blood flow (MBF).
RESULTS: Perfusion images with multiple cardiac phases in all image slices with a temporal resolution of 72 ms/frame were obtained. Simulations and in-vivo acquisitions showed CRIMP kept the inner slices in steady-state regardless of motion. CRIMP outperformed SMS-SR in slice coverage (9 over 6), SNR (mean 20% improvement), and provided cardiac phase resolution. CRIMP and SMS-SR sequences provided comparable MBF values (rest systolic CRIMP = 0.58 ± 0.07, SMS-SR = 0.61 ± 0.16).
CONCLUSION: CRIMP allows for whole-heart, cardiac-phase-resolved myocardial perfusion images without ECG-gating or breath-holding. The sequence can provide MBF if an accurate arterial input function is obtained separately.
© 2020 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  SPGR; myocardial perfusion; quantitative myocardial blood flow; radial trajectory; simultaneous multi-slice

Mesh:

Year:  2020        PMID: 32492235      PMCID: PMC7710603          DOI: 10.1002/mrm.28337

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  53 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Waren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Int J Cardiovasc Imaging       Date:  2002-02       Impact factor: 2.357

2.  Model-based registration for dynamic cardiac perfusion MRI.

Authors:  Ganesh Adluru; Edward V R DiBella; Matthias C Schabel
Journal:  J Magn Reson Imaging       Date:  2006-11       Impact factor: 4.813

3.  Temporally constrained reconstruction of dynamic cardiac perfusion MRI.

Authors:  Ganesh Adluru; Suyash P Awate; Tolga Tasdizen; Ross T Whitaker; Edward V R Dibella
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

4.  Myocardial perfusion MRI with an undersampled 3D stack-of-stars sequence.

Authors:  Liyong Chen; Ganesh Adluru; Matthias C Schabel; Chris J McGann; Edward V R Dibella
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

5.  All-systolic non-ECG-gated myocardial perfusion MRI: Feasibility of multi-slice continuous first-pass imaging.

Authors:  Behzad Sharif; Reza Arsanjani; Rohan Dharmakumar; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2015-06-06       Impact factor: 4.668

6.  Golden-ratio rotated stack-of-stars acquisition for improved volumetric MRI.

Authors:  Ziwu Zhou; Fei Han; Lirong Yan; Danny J J Wang; Peng Hu
Journal:  Magn Reson Med       Date:  2017-02-06       Impact factor: 4.668

7.  Quantitative three-dimensional cardiovascular magnetic resonance myocardial perfusion imaging in systole and diastole.

Authors:  Manish Motwani; Ananth Kidambi; Steven Sourbron; Timothy A Fairbairn; Akhlaque Uddin; Sebastian Kozerke; John P Greenwood; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2014-02-24       Impact factor: 5.364

8.  Interstudy repeatability of self-gated quantitative myocardial perfusion MRI.

Authors:  Devavrat Likhite; Promporn Suksaranjit; Ganesh Adluru; Nan Hu; Cindy Weng; Eugene Kholmovski; Chris McGann; Brent Wilson; Edward DiBella
Journal:  J Magn Reson Imaging       Date:  2015-12-13       Impact factor: 4.813

9.  Acquisition and reconstruction of undersampled radial data for myocardial perfusion magnetic resonance imaging.

Authors:  Ganesh Adluru; Chris McGann; Peter Speier; Eugene G Kholmovski; Akram Shaaban; Edward V R Dibella
Journal:  J Magn Reson Imaging       Date:  2009-02       Impact factor: 4.813

10.  Feasibility of multiple-view myocardial perfusion MRI using radial simultaneous multi-slice acquisitions.

Authors:  Ye Tian; Jason Mendes; Apoorva Pedgaonkar; Mark Ibrahim; Leif Jensen; Joyce D Schroeder; Brent Wilson; Edward V R DiBella; Ganesh Adluru
Journal:  PLoS One       Date:  2019-02-11       Impact factor: 3.240

View more
  2 in total

1.  Improved simultaneous multislice cardiac MRI using readout concatenated k-space SPIRiT (ROCK-SPIRiT).

Authors:  Omer Burak Demirel; Sebastian Weingärtner; Steen Moeller; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2021-02-10       Impact factor: 3.737

2.  Free-breathing motion-informed locally low-rank quantitative 3D myocardial perfusion imaging.

Authors:  Tobias Hoh; Valery Vishnevskiy; Malgorzata Polacin; Robert Manka; Maximilian Fuetterer; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2022-06-17       Impact factor: 3.737

  2 in total