Literature DB >> 32490835

A retrospective comparison of the conventional versus three-dimensional printed model-assisted surgery in the treatment of acetabular fractures.

Anıl Murat Öztürk1, Onur Süer1, Suzan Şirintürk2, Kemal Aktuğlu1, Figen Govsa2, Mehmet Asım Özer2.   

Abstract

OBJECTIVE: The aim of this study was to compare the clinical and radiological outcomes of the conventional versus individualized three-dimensional (3D) printing model-assisted pre-contoured plate fixation in the treatment of patients with acetabular fractures.
METHODS: The data from 18 consecutive patients who underwent surgery for the acetabular fractures were retrospectively analyzed. The patients were divided into two groups (9 in each): conventional and 3D printed model-assisted. The groups were then compared in terms of the duration of surgery, time of instrumentation, time of intraoperative fluoroscopy, and volume of blood loss. The quality of the fracture reduction was also evaluated postoperatively by radiography and computed tomography in both the groups. The quality of the fracture reduction was defined as good (<2 mm) or fair (>2 mm) based on the amount of displacement in the acetabulum.
RESULTS: The conventional group included 9 patients (9 males; mean age=41.7 years; age range=16-70) with a mean follow-up of 11.9 months (range=8-15); the 3D printed model-assisted group consisted of 9 patients (9 males; mean age=46.2 years; age range=30-66) with a mean follow-up of 10.33 months (range=7-17). The average duration of surgery, mean time of instrumentation, time of intraoperative fluoroscopy, and mean volume of blood loss were 180.5±9 minutes, 36.2±3.6 minutes, 6±1 times, and 403.3±52.7 mL in the 3D printed model-assisted group, and 220±15.6 minutes, 57.4±10.65 minutes, 10.4±2.2 times, and 606.6±52.7 mL in the conventional group, respectively. Procedurally, the average duration of surgery, mean time of instrumentation, and mean time of fluoroscopy were significantly shorter, and the mean volume of blood loss was significantly lower in the 3D printed model-assisted group (p<0.05). The quality of the fracture reduction was good in 7 patients (78%) in the conventional group and 8 patients (89%) in the 3D printed model-assisted group.
CONCLUSION: As compared with the conventional surgery, the 3D printing model-assisted pre-contoured plate fixation technique can improve the clinical and radiological outcomes of the acetabular fractures, with shorter surgery, instrumentation, intraoperative fluoroscopy times, and blood loss. LEVEL OF EVIDENCE: Level III, Therapeutic study.

Entities:  

Mesh:

Year:  2020        PMID: 32490835      PMCID: PMC7444883          DOI: 10.5152/j.aott.2020.19054

Source DB:  PubMed          Journal:  Acta Orthop Traumatol Turc        ISSN: 1017-995X            Impact factor:   1.511


  31 in total

Review 1.  Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

Authors:  Mehdi Boudissa; Aurélien Courvoisier; Matthieu Chabanas; Jérôme Tonetti
Journal:  Expert Rev Med Devices       Date:  2017-12-10       Impact factor: 3.166

2.  Evaluation of accuracy of virtual surgical planning for patient-specific pre-contoured plate in acetabular fracture fixation.

Authors:  Lalit Maini; Tarun Verma; Amit Sharma; Ankur Sharma; Abhishek Mishra; Sunil Jha
Journal:  Arch Orthop Trauma Surg       Date:  2018-01-24       Impact factor: 3.067

3.  Application of 3D printing for treating fractures of both columns of the acetabulum: Benefit of pre-contouring plates on the mirrored healthy pelvis.

Authors:  P Upex; P Jouffroy; G Riouallon
Journal:  Orthop Traumatol Surg Res       Date:  2017-02-02       Impact factor: 2.256

4.  Three-dimensional printing and patient-specific pre-contoured plate: future of acetabulum fracture fixation?

Authors:  L Maini; A Sharma; S Jha; A Sharma; A Tiwari
Journal:  Eur J Trauma Emerg Surg       Date:  2016-10-26       Impact factor: 3.693

5.  Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery.

Authors:  Fangyang Shen; Bailiang Chen; Qingshan Guo; Yue Qi; Yue Shen
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-06-30       Impact factor: 2.924

6.  The design, production and clinical application of 3D patient-specific implants with drilling guides for acetabular surgery.

Authors:  B J Merema; J Kraeima; K Ten Duis; K W Wendt; R Warta; E Vos; R H Schepers; M J H Witjes; F F A IJpma
Journal:  Injury       Date:  2017-08-30       Impact factor: 2.586

Review 7.  High-energy pediatric pelvic and acetabular fractures.

Authors:  Louis F Amorosa; Peter Kloen; David L Helfet
Journal:  Orthop Clin North Am       Date:  2014-10       Impact factor: 2.472

8.  Navigation system for robot-assisted intra-articular lower-limb fracture surgery.

Authors:  Giulio Dagnino; Ioannis Georgilas; Paul Köhler; Samir Morad; Roger Atkins; Sanja Dogramadzi
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-28       Impact factor: 2.924

9.  Digital anatomical measurements and crucial bending areas of the fixation route along the inferior border of the arcuate line for pelvic and acetabular fractures.

Authors:  Chun Bi; Xiaoxi Ji; Fang Wang; Dongmei Wang; Qiugen Wang
Journal:  BMC Musculoskelet Disord       Date:  2016-03-15       Impact factor: 2.362

10.  Laparoscopic Acetabular Fracture Fixation after Three-dimensional Modelling and Printing.

Authors:  Can-Jun Zeng; Wen-Hua Huang; Hua-Jun Huang; Zhang-Lin Wu
Journal:  Indian J Orthop       Date:  2017 Sep-Oct       Impact factor: 1.251

View more
  3 in total

1.  Influence of direct radiography in decision making during orthopaedic trauma surgery: A prospective study.

Authors:  Ibrahim Alper Yavuz; Utku Gurhan; Erman Ceyhan; Fatih Inci; Ozdamar Fuad Oken; Ahmet Ozgur Yildirim; Ozlem Ozkale Yavuz
Journal:  J Orthop       Date:  2022-10-07

2.  A Systematic Review and Meta-Analysis of 3D Printing Technology for the Treatment of Acetabular Fractures.

Authors:  Jin Cao; Huanye Zhu; Chao Gao
Journal:  Biomed Res Int       Date:  2021-08-17       Impact factor: 3.411

3.  Traditional versus mirror three-dimensional printing technology for isolated acetabular fractures: a retrospective study with a median follow-up of 25 months.

Authors:  Kai Xiao; Bo Xu; Lin Ding; Weiguang Yu; Lei Bao; Xinchao Zhang; Meiji Chen; Xiangzhen Liu; Huanyi Lin; Tengfei Li
Journal:  J Int Med Res       Date:  2021-06       Impact factor: 1.671

  3 in total