Literature DB >> 32486770

Sensitivity to binaural temporal-envelope beats with single-sided deafness and a cochlear implant as a measure of tonotopic match (L).

Coral E Dirks1, Peggy B Nelson1, Matthew B Winn1, Andrew J Oxenham2.   

Abstract

For cochlear-implant users with near-normal contralateral hearing, a mismatch between the frequency-to-place mapping in the two ears could produce a suboptimal performance. This study assesses tonotopic matches via binaural interactions. Dynamic interaural time-difference sensitivity was measured using bandpass-filtered pulse trains at different rates in the acoustic and implanted ear, creating binaural envelope beats. Sensitivity to beats should peak when the same tonotopic region is stimulated in both ears. All nine participants detected dynamic interaural timing differences and demonstrated some frequency selectivity. This method provides a guide to frequency-to-place mapping without compensation for inherent latency differences between the acoustic and implanted ears.

Entities:  

Mesh:

Year:  2020        PMID: 32486770      PMCID: PMC7253218          DOI: 10.1121/10.0001305

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  22 in total

1.  The influence of carrier level and frequency on modulation and beat-detection thresholds for sinusoidal carriers

Authors: 
Journal:  J Acoust Soc Am       Date:  2000-08       Impact factor: 1.840

2.  Frequency map for the human cochlear spiral ganglion: implications for cochlear implants.

Authors:  Olga Stakhovskaya; Divya Sridhar; Ben H Bonham; Patricia A Leake
Journal:  J Assoc Res Otolaryngol       Date:  2007-02-21

3.  The consequences of neural degeneration regarding optimal cochlear implant position in scala tympani: a model approach.

Authors:  Jeroen J Briaire; Johan H M Frijns
Journal:  Hear Res       Date:  2006-03-07       Impact factor: 3.208

4.  Human interaural time difference thresholds for sine tones: the high-frequency limit.

Authors:  Andrew Brughera; Larisa Dunai; William M Hartmann
Journal:  J Acoust Soc Am       Date:  2013-05       Impact factor: 1.840

5.  Rotating tones and binaural beats.

Authors:  D R Perrott; A D Musicant
Journal:  J Acoust Soc Am       Date:  1977-05       Impact factor: 1.840

6.  Pitch adaptation patterns in bimodal cochlear implant users: over time and after experience.

Authors:  Lina A J Reiss; Rindy A Ito; Jessica L Eggleston; Selena Liao; Jillian J Becker; Carrie E Lakin; Frank M Warren; Sean O McMenomey
Journal:  Ear Hear       Date:  2015 Mar-Apr       Impact factor: 3.570

7.  Localization of sound in rooms, III: Onset and duration effects.

Authors:  B Rakerd; W M Hartmann
Journal:  J Acoust Soc Am       Date:  1986-12       Impact factor: 1.840

8.  Restoration of spatial hearing in adult cochlear implant users with single-sided deafness.

Authors:  Ruth Y Litovsky; Keng Moua; Shelly Godar; Alan Kan; Sara M Misurelli; Daniel J Lee
Journal:  Hear Res       Date:  2018-04-14       Impact factor: 3.208

9.  Spatial Speech-in-Noise Performance in Bimodal and Single-Sided Deaf Cochlear Implant Users.

Authors:  Ben Williges; Thomas Wesarg; Lorenz Jung; Leontien I Geven; Andreas Radeloff; Tim Jürgens
Journal:  Trends Hear       Date:  2019 Jan-Dec       Impact factor: 3.293

10.  Comparison of Interaural Electrode Pairing Methods for Bilateral Cochlear Implants.

Authors:  Hongmei Hu; Mathias Dietz
Journal:  Trends Hear       Date:  2015-12-01       Impact factor: 3.293

View more
  5 in total

Review 1.  Considerations for Fitting Cochlear Implants Bimodally and to the Single-Sided Deaf.

Authors:  Sabrina H Pieper; Noura Hamze; Stefan Brill; Sabine Hochmuth; Mats Exter; Marek Polak; Andreas Radeloff; Michael Buschermöhle; Mathias Dietz
Journal:  Trends Hear       Date:  2022 Jan-Dec       Impact factor: 3.496

2.  A Comparison of Place-Pitch-Based Interaural Electrode Matching Methods for Bilateral Cochlear-Implant Users.

Authors:  Kenneth K Jensen; Stefano Cosentino; Joshua G W Bernstein; Olga A Stakhovskaya; Matthew J Goupell
Journal:  Trends Hear       Date:  2021 Jan-Dec       Impact factor: 3.293

3.  No Benefit of Deriving Cochlear-Implant Maps From Binaural Temporal-Envelope Sensitivity for Speech Perception or Spatial Hearing Under Single-Sided Deafness.

Authors:  Coral E Dirks; Peggy B Nelson; Andrew J Oxenham
Journal:  Ear Hear       Date:  2022 Mar/Apr       Impact factor: 3.562

4.  Interaural Place-of-Stimulation Mismatch Estimates Using CT Scans and Binaural Perception, But Not Pitch, Are Consistent in Cochlear-Implant Users.

Authors:  Joshua G W Bernstein; Kenneth K Jensen; Olga A Stakhovskaya; Jack H Noble; Michael Hoa; H Jeffery Kim; Robert Shih; Elizabeth Kolberg; Miranda Cleary; Matthew J Goupell
Journal:  J Neurosci       Date:  2021-11-01       Impact factor: 6.709

5.  Frequency Fitting Optimization Using Evolutionary Algorithm in Cochlear Implant Users with Bimodal Binaural Hearing.

Authors:  Alexis Saadoun; Antoine Schein; Vincent Péan; Pierrick Legrand; Ludwig Serge Aho Glélé; Alexis Bozorg Grayeli
Journal:  Brain Sci       Date:  2022-02-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.