Benan Dursunoğlu 1 , Hafize Yuca 1 , Zühal Güvenalp 1 , Sefa Gözcü 2 , Bilal Yilmaz 3 . Show Affiliations »
Abstract
OBJECTIVES: The aim of our study was to develop a simple, precise, sensitive and specific method for the simultaneous determination of arbutin and hydroquinone in different herbal slimming products using GC-MS. MATERIALS AND METHODS: The methanol and aqueous extracts of nine herbal slimming products in Turkey were evaluated for analysis of arbutin and hydroquinone using GC-MS method. RESULTS: The retention times of arbutin and hydroquinone were found as 11.32 and 5.44 min, respectively. The linear ranges in this method were 5-500 ng/mL for arbutin and hydroquinone, respectively. The intra- and inter-day precisions, expressed as the relative standard deviation, were less than 1.94 and 2.73%, determined from quality control samples for arbutin and hydroquinone, and accuracy was within 1.13 and 2.56% in terms of relative error, respectively. The limit of detection and quantification were 0.555 and 1.665 ng/mL for arbutin, and 0.031 and 0.093 ng/mL for hydroquinone, respectively. CONCLUSION: The developed method can be used for routine quality control analysis of arbutin and hydroquinone in different herbal slimming products. ©Copyright 2018 Turk J Pharm Sci, Published by Galenos Publishing House.
OBJECTIVES: The aim of our study was to develop a simple, precise, sensitive and specific method for the simultaneous determination of arbutin and hydroquinone in different herbal slimming products using GC-MS. MATERIALS AND METHODS: The methanol and aqueous extracts of nine herbal slimming products in Turkey were evaluated for analysis of arbutin and hydroquinone using GC-MS method. RESULTS: The retention times of arbutin and hydroquinone were found as 11.32 and 5.44 min, respectively. The linear ranges in this method were 5-500 ng/mL for arbutin and hydroquinone, respectively. The intra- and inter-day precisions, expressed as the relative standard deviation, were less than 1.94 and 2.73%, determined from quality control samples for arbutin and hydroquinone, and accuracy was within 1.13 and 2.56% in terms of relative error, respectively. The limit of detection and quantification were 0.555 and 1.665 ng/mL for arbutin, and 0.031 and 0.093 ng/mL for hydroquinone, respectively. CONCLUSION: The developed method can be used for routine quality control analysis of arbutin and hydroquinone in different herbal slimming products. ©Copyright 2018 Turk J Pharm Sci, Published by Galenos Publishing House.
Entities: Chemical
Keywords:
Arbutin; Calluna vulgaris; GC-MS; herbal slimming products; hydroquinone
Year: 2018
PMID: 32454673 PMCID: PMC7227836 DOI: 10.4274/tjps.38258
Source DB: PubMed Journal: Turk J Pharm Sci ISSN: 1304-530X