Mads Jochumsen1, Hendrik Knoche2, Troels Wesenberg Kjaer3, Birthe Dinesen1, Preben Kidmose4.
Abstract
Brain-computer interfaces (BCIs) can be used in neurorehabilitation; however, the literature about transferring the technology to rehabilitation clinics is limited. A key component of a BCI is the headset, for which several options are available. The aim of this study was to test four commercially available headsets' ability to record and classify movement intentions (movement-related cortical potentials-MRCPs). Twelve healthy participants performed 100 movements, while continuous EEG was recorded from the headsets on two different days to establish the reliability of the measures: classification accuracies of single-trials, number of rejected epochs, and signal-to-noise ratio. MRCPs could be recorded with the headsets covering the motor cortex, and they obtained the best classification accuracies (73%-77%). The reliability was moderate to good for the best headset (a gel-based headset covering the motor cortex). The results demonstrate that, among the evaluated headsets, reliable recordings of MRCPs require channels located close to the motor cortex and potentially a gel-based headset.Entities:
Keywords: brain–computer interface; movement intention; movement-related cortical potential; neurorehabilitation
Mesh:
Year: 2020 PMID: 32423133 PMCID: PMC7287803 DOI: 10.3390/s20102804
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1Overview of the four headsets and the electrode types. (A): cEEGrid from TMSi. The inset shows the sensor array and the double-sided adhesive tape. The channel in the upper part of the “C” when mounted is channel 1, and the channel numbers ascend clockwise on the electrode. (B): MyndBand from MyndPlay. The inset shows the dry electrode and the Bluetooth unit that transmits the data. (C): Quick-Cap from Compumedics. The inset shows the electrode type that is mounted in the cap. (D): Water-based headset from TMSi. The inset shows the electrode house and the felt insert.
Figure 2Grand average across participants for each headset and each day. “0 s” is the task onset. For the Quick-Cap and water-based electrodes, Cz was used, whereas channel 2 was used for the cEEGrid and the single electrode on the forehead for the MyndBand.
Results of the signal quality analyses for the four headsets. The signal-to-noise ratio (SNR), average amplitude around the movement onset, number of rejected epochs, and number of rejected participants are presented for both experimental sessions. The results are presented based on Cz (water-based electrodes and Quick-Cap) or the channel closest to that (MyndBand and cEEGrid).
| SNR | Amplitude (µV) | # Rejected Epochs | # Excluded Participants | |||||
|---|---|---|---|---|---|---|---|---|
| Day 1 | Day 2 | Day 1 | Day 2 | Day 1 | Day 2 | Day 1 | Day 2 | |
| cEEGrid | 0.8/1.2/1.4 | 0.6/0.9/1.6 | −4.9/−0.8/0.9 | −3.6/−1.6/0.6 | 2/6/65 | 1/3/7 | 2 | 0 |
| MyndBand | 0.6/0.9/1.1 | 0.7/0.8/0.9 | −0.7/0.3/0.9 | −0.6/0.2/0.6 | 7/19/45 | 18/28/36 | 2 | 1 |
| Quick-Cap | 1.1/1.5/2.5 | 1.4/1.7/2.2 | −3.4/−2.6/−0.9 | −2.6/−1.0/0.0 | 0/1/2 | 0/0/2 | 0 | 0 |
| Water-based | 0.8/1.3/2.0 | 1.0/1.4/2.7 | −7.4/−2.9/1.9 | −4.3/−2.7/−0.3 | 2/2/6 | 2/3/9 | 0 | 0 |
| 25% / Median / 75% | ||||||||
Figure 3Boxplots with quartiles for the signal quality analyses. (a): Average amplitude around the movement onset; (b): Signal-to-noise ratio; (c): Number of rejected epochs for a single channel.
Figure 4Boxplots with quartiles for the classification accuracies (a) and number of rejected epochs (b).
Results of the classification analyses for the four headsets. The classification accuracy and number of rejected epochs are presented for both experimental sessions. The results are based on all available channels; therefore, the number of rejected epochs differ from Table 1, which was based on a single channel.
| Classification Accuracy (%) | # Rejected Epochs | # Excluded Participants | ||||
|---|---|---|---|---|---|---|
| Day 1 | Day 2 | Day 1 | Day 2 | Day 1 | Day 2 | |
| cEEGrid | 48/56/70 | 55/60/63 | 0/7/54 | 0/1/3 | 2 | 0 |
| MyndBand | 49/56/59 | 50/56/60 | 19/31/85 | 31/39/70 | 3 | 2 |
| Quick-Cap | 70/77/82 | 69/74/78 | 0/1/1 | 0/1/1 | 0 | 0 |
| Water-based | 64/73/78 | 65/72/75 | 0/3/88 | 0/63/100 | 3 | 4 |
| 25% / Median / 75% | ||||||
Test–retest reliability of the signal-to-noise ratio (SNR), average amplitude around the movement onset and the classification accuracies.
| Intraclass Correlation Coefficient (ICC) | |||
|---|---|---|---|
| ICC_SNR | ICC_Amplitude | ICC_Classification Accuracy | |
| cEEGrid | −0.3 | 0.32 | 0.63 |
| MyndBand | 0.43 | −0.21 | 0.33 |
| Quick-Cap | 0.78 | 0.83 | 0.59 |
| Water-based | −0.29 | 0.06 | −0.11 |