| Literature DB >> 32419040 |
Miguel A De Gregorio1, Jose A Guirola2, Jose Urbano3, Ignacio Díaz-Lorenzo4, Jose J Muñoz5, Elena Villacastin6, Antonio Lopez-Medina7, Ana L Figueredo8, Javier Guerrero9, Sergio Sierre10, Javier Blazquez Sanchez11, William T Kuo12, David Jimenez13.
Abstract
BACKGROUND: The treatment of venous thromboembolic disease the treatment of choice is systemic anticoagulation. However, the interruption of the inferior vena cava with filters has been recommended when anticoagulation fails or there is a contraindication. Due to the rising inferior vena cava filter (IVCF) complications, physicians are encouraged to retrieve them when there is no longer recommended. In daily practice, it may be a difficult close follow-up of these patients. In this study, the primary objective was to evaluate the IVCF retrieval rate of all implanted filters in a Spanish registry. Secondary objectives were to analyze the causes of failed retrieval, procedure-related complications, and outcomes at a 12-month follow-up.Entities:
Keywords: Inferior vena cava filters; Retrievable filters; Venous thrombotic disease (VTD)
Year: 2020 PMID: 32419040 PMCID: PMC7231811 DOI: 10.1186/s42155-020-00114-5
Source DB: PubMed Journal: CVIR Endovasc ISSN: 2520-8934
Registry form. Data points included in the registry
| Identification | Number |
| Sex | |
| Age | |
| Risk factors | |
| Filter indication | |
| Technical data | Access |
| Filter type | |
| Filter implantation date | |
| Recovery attemps | 1,2,3 … |
| Death before recovery | Yes /NO |
| Anticoagulant treatment | Yes /NO |
| Recovery access | Yugular vein (R/L) |
| Femoral vein (R/L) | |
| Others | |
| Recovery with manufacturer recommended set | Set recommended by the manufacturer |
| Recovery with other maneuvers | Snare, ballooms, cocodrile clips, grasping |
| Cause of inability to filter recover | Tilt, leg penetration, fibrosis, thrombosis, death, others |
| Follow-up | 3, 6, 12 months |
| Recurrence pulmonary embolism, other causes |
The main indication for Inferior Vena Cava Filters
| Indications | Direct cause | n | N | % |
|---|---|---|---|---|
| Prevention in high risk patients with DVT | - EP massive treated with fibrinolysis o thrombectomy | 54 | 120 | 33,7 |
| - Iliofemoral DVT | 49 | |||
| - COPD + DVT | 17 | |||
| Contraindication for anticoagulation | - Recente bleeding | 104 | 188 | 52,8 |
| - Recent surgery | 42 | |||
| - Brain tumor /Recent stroke | 27 | |||
| - Severe trauma | 15 | |||
| Recurrence of pulmonary embolism while receiving anticoagulation | 48 | 13,4 |
Fig. 1Diagram showing the distribution of inferior vena cava filters. Filters retrieved successfully and unable to retrieve filters with their causes
Days until the filter was retrieved in each type of filter, either satisfactorily or failed as well as the range (maximum and minimum days for each type of filter)
| Filter (356) | N | % | Mean days until retrieval | Range days | p | ||
|---|---|---|---|---|---|---|---|
| Successful | Failed | Min | Max | ||||
| Gunther Tulip (Cook) | 160 | 44,9 | 146/64,6 | 2/87,5 | 1 | 2920 | < 0.01 |
| Optease (Cordis) | 77 | 21,6 | 44/29,1 | 11/48,09 | 12 | 98 | < 0.01 |
| Celect (Cook) | 49 | 13,7 | 42/ 41,1 | 2/151 | 19 | 270 | < 0.01 |
| Aegisy (Lifetech | 33 | 9,2 | 20/14,9 | 1/13 | 11 | 27 | 0.05 |
| Option ELITE (Argon) | 16 | 4,4 | 11/32,3 | 1/28 | 26 | 41 | 0.01 |
| Denali (Bard) | 11 | 3,08 | 8/31 | 0/0 | 26 | 35 | 0.04 |
| ALN Filter (ALN) | 10 | 2,8 | 8/32,3 | 0/0 | 26 | 366 | 0.04 |
| TOTAL | 356 | 1 | 2920 | ||||
Distribution by type of filter (Successful withdrawal or failure, as well as filters that could not be removed because the patient died during their hospital stay or for various reasons, were left as permanent filters)
| Filter | N | % | Successful | Failed | Dead* | Permanent | p |
|---|---|---|---|---|---|---|---|
| Gunther Tulip (Cook) | 160 | 44,9 | 146 /91,2% | 2/1,2% | 9/5,6% | 2/1,2 | < 0.01 |
| Optease (Cordis) | 77 | 21,6 | 42/54,5% | 11/14,2% | 6/7,7% | 17/22,0% | < 0.01 |
| Celect (Cook) | 49 | 13,7 | 42/85,7% | 2/4,0% | 2/4,0% | 2/4,0% | < 0.01 |
| Aegisy (Lifetech | 33 | 9,2 | 20/60,6% | 1/3,0% | 3/9,0% | 12/36,3% | < 0.1 |
| Option ELITE (Argon) | 16 | 4,4 | 11/68,7% | 1/6,25% | 1/6,2% | 4/25% | 0.05 |
| Denali (Bard) | 11 | 3,08 | 7/63,6% | 0/0 | 1/9,0% | 3/27,7% | 0.04 |
| ALN Filter (ALN) | 10 | 2,8 | 6/60% | 0/0 | 2/20 | 1/10% | 0.04 |
| 356 | 274 | 17 | 24 | 41 |
* Patients died before inferior vena cava filter was scheduled for retrieval
Fig. 2Example of IVCF retrieval with difficulty. A 61-year-old female patient diagnosed with multiple myeloma. Six years ago she had DVT in her left lower limb. She was treated with unfractionated heparin and had an upper-GI bleed, and anticoagulants became contraindicated. An Optease filter was implanted infrarenal. a. abdominal x-ray showed the Optease filter in a proper position. b. Abdominal CT with sagittal MPR showed the filter slightly tilted on the vertical axis. c. Femoral access with a 16 Fr sheath and a 25 mm snare (Amplatz GooseNet snare). After several attempts, it was impossible to recover it. d. Jugular access was made with a 12 F sheath and a guide was passed through the upper vertex of the filter and with several movements from both accesses, the IVCF was introduced into the sheath and the filter could be recovered. e. Cavography after filter retrieval (shows endothelial alteration). f. The filter recovered with endothelial remains
Main causes of IVCF recovery failure and number retrieval attempts
| Filter | N | Failed | Reasons for failed | Recovery Attemps |
|---|---|---|---|---|
| Gunther Tulip (Cook) | 160 | 2/1,2% | -Tilt> 15°, Hook included in IVC wall | 2 |
| - Hook and legs included in IVC wall | 3 | |||
| Optease (Cordis) | 77 | 11/14,2% | - Legs and structures included in IVC wall | 2 (5 pats) |
| - Legs and structures included in IVC wall | 1 (6 pats.) | |||
| Celect (Cook) | 49 | 2/4,0% | -Tilt> 15°, Hook included in IVC wall | 2 |
| - Tilt> 15°, Hook included in IVC wall | 1 | |||
| Aegisy (Lifetech) | 33 | 1/3,0% | - Legs and structures included in IVC wall | 1 |
| Option ELITE (Argon) | 16 | 1/6,25% | -Tilt> 15°, Hook included in IVC wall | 2 |
| Denali (Bard) | 11 | 0/0 | – | |
| ALN Filter (ALN) | 10 | 0/0 | – | |
| 356 | 17 |
(Pats: Patients)
Fluoroscopy time and Air Kerma data for retrieval procedure (successful and failed filter retrieval)
| Recovery | Fluoroscopy time Minutes | Air Kerma mGy | p | |
|---|---|---|---|---|
| Successful | Mean | 13,7 | 395,2 | < 0.01 |
| SD | 11,6 | 505,7 | ||
| Max | 33,1 | 1796,1 | ||
| Min | 2,5 | 94,7 | ||
| Failed | Mean | 41,9 | 1641,7 | < 0.01 |
| SD | 11 | 421 | ||
| Max | 64 | 2117,2 | ||
| Min | 25,4 | 1314,9 |